minimum of 24 gauge sheet metal or a minimum of 4”
(102 mm) of masonry, both with a 1” (25mm) air space
between the wall and the masonry or sheet metal. Refer
to NFPA 211 for a complete list of non-combustible wall
configurations.
Using Single Wall Stove Pipe without Heat Shield
Residential and Mobile Home Installations for USA/Canada –
Rear Exit
Maintain 18” min. clearance between horizontal chimney connector and ceiling.
Parallel Installation:
A: Side walls to stove: 20” (51 cm)
B: Back wall to stove: 25” (64 cm)
Using Close Clearance Connector Pipe with Heat Shield
Residential and Mobile Home Installations for USA/Canada – Rear Exit
Parallel Installation:
A: Side walls to stove: 16” (41 cm)
B: Back wall to stove: 13” (33 cm)
Alcove Installation Using Close Clearance Connector Pipe and Rear Heat Shield
Residential and Mobile Home Installations for USA/Canada
A: Side walls to stove: 16” (41 cm)
B: Back wall to stove: 13” (33 cm)
C: Back wall to pipe: 6” (15 cm)
D: Top of stove to ceiling: 40” (102 cm)
The minimum alcove size:
Height: 68” (173 cm)
Width: 60” (152 cm)
Max. Depth: 48” (122 cm)
Alcove Installation Using Close Clearance Connector Pipe and Rear Heat Shield with NFPA 211
Protection.
Residential and Mobile Home Installations for USA/Canada
A: Side walls to stove: 8” (20 cm)
B: Back wall to stove: 9” (23 cm)
C: Back wall to pipe: 5” (13 cm)
D: Top of stove to ceiling: 36” (91 cm)
The minimum alcove size:
Height: 64” (163 cm)
Width: 40” (102 cm)
Max. Depth: 48” (122 cm)