Heat & Glo • Cosmo-SXT-IPI, Cosmo-GXT-IPI • 2203-900 Rev. E • 1/10
CAUTION
ALL vent specifi cations MUST be followed.
• This product is tested and listed to these specifi cations.
• Appliance performance will suffer if specifi cations are not
followed.
EXHAUST VENT PIPE
TERMINATION CAP
ADAPTOR
INSULATION SEAL
V = 14 ft. MIN.
50 ft. MAX.
INLET VENT AIR PIPE
Figure 5.1
C. Measuring Standards
Vertical measurements listed in the vent diagram (Figure
5.1) were made using the following standard:
• Vertical terminations are measured to top of chimney.
Fire Hazard.
Explosion Risk.
Asphyxiation Risk.
Do NOT connect this gas appliance to a
chimney fl ue serving a separate solid fuel or
gas burning appliance.
• May impair safe operation of this appliance
or other appliances connected to the fl ue.
• Vent this appliance directly outside.
• Use separate vent system for this appliance.
B. Horizontal Venting
Horizontal venting is NOT allowed.
5
5
Vent Information and Diagrams
A. Vent Table Key
The abbreviations listed in this vent table key are used in
the vent diagrams.
Symbol
Description
V
MIN
Minimum Vertical Run Length 14 ft.
V
MIN
Maximum Vertical Run Length 50 ft.