21
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. H • 9/06
A. Recommendation for Wire
This appliance requires 110-120 VAC be wired to the
junction box either for use of optional accessories (stand-
ing pilot ignition) or for proper operation of the appliance
(Intellifi re ignition). Refer to Figure 10.1 to determine if the
appliance uses an Intellifi re ignition system or Standing
Pilot ignition system.
Open the control access panel to view wiring system and
gas valve. If this appliance has a red or black ignitor button
(as noted in Figure 10.1) this appliance has a Standing Pilot
ignition system. If there is no red or black ignitor button,
this appliance has an Intellifi re ignition system.
Electrical Information
10
NOTE:
This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with
National Electric Code ANSI/NFPA 70-latest
edition
or the
Canadian Electric Code, CSA C221.1
.
C. Intellifi re Ignition System Wiring
This appliance requires a 110 VAC supply to the appliance
junction box for operation. A wiring diagram is shown in
Figure 10.2.
This appliance is equipped with an Intellifi re control valve
which operates on a 3 volt system.
This appliance is supplied with a battery pack and a 3 volt
AC transformer, which requires the installation of the sup-
plied junction box. It is highly recommended that the junc-
tion box be installed at this time to avoid reconstruction.
The battery pack requires two D cell batteries (not
included).
B. Connecting to the Appliance
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
• Incorrect wiring will damage millivolt valves.
• Incorrect wiring will override IPI safety lockout
and may cause explosion.
CAUTION
Battery polarity must be correct or module damage will occur.
Optional Accessories Requirements
Wiring for optional accessories should be done now to
avoid reconstruction.
• This appliance MUST be used with a wall switch or a
remote control.
• If using thermostat use one compatible with a millivolt
gas valve system.
• Follow parameters for locating thermostat (see individual
thermostat instructions) to ensure proper operation of
appliance.
Figure 10.1 Standing Pilot Ignition
CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Shock hazard.
• Replace damaged wire with type 105º C rated wire.
• Wire must have high temperature insulation.
• Use low resistance thermostat wire for wiring from igni-
tion system to the wall switch and thermostat.
• Keep wire lengths short as possible by removing any
excess wire length.
• Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
NOTE:
Batteries cannot be placed in the battery pack
while using the 3 volt AC transformer. The transformer
must be unplugged if the battery pack is used or battery
life will be reduced.
WARNING
WARNING