background image

3

WARNING

Risk of electric shock

!

DO NOT OPEN!

No user-serviceable parts inside!

ALWAYS disconnect

this unit from the

power

supply

before

performing any

assembly

or

cleaning

, before

replacing the light bulb

, or before

relocating

the electric fireplace.

NEVER

use this heater in

bathrooms, laundry rooms

, or any other location where the

heater could fall into a

bathtub

or

pool

,

become damp

or

come in contact with water

.

NEVER

hang this unit on a wall

directly below an electrical outlet.

NEVER

operate this heater if the

power cord

or

plug

has become

damaged,

or if the

grounding pin

is

damaged

or

missing.

Place the heater near a wall outlet so an extension cord is not needed. If an extension cord is

needed, the

gauge

of the cord

must be at least 14AWG,

and the

rating must be at least

1875 Watts

.

NEVER

use a

smaller gauge

cord with a

lower rating

. Doing so may result in

fire

or

electric shock

.

Avoid hazards

due to resetting of the thermal cut-off switch.

NEVER

control this unit with a

timer

, or allow it to be on a

circuit regularly switched off by the utility

.

ONLY

use this heater on a

110~120 Volt 15 Amp grounded circuit

.

NEVER overload the

circuit.

If this heater trips the circuit breaker, unplug all other appliances on the same circuit

before the next use. Avoid plugging other appliances into the same circuit as this heater.

NEVER

plug this heater into an outlet that is

old

,

cracked

, or has any

loose wires or

connections

. Plugging this heater into a faulty outlet could result in

electric arcing

within

the outlet that could cause the

outlet

to

overheat or catch fire

.

ALWAYS

check your heater cord and plug connections with

each use

!

i)

MAKE SURE

the plug fits tight in the outlet! Faulty wall outlet connections or loose plugs

can cause the outlet to overheat.

ii)

Heaters draw more current

than small appliances.

Overheating

may occur even if it

has not occurred with the use of other appliances.

iii) During use

check frequently

to see if the

plug outlet or face plate

is

HOT

!

iv) If the outlet or face plate is

HOT

,

discontinue use immediately

and have a qualified

electrician inspect and/or replace the faulty outlets.

The cord supplied with the heater has a

plug with two blades (live and neutral) and

one round pin (ground). If a 3-slot

receptacle is not available, an adapter

MUST

be used. The adapter

MUST

be

properly grounded

to the outlet box (see

figure at right).

Содержание BEF-23BM03

Страница 1: ...ing all safety information before plugging in or using this product Failure to do so could result in fire electric shock or serious personal injury CAUTION Keep this owner s manual for future reference If you sell or give this product away make sure this manual accompanies this product ELECTRIC FIREPLACE HEATER MODEL BEF 23BM03 ...

Страница 2: ...ularly inspect all air vents to make sure they are free from dust lint or other blockage Unplug the unit and clean with a vacuum ONLY DO NOT rinse or get wet WARNING For residential use only NOT for commercial use NEVER use this fireplace for other than its intended purpose ALWAYS HANG UNIT BEFORE USE DO NOT turn on or use while the unit is sitting on the floor ground or other surface The wall mou...

Страница 3: ... a 110 120 Volt 15 Amp grounded circuit NEVER overload the circuit If this heater trips the circuit breaker unplug all other appliances on the same circuit before the next use Avoid plugging other appliances into the same circuit as this heater NEVER plug this heater into an outlet that is old cracked or has any loose wires or connections Plugging this heater into a faulty outlet could result in e...

Страница 4: ...ct Failure to do so could result in electric shock fire serious injury or death Power Plug the power cord into a 110 120 Volt 15 Amp grounded outlet see IMPORTANT SAFETY INFORMATION on Pages 2 and 3 Make sure the outlet is in good condition and that the plug is not loose NEVER exceed the maximum amperage for the circuit DO NOT plug other appliances into the same circuit Methods of Operation This e...

Страница 5: ...f TIMER TIMER button Controls timer settings to turn off fireplace at selected time Settings range from 1 hour to 8 hours 1 Press once LED Indicator light turns on Timer is set to 1 hour 2 Press again until desired setting is reached Indicator lights show setting FLAME FLAME Makes flame effect dimmer NOTE Flame effect stays on until power button is turned off Flame effect must be on for heater to ...

Страница 6: ...n until desired setting is reached Flame effect continues to get brighter each time button is pressed HEATER HEATER button Turns heater on and off NOTE The heater only works when the flame effect is on If the flame effect is off the heater will not turn on NOTE To prevent overheating the heater blows cool air for 30 seconds after it turns off 1 Press once LED Indicator lights up Continue press Fan...

Страница 7: ... sprays or any cleaner that could scratch the surface Vents Use a vacuum or duster to remove dust and dirt from the heater and vent areas Plastic Wipe gently with a slightly damp cloth and a mild solution of dish soap and warm water NEVER use abrasive cleansers liquid sprays or any cleaner that could scratch the surface Maintenance Risk of electric shock DO NOT OPEN any panels No user serviceable ...

Страница 8: ...ian to replace flame motor 3 Flame Rod out of place due to rough transit handling of the product This issue can be corrected as simple as removing the glass flipping the fireplace upside down removing a set of screws that are holding the bottom frame plate and placing the flame rod back into place 1 Disconnect from power source and inspect wiring for loose connections and repair or replace if nece...