All  termination  caps  must  be  no  less  than  18” 
(457mm)  horizontally  from  any  roof  or  vertical 
surface. See Figure 9. 

  The  termination  must  fall  within  the  chart  in 

Figure 13. 

  The maximum vertical 

run is 35’  

The vent/air intake termination clearances above

 

the 

high side of an angled roof are as follows:

 

  

Roof Pitch 

Feet 

Meters 

Flat to 6/12

 

1

 

0.3

 

7/12 to 9/12

 

2

 

0.6

 

10/12 to 12/12

 

4

 

1.2

 

13/12 to 16/12

 

6

 

1.8

 

17/12 to 21/12

 

8

 

2.4

 

 
 
 
 

 

Figure 9 - Termination Cap clearances 

 
 

P

REFABRICATED 

&

 

F

IREPLACE 

C

HIMNEY 

I

NSTALLATIONS

 

 

The Stowe 8324 is approved for use with direct vent 
chimney conversion kits in masonry or prefabricated 
solid  fuel  listed  chimneys.  The  following  installation 
requirements must be followed: 

 

  The termination must fall within the chart shown 

in Figure 12.  

  In  a  masonry  chimney,  a  fireclay  liner  or  listed 

steel  liner,  must  be  present  the  entire  length  of 
the chimney. 

 

The maximum length of vent is 35’. 

  The  liner  must  have  an  inside  dimension  or 

diameter 6” or greater. 

  Prefabricated  chimneys  must  be  UL103  or  ULC 

S-629  listed  and  have  a  minimum  INSIDE 
diameter of 6”. Prefabricated chimneys must be 
listed  for  the  sp

ecific manufacturer’s conversion 

kit.  

 

The  use  of  an  existing  chimney  as  an  air  intake  is 
not  listed  under  the  ANSI  Z21.88-1999-CSA  2.33-
M99  test  methods;  this  installation  has  been  tested 
and  approved  by  Intertek  Testing  Services  with  an 
appropriate  test.    The  code  authority  having 
jurisdiction  must  be  consulted  prior  to  proceeding 
with this installation method. 
 

H

ORIZONTAL 

T

ERMINATION

 

  The  termination  must  fall  within  the  area  shown 

in Figures 9 & 12. 

  A  minimum  of  9"  rise  is  required  either  directly 

off the heater or with the use of a minimum of a 
14” snorkel. 

  Use  a  vinyl  siding  Stand-Off  when  installing 

against  vinyl  siding.  The  termination  cap  must 
not be recessed into the wall or siding. Do not fill 
air spaces with any type of insulation material.  

  A  mi

nimum  10”X10”  square  hole  is  necessary 

for  proper  pipe  clearance  through  a  wall, 
provided  the  vent  is  positioned  to  maintain  2” 
minimum  clearance  at  the  top.  A  1”  minimum 
clearance must be maintained to combustible  
materials around the other sides.  

  All horizontal terminations must also comply with 

the 

clearance 

specifications 

to 

adjacent 

structures outlined in Figures 9 & 12.  

  Horizontal sections require a 1/4" rise every  12" 

of horizontal run. 

 

NOTE: For each 90

 0

 elbow after 2, remove 5' from 

the allowable horizontal run. For Canadian 
installations: remove 4' from the allowable 
horizontal run. 

  At  minimum  vertical  rise,  maximum  horizontal 

run is 1

0’. (If a 14” snorkel termination is used a 

maximum  horizontal  run  of  10

’  is  also 

applicable.)  

 

WARNING:  FAILURE  TO  USE  ONLY  PARTS 
SPECIFICALLY  APPROVED  FOR  USE  WITH  THIS 
APPLIANCE 

MAY 

RESULT 

IN 

PROPERTY 

DAMAGE OR PERSONAL INJURY.

 

 

Содержание Stowe 8324

Страница 1: ...t perform installation and service of this appliance In the Commonwealth of Massachusetts all installation of gas lines and gas fittings must be performed by a licensed gas fitter or licensed plumber...

Страница 2: ...Page 1 of 33 Intentionally Blank...

Страница 3: ...pt in a safe place as proof of purchase Serial Number Fuel type Natural Gas Liquid Propane Sold by Date of Purchase Address Phone E mail Website Installed by Date of Installation Address Phone E mail...

Страница 4: ...loor Protection 9 Venting Information 10 Venting Connection 10 Approved Systems 11 Minimum Venting 12 Electrical System Information 16 Gas Supply Connections 17 Gas Connections 18 Initial Leak Check 1...

Страница 5: ...s 02202 Manufactured and Warranted by Hearthstone Quality Home Heating Products Inc 317 Stafford Ave Morrisville VT 05661 8695 USA www hearthstonestoves com Figure 1 Stowe DV Dimensions Specification...

Страница 6: ...nit will remain appealing while providing years of quality performance The installation must conform to local codes or in the absences of local codes the current National Fuel Gas Code ANSI Z223 1 NFP...

Страница 7: ...E COMPARTIMENT DES COMMANDES SONT PROPRES VOIR LES INSTRUCTIONS D INSTALLATION ET D UTILISATION QUI ACCOMPAGNENT L APPAREIL Hot Surfaces Certain exposed surfaces of the Stowe will reach high temperatu...

Страница 8: ...INSTALLATION PREPARATION CODES Adhere to all local codes or in their absence the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223 1 NFPA 54 or CAN CGA B149 Installer l appareil selon les codes o...

Страница 9: ...still occur during transit Take care to inspect for damage when unpacking and installing the unit DO NOT INSTALL OR PUT INTO SERVICE A DAMAGED OR INCOMPLETE HEATER Remove the shrink wrap and other pa...

Страница 10: ...adequate ventilation Minimum clearances to combustibles must be maintained as shown in Figures 5 8 Note The rear clearance to combustibles is determined by either the unit s or the vent pipe s minimum...

Страница 11: ...tone Quality Home Heating Products Inc STOWE Model 8324 10 Figure 5 Minimum Wall Clearances Figure 6 Corner Clearances Figure 7 Horizontal Vent Mantle Clearance Figure 8 Snorkel Termination Mantle Cle...

Страница 12: ...RNING IN HIGH WIND AREAS AND PARTICULARLY COLD CLIMATES IT MAY BE NECESSARY TO HEAT YOUR VENT SYSTEM WITH THE PILOT PRIOR TO IGNITION OF THE MAIN BURNER IN THESE INSTANCES IT IS RECOMMENDED THAT YOU L...

Страница 13: ...88 1999 CSA 2 33 M99 test methods this installation has been tested and approved by Intertek Testing Services with an appropriate test The code authority having jurisdiction must be consulted prior to...

Страница 14: ...e wall Ensure both of the retaining straps extend through interior wall thimble Before attaching the vent termination to the outside of the house run a bead of non hardening mastic around its outside...

Страница 15: ...CAN We strongly recommend 12 inches particularly where strong winds prevail H Not to be installed within 15 feet 4 5m above a meter regulator assembly within 3 feet 91cm horizontally from the center l...

Страница 16: ...Hearthstone Quality Home Heating Products Inc STOWE Model 8324 15 Figure 13 Venting Termination Diagram...

Страница 17: ...ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING ATTENTION AU MOMENT DE L ENTRETIEN DES COMMANDES TIQUETEZ TOUS LES FILS AVANT LE D BRANCHEMENT DES ERREURS DE...

Страница 18: ...es equal to or greater than psig Over pressurizing can damage the control resulting in leakage or control malfunction NOTICE A QUALIFIED TECHNICIAN MUST CONNECT THE HEATER TO THE GAS SUPPLY AND LEAK T...

Страница 19: ...a fire or explosion GAS CONNECTIONS Connection Main Gas Tubing connections 1 Do NOT use pipe joint compound or Teflon PTFE tape 2 Slip nut and ferrule over tubing 3 Slide nut and ferrule into place a...

Страница 20: ...gs will last a long time however they will break if subjected to rough or improper handling Exact positioning of the log set is required in order to obtain a pleasing flame pattern and efficient combu...

Страница 21: ...n 7 Place small tufts of the Platinum Bright Embers on the burner and log surfaces for additional glow as desired do not block burner ports Figure 24 Platinum Bright Embers Enlarged to Show Detail REM...

Страница 22: ...l valve Before lighting smell or use a gas detector all around the appliance area to check for gas leaks Be sure to test near the floor because some gases LPG are heavier than air and will settle on t...

Страница 23: ...erly adjusted and installed thermostat By adjusting the variable output control located on the gas control valve the rate of heat output is varied to meet the heating requirements of the season Choosi...

Страница 24: ...aft if necessary Controlling the draft also changes the aesthetics of the flame The restrictor plate has a large range of unlimited settings see Figures 29 30 The adjustment point is on the left side...

Страница 25: ...dic cleaning to prevent the accumulation of dust lint and other debris To clean the firebox set the switch to the OFF position and turn off the gas supply to the valve When the unit is cool remove the...

Страница 26: ...rom the glass by grasping one end and pulling firmly Clean off as much of the hanging fiber hairs as possible 2 Locate the 3 4 x 1 16 flat tape gasket Peel the adhesive protecting paper away from one...

Страница 27: ...0 VALVE SIT UNIVERSAL 3160 107 GASKET REAR ORIFICE PLATE 7211 370 PILOT TOP CONV 3 WAY 3160 150 GASKET HEAT EXCHANGER 4 x14 5 7211 588 BURNER 3160 152 GASKET PILOT 1 75 x3 ADHESIVE BACK 3160 155 GASKE...

Страница 28: ...er sitting for off season summer pilot assembly may be dirty E Clean or replace the pilot assembly 2 Pilot will not stay lit after carefully following lighting instructions A Low or too high gas press...

Страница 29: ...bly If the meter reading is OK but the burner does not come on replace the gas valve C Plugged burner orifice C Remove and check burner orifice clean or replace Note do not use any metal cleaning devi...

Страница 30: ...lear obstructions B3 Clear obstructions C If gas pressures are correct and the flames stay the same adjust the air shutter for a proper burn 9 Burner flashback Air gas mixture ignites inside the burne...

Страница 31: ...Hearthstone Quality Home Heating Products Inc STOWE Model 8324 30 07044 2 RATING LABEL...

Страница 32: ...ot listed elsewhere Any parts repaired or replaced during the limited warranty period will be warranted under the terms of the limited warranty for a period not to exceed the remaining term of the ori...

Страница 33: ...Such parts that are subject to normal wear and tear during the warranty period such as paint gaskets baffles refractory materials ash grates and glass 4 Damage resulting from installation modificatio...

Страница 34: ...rts for repair the return of the appliance for repair or to schedule a Dealer service call The Original Purchaser should refer to the Dealer Network search engine contained on Hearthstone s Web site w...

Отзывы: