![Heartland Appliances 3535 Скачать руководство пользователя страница 58](http://html.mh-extra.com/html/heartland-appliances/3535/3535_installation-and-operation-manual_2114856058.webp)
Air Shutter Adjustment - Metro & Legacy II
Serial Numbers HPF#####
IMPORTANT: ALL GAS WORK TO BE PERFORMED BY A QUALIFIED GAS TECHNICIAN.
Air Shutter Adjustments may be needed in the field after conversion or new appliance installation.
Step 1: remove backguard held by 3
screws and washers.
Step 2: Remove burner rings,
grates, etc. from top.
Step 3: Push up on stove top. A
sturdy tap may be needed to
dislodge pems holding top to stove
Step 4: Using support bar, swing up
and attach to manifold.
PUSH UP
Step 3: Remove 4 screws securing
metal partition for burner access.
Step 4: Air shutter adjustment for
simmers: intake hole covered 1/4 for
LP & 1/2 for Nat Gas. Simply move
metal sleeve to open or close the air
shutter as needed.
Step 5: Air Shutter Adjustment for
main burners: air gap between jet
and sleeve is 1/2” L/P; 1/4” Nat Gas
Step 6: Grill models only. Air
shutter adjustment: LP fully open,
Nat Gas open 0.40”.
Step 7: Burner cap assembly: caps
must “lock” in place to ensure a flat
surface is provided and flames are
evenly distributed out of cap ports.
example of improper assembly.
Note: Improper assembly causes
erratic flames & continuous spark-
ing (could lead to component failure
Ports
Important: tab must
be locked in position
on the burner base
correct
incorrect