Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14
42
Figure 12.2 IPI Wiring Diagram
ACCENT LIGHT #1
ACCENT LIGHT #2
EMBER BULBS (1-4)
TO JUNCTION
BOX (110-120 VAC)
MODULE
I
S
FLAME
SENSE
IGNITER
RC300 4.5V DC
(AAA X 3)
TO JUNCTION BOX
110-120 VAC
DO NOT USE AUX2 FOR LIGHT CONNECTION
PROTECTIVE COVER INCLUDED
GROUND
ORANGE
(PILOT)
GREEN
(MAIN)
BROWN
BLACK
RED
AUX300 MODULE
AUX 1
AUX 2
FAN
ORG
WHT