Heat & Glo LifeStyle CF550E-B Скачать руководство пользователя страница 18

Heat & Glo • CRESTFIRE Series Electric Fireplace • 4030-781 Rev F • 10/06

18

Troubleshooting 

A. Troubleshooting Guide

Issues

Possible Causes

Solutions

Heater doesn’t turn on with the main 
switch or remote transmitter.

1. Power switch is off.

1. Turn the power switch to the “ON” position.

2. Circuit breaker is tripped

2. May need to put the heater on a dedicated service or 

reduce the number of appliances on the circuit.

3. Heater is unplugged from wall outlet.

3. Plug the cord into an outlet.

4. Loose wiring.

4. Check all wiring for loose connections.

Heater is on, but no 

fl

 ame or low 

fl

 ame 

intensity.

1. The bulbs are burned out

1. Replace the bulbs.

2. Loose wiring.

2. Check all wiring for loose connections.

Flames are frozen.

1. Loose wiring.

1. Check all wiring for loose connections.

2. Flame element is not attached to the 

motor.

2. Reattach the 

fl

 ame element to the motor.

3. Motor is defective.

3. Replace the motor.

Excessive noise in the lower portion of 
the heater.

1. Flame element isn’t seated properly.

1. Reinstall the 

fl

 ame element.

2. Motor is defective.

2. Replace the motor.

Heater/blower assembly doesn’t come 
on.

1. Heater/blower assembly switch is off.

1. Turn the heater switch to the “ON” position.

2. Thermostat is set too low.

2. Move the thermostat knob clockwise until you hear a 

“click”.

3. Heater/blower assembly is overheated.

3. The heater/blower assembly is protected by a thermal 

cutout switch. Shut off all heater switches on the dash-
board including the main power switch. Wait 5 minutes, 
then turn the heater on.

4. Loose wiring.

4. Check all wiring for loose connections.

Fan runs but not heat is put out.

1. Loose wiring.

1. Check all wiring for loose connections.

2. Bad heating element.

2. Replace the heater/blower assembly.

Heater element is on but fan doesn’t 
run.

1. Loose wiring.

1. Check all wiring for loose connections.

2. Fan is defective.

2. Replace the heater/blower assembly.

The heater/blower assembly doesn’t 
turn off.

1. Thermostat is set too high.

1. Move the thermostat knob counter-clockwise until you 

hear a “click”.

Excessive noise in upper portion of the 
heater.

1. Build up of dirt on the fans.

1. Clean all fans.

2. Heater fan is defective.

2. Replace the heater/blower assembly.

Remote control doesn’t work.

1. Remote is out of range.

1. Move remote closer to the heater.

2. Low batteries.

2. Replace the batteries.

Odor.

The heater may emit a slight, harmless 
odor when 

fi

 rst used. This is a normal 

condition caused by initial heating of the 
internal parts and will not occur again.

Содержание CF550E-B

Страница 1: ...BURNS MAY RESULT CLOTHING IGNITION MAY RESULT WARNING Keep children away CAREFULLY SUPERVISE children in same room as heater Alert children and adults to hazards of high temperatures Keep clothing fu...

Страница 2: ...tion contained in this owner s manual unless noted otherwise applies to all models Your new Heat Glo electric fireplace will give you years of durable use and trouble free enjoyment Welcome to the Hea...

Страница 3: ...0 5 Heater Preparation 11 A Secure and Level the Heater 11 6 Finishing 12 A Finishing Material 12 B Finishing Checklist 12 C Mantel 13 7 Heater Setup 14 A Remove Shipping Materials 14 B Clean Heater 1...

Страница 4: ...2 No 46 in Canada and has been listed by Underwriters Laboratories Inc for installation as described in this manual All compo nents are UL or CSA safety certified This heater has been tested and list...

Страница 5: ...onnect heater turn controls to OFF then remove plug from outlet Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage...

Страница 6: ...remove the heater and components from the packaging Report to your dealer any parts damaged in shipment Read all the instructions before starting the installation Follow these instructions carefully...

Страница 7: ...a bathtub or other water container Contact local building administrator for information on bathroom intallations DANGER Fire Risk Prevent contact with sagging loose insulation Do NOT install against...

Страница 8: ...heater must be adhered to A B header height 14 in 356 mm If using the PBT or BKT Cabinet Trim Kits increase the width A by 1 1 4 in 32 mm and header height B by 5 8 in 16 mm Mantel height listed is m...

Страница 9: ...he current rating of the circuit breaker Before plugging heater into wall outlet make sure all control switches are in the OFF position To access the controls lift up on the lower grille panel and rot...

Страница 10: ...and install the cable clamp not provided into the hole Feed 8 in of service wire through the cable clamp and secure Connect the black wire from the service to the L1 terminal Connect the red wire fro...

Страница 11: ...eater Installation other than as instructed by Hearth Home Technologies Inc is strictly prohibited Do not operate the heater without fully assembling all components Installation and or use of any comp...

Страница 12: ...ailing flanges Allow room for the front to be added and the heater to be anchored B Finishing Checklist Power supply service must be either completed or placed within the heater prior to finishing to...

Страница 13: ...Specifications Fire Risk Do NOT obstruct air inlet or outlet grilles Do NOT modify grilles Modifying or covering grilles could cause temperature rise and fire hazard Finishing materials must not inter...

Страница 14: ...the lower louver assembly from the pack and install as shown in Figure 7 4 B Clean Heater The heater was cleaned at the factory but dust may have accumulated during shipping Vacuum firebox area and wi...

Страница 15: ...anual switches remote control and wall switch will not work MOTION INTENSITY THERMOSTAT HEATER MAIN POWER LEARN MOTION INTENSITY THERMOSTAT HEATER BLOWER ASSEMBLY SWITCH MAIN POWER SWITCH LEARN Figure...

Страница 16: ...smitter s battery Initialization only has to be done once Turn the main power switch on Locate the LEARN button on the dashboard The LEARN button is located behind the lower grille panel To push the b...

Страница 17: ...ou would like to change the setting you will have to access the manual controls located on the heater to set the desired position The heater must be turned on and off by the wall switch D FCC Requirem...

Страница 18: ...ch is off 1 Turn the heater switch to the ON position 2 Thermostat is set too low 2 Move the thermostat knob clockwise until you hear a click 3 Heater blower assembly is overheated 3 The heater blower...

Страница 19: ...panel can be cleaned with a damp cloth using a mild soap and water solution DO NOT USE GLASS CLEANER IT WILL RUIN THE ACRYLIC PANEL The acrylic panel should be com pletely dried with a lint free clot...

Страница 20: ...e Figure 10 2 Pull the heater blower assembly out of heater Slide the heater blower assembly back into the heater making sure that the wires do not touch the heater blower assembly housing Once the fr...

Страница 21: ...429 mm 36 in 914 mm 14 in 356 mm 31 in 787 mm 30 in 762 mm 17 1 4 in 438 mm 31 1 8 in 791 mm 3 1 8 in 79 mm 6 1 2 in 165 mm CF550E B CF550EV B CF550ENH B 22 in 559 mm 41 in 1041 mm 14 in 356 mm 34 5...

Страница 22: ...12V BATTERY COMPARTMENT FRONT BACK SIGNAL LIGHT ON OFF BUTTONS RCE HNG B Remote Control DM1031 DM1036 DM1031B DM1036B DM1031S DM1036S Bi fold Glass Doors WSK 21 WSK 21 W Wall Switch Kit left right RF5...

Страница 23: ...6E CF750E B Series CF550E B CF550EV B CF550ENH B Item Description DF 550M Black Middle Door PB 550 Polished Brass Strips 5 BN 550 Brushed Nickel Strips 5 SRV550 175 PB Polished Brass Hood SRV550 175 B...

Страница 24: ...750E B Series Quick Tile Black and Brass Surrounds Surrounds no suffix Polished Brass Finish BK Black Finish Flush Surrounds chase installations only CF550E B Series CRF750E B Series ROF44SB_ ROF48DB_...

Страница 25: ...l not apply if in the sole judgement of the Company damage or failure has resulted from accident alteration misuse abuse incorrect installation or operation on an incorrect power source The foregoing...

Страница 26: ...N O T D I S C A R D This product may be covered by one or more of the following patents United States 4593510 4686807 4766876 4793322 4811534 5000162 5016609 5076254 5113843 5191877 5218953 5263471 5...

Отзывы: