Heat & Glo • RED40-NNN,RED40-NM, RED40-LM, RED40-NNN, RED40ST-LM, RED40ST-NM Installation Manual • 2155-975 Rev. E • 12/14
42
Figure 9.5 Air Shutter
E. Air Shutter Setting
Air shutter settings may be adjusted by a quali
fi
ed install-
er at the time of installation. The air shutter is set at the
factory for minimum vertical vent run. Adjust air shutter for
longer vertical runs. See Figure 9.5.
• Loosen the 1/4 in. screw.
• Twist shutter to adjust.
• Shutter may be open for longer horizontal vent runs.
• Do not close the air shutter more than 1/16 in. for NG or
1/4 in. for propane.
• Tighten the screw.
NOTICE:
If sooting occurs, provide more air by opening
the air shutter.
Air Shutter Settings
RED40/RED40ST
NG
PROPANE
GRANITE KIT
1/16 in.
1/4 in.
LIGHT KIT
1/16 in.
1/4 in.
PORCELAIN KIT
1/16 in.
1/4 in.