Hearthstone Quality Home Heating Products, Inc.
®
Homestead Models #8570F and #8570H
26
Clearances from a Stove to a Corner
This table and illustrations list the minimum clearances from the back of your stove to the walls in a corner, both
when your stove is parallel and angled to the corner, and to unprotected and NFPA 211 protected walls.
Unprotected Surfaces
Protected Surfaces (NFPA 211)
Installation Type
Parallel Side
Parallel Rear
Corner
Parallel Side
Parallel Rear
Corner
No Heat Shield
(optional accessory)
23” (584-
mm)
26” (660-
mm)
18” (460-
mm)
12” (305-
mm)
12” (305-
mm)
12” (305-mm)
Rear Heat Shield, and
single wall connector
16” (406-
mm)
13” (330-
mm)
12” (305-
mm)
12” (305-
mm)
12” (305-
mm)
9” (229-mm)
Rear Heat Shield, and
double wall connector
16” (406-
mm)
7” (178-mm)
12” (305-
mm)
10” (254-
mm)
7” (178-mm)
7” (178-mm)
Clearances to an Alcove
This table and illustration list the minimum clearances from your stove to the walls of an alcove, both
unprotected and NFPA 211 protected walls.
Unprotected Surfaces
Protected Surfaces (NFPA 211)
Minimum Width
Maximum Depth
Minimum Height
(stove to ceiling)
Minimum Width
Maximum Depth
Minimum Height
(stove to ceiling)
59”
(1499-mm) 48”
(1220-mm) 36”
(915-mm) 51”
(1295-mm) 48”
1220-mm) 18”
(460-mm)