Heat & Glo • SL-550 / 750 / 950TR-D • 2044-985 Rev. J • 6/06
43
Installing the Trim
Combustible materials may be brought up to the specified
clearances on the side and top front edges of the appliance,
but
MUST NEVER
overlap onto the front face. The joints
between the finished wall and the appliance top and sides
can only be sealed with a 300° F. (149° C) minimum sealant.
WARNING: WHEN FINISHING THE APPLIANCE,
NEVER OBSTRUCT OR MODIFY THE AIR INLET/
OUTLET GRILLES IN ANY MANNER.
Install optional marble and brass trim surround kits as
desired. Marble, brass, brick, tile, or other non-combustible
materials can be used to cover up the gap between the
sheet rock and the appliance.
Do not obstruct or modify the air inlet/outlet grilles. When
overlapping on both sides, leave enough space so that the
bottom grille can be opened and the trim door removed.
!
Step 10. Installing Trim, Logs and Ember
Material, and Removing Shipping Support
Placing the Ember Material
Ember material is shipped with this gas appliance. The bag
labeled Glowing Ember (050-721) is standard glowing ember
material. To place the ember material:
•
Remove the top louver by lifting it up and away from the unit.
•
Unlatch the latches at the top and bottom of the glass door.
•
Remove the glass door from the unit (see Figure 40).
•
Place dime size pieces of ember material about 1/2 inch
apart near port holes in burner top. Do NOT press em-
bers into burner ports. Cover the top of the burner with a
single layer of ember material. For best performance do
NOT place embers on the ports at the rear of the burner
(see Figure 41).
•
Save the remaining ember materials for use during ap-
pliance servicing. The bag of embers provided is suffi-
cient for 3 to 5 applications.
•
Reinstall and latch the glass door and top louver on the unit.
CAUTION: THE GLASS DOOR MUST BE SECURELY
LATCHED BEFORE OPERATING THE UNIT.
Figure 40. Glass Assembly
Positioning the Logs
If the gas logs have been factory installed they should not
need to be positioned. If the logs have been packaged
separately, refer to the instructions that accompany the
logs.
Save the log instructions with this manual.
If sooting occurs, the logs might need to be repositioned
slightly to avoid excessive flame impingement.
GLASS SPECIFICATIONS:
SL-950TR-D
TEMPERED
SL-750TR-D
TEMPERED
SL-550TR-D
TEMPERED
___________________________________________
___________________________________________
___________________________________________
Shutter Settings
NG
LP
SL-550TR-D
1/4”
3/8”
SL-750TR-D
1/4”
3/8”
SL-950TR-D
3/8”
Full Open
LATCHES
(BOTH TOP
AND BOTTOM)
GLASS