Heat & Glo • SL-550 / 750 / 950TV-IPI-E • 2119-900 Rev. H • 11/08
7
B. Tempered Glass Specifi cations
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous loca-
tions such as bathtub enclosures as defi ned by the Con-
sumer Product Safety Commission (CPSC). The tempered
glass has been tested and certifi ed to the requirements
of
ANSI Z97.1
and
CPSC 16 CFR 1202
(Safety Glazing
Certifi cation Council
SGCC# 1595
and
1597
. Architectur-
al Testing, Inc. Reports
02-31919.01
and
02-31917.01
).
This statement is in compliance with
CPSC 16 CFR Sec-
tion 1201.5
“Certifi cation and labeling requirements”
which refers to
15
U.S. Code
(USC) 2063
stating “…Such
certifi cate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
C. BTU Specifi cations
A. Appliance Certifi cation
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
1
1
Listing and Code Approvals
MODELS: SL-550TV-IPI-E, SL-750TV-IPI-E, SL-950TV-IPI-E
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: B-Vent Decorative
STANDARD: ANSI Z21.50-2007 • CSA 2.22-2007
Model(s)
U.S. (0-2000 ft.) or Canada (2000-4500 ft.)
Maximum
Input BTU/h
Minimum
Input BTU/h
Orifi ce
Size
(DMS)
SL-550TV-IPI-E
US
21,100
14,700
44
CAN
18,990
13,230
45
SL-550TV-IPI-E (LP)
US
20,000
14,300
55
CAN
18,000
12,870
56
SL-750TV-IPI-E
US
24,800
17,700
42
CAN
22,320
15,930
43
SL-750TV-IPI-E (LP)
US
23,200
17,300
54
CAN
20,880
15,570
55
SL-950TV-IPI-E
US
30,900
21,300
37
CAN
27,810
19,170
38
SL-950TV-IPI-E (LP)
US
30,700
22,500
52
CAN
27,630
20,250
53
This product is listed to ANSI standards for “Vented Gas
Fireplaces” and “Gas Fired Appliances for Use at High
Altitudes”.
May be installed in a sleeping room when the provisions
for combustion, ventilation and dilution air are met per the
requirements of
ANSI 223.1/NFPA 54 National Fuel Gas
Code
. In Canada, installation in a sleeping room requires
installation with a thermostat certifi ed for use with this prod-
uct. Consult your local authorities having jurisdiction.
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
This model (natural gas and propane) can be installed in
a bedroom (in Canada) if a thermostat (
Model WH-STAT
)
is installed with the unit. Consult local code authorities.
Detailed installation instructions for Model WH-STAT are
included with the kit.