Heat & Glo LifeStyle PCF-HNG Скачать руководство пользователя страница 14

14 

Heat-N-Glo Lifestyles • Patio Campfi re • 4004-001 Rev D • 07/05

A. Before Lighting Appliance

LP (Propane)

•  Before lighting this appliance, ensure both the LP tank 

valve and the manual shutoff valve are closed. Open the 
LP tank valve fi rst, THEN the manual shutoff valve. This is 
required due to built-in safety features of your LP tank. 

Natural Gas

•  Before lighting this appliance, ensure  the manual shutoff 

valve is open. 

Fire Risk
Burn Risk
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT

Glass and other surfaces are hot during 
operation and cool down.

WARNING

• Keep 

children 

away.

• 

CAREFULLY SUPERVISE children in same room as 
appliance.

•  Alert children and adults to hazards of high 

temperatures.

•  Keep clothing, furniture, draperies and other 

combustibles away.

Improper installation, adjustment, alteration, service or 
maintenance can cause injury or property damage. Refer 
to the owner’s information manual provided with this 
appliance. For assistance or additional information consult 
a qualifi ed installer, service agency or the gas supplier.

WARNING

Do NOT use this appliance if any part has been under 
water. Immediately call a qualifi ed service technician 
to inspect the appliance and to replace any part of the 
control system and any gas control which has been 
under water.

WARNING

Operating Instructions 

Before operating this appliance, have a qualifi ed 
technician:

•  Inspect the burner before each use of the gas log set. If 

there is any evidence that the burner is damaged, it must 
be replaced before operating. 

•  Review proper placement of logs.
•  Check the air shutter adjustment.
•  Ensure that there are no gas leaks.
•  Ensure that the fl ow of combustion and ventilation air is 

not obstructed.

Содержание PCF-HNG

Страница 1: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department Installation and service must be performed by a quali...

Страница 2: ...max 14 0 in w c 3 5 kPa Manifold Pressure Puissance de pression d admission de 3 5 in w c 87 kPa WARNING Must Not Be Used For Cooking AVERTISSEMENT Ne pas utiliser pour la cuisson WARNING For Outdoor...

Страница 3: ...s 7 C Framing Enclosure for LP Gas Supply System 8 4 Gas Information 9 A Fuel 9 B Gas Pressure 9 C Gas Connection 9 D High Altitude Installations 10 E LP Gas Supply 10 5 Finishing 11 6 Appliance Setup...

Страница 4: ...Set STANDARD IAS US requirements for Outdoor Gas Fireplaces Draft 4 96 and ANSI Z21 58 1995 CGA 1 6 M96 B BTU Speci cations C High Altitude Installations U L Listed gas appliances are tested and appro...

Страница 5: ...king Place the Patio Camp re on a at and stable surface in an outdoor location such as a patio or deck This location must be adjacent to the gas supply line or LP gas supply cylinder DO NOT locate the...

Страница 6: ...components from the packaging The gas logs may be packaged separately and must be eld installed Report to your dealer any parts damaged in shipment Read all of the instructions before starting the ins...

Страница 7: ...k Provide adequate clearance Around air openings For service access Locate appliance away from traf c areas WARNING A Select Appliance Location When selecting a location for your appliance it is impor...

Страница 8: ...area of 10 square inches 64 5 sq cm If ventilation openings at oor level are in a side wall there must be a least two openings The bottom of the openings must be at oor level and the upper edge can t...

Страница 9: ...ine should be piped to the 1 2 in connection on the manual shutoff valve Fire Risk Explosion Risk Verify inlet pressures High pressure may cause overfire condition Low pressure may cause explosion Ver...

Страница 10: ...ies E LP Gas Supply The pressure regulator and hose assembly supplied with LP models must be used Replacement pressure regulators and hose assemblies must be those speci ed in this manual The LP gas s...

Страница 11: ...nishing A decorative surround can be made from noncombustible material such as bricks landscape blocks rocks etc or two models of fabricated surrounds are available see Fig ures 5 1 and 5 2 and Sectio...

Страница 12: ...valve marked USE WITH TYPE 1 Inspect the hose shipped with the appliance for any damage Do not use if there is evidence of damage Connect the end of the hose onto the ON OFF gas valve of the appliance...

Страница 13: ...in the log base over the locating button on the burner top see Figure 2 1 for locating button Position the logs by placing the corresponding letter number combinations located on the logs Figure 6 3 w...

Страница 14: ...ther combustibles away Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For a...

Страница 15: ...sult in a re or explosion D Do not use the appliance if any part has been under water Immediately call a quali ed service technician to inspect the appliance and to replace any part which has been und...

Страница 16: ...quently Asked Questions C After the Appliance is Lit Initial Break in Procedure When you light the appliance you may notice that it pro duces heat which may have an odor or smell If you feel this odor...

Страница 17: ...to be taken This troubleshooting guide can only be used by a quali ed service technician 8 Troubleshooting Symptom Possible Causes Corrective Actions 1 Decorative gas log set won t light A No LP in t...

Страница 18: ...s Screw tips that have penetrated the sheet metal are sharp and should be avoided 2 Remove any foreign objects 3 Inspect for paint condition warpage corrosion Sand and repaint as necessary 4 Check the...

Страница 19: ...Heat N Glo Lifestyles Patio Camp re 4004 001 Rev D 07 05 19 This page intentionally left blank...

Страница 20: ...ATIO CAMPFIRE Beginning Manufacturing Date N A Ending Manufacturing Date Active 1 2 4 3 5 7 6 Description of Part PCF HNG PCFL HNG Qty 1 Ring 35272 1 2 Burner Assembly 35323 1 3 Flex Tube 4021 233 1 4...

Страница 21: ...ts Diagram PCF HNG PCFL HNG Service Parts PATIO CAMPFIRE Beginning Manufacturing Date N A Ending Manufacturing Date Active Description of Part PCF HNG PCFL HNG Qty R Log Assembly 34382 1 Y Log Base 34...

Страница 22: ...Only Hearth Home Technologies approved accessories may be used safely WARNING Optional Accessories shipped separately PCF Cover Vinyl Cover for Patio Camp re ROCK RING Rock Ring Decorative MESA Mesa...

Страница 23: ...een removed repaired or replaced before Hearth Home Technologies has been afforded a reasonable opportunity to inspect the Product This warranty is limited to the replacement or repair of defective co...

Страница 24: ...ation Read understand and follow these instructions for safe installation and operation D O N O T D I S C A R D This product may be covered by one or more of the following patents United States 459351...

Отзывы: