31
Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
A. Vent Collar Preparation
6
6
Appliance Preparation
Figure 6.2 Remove the seal cap.
(Generic Fireplace Shown)
1. Remove the seal cap as shown in Figure 6.2.
2. Locate the fiberglass gasket in the manual bag. Attach
the gasket to the outer wrap using two self-tapping
screws. This creates a seal between the first vent
component and the outer fireplace wrap. Figure 6.3
shows the gasket in place.
3. Secure the first section of venting to the firebox by at
-
taching to the starting collar with screws. See Figure
6.4.
Figure 6.1 Seal Cap in Position
(Generic Fireplace Shown)
Figure 6.3 Gasket in Place (Generic Fireplace Shown)
Note:
Vent attachment method varies by model.
Figure 6.4 Starting Collar
(Generic Fireplace Shown)
STARTING COLLAR
WARNING! Risk of Fire!
DO NOT remove the installed
piece of insulation from the firebox top on 8000CMOD-
IFT models. Overheating will occur.