HearthStone Heritage 8022 Скачать руководство пользователя страница 8

Installation

U

NPACKING

 

Hearthstone Stoves packages your Heritage stove 
with the greatest care, so that it ships safely.  Under 
certain circumstances, however, damage can occur 
during transit and handling.  When you receive your 
stove, unpack it carefully, inspecting your stove and 
all parts for damage.  Also, make sure that all parts 
are included.  If any parts are damaged or missing, 
please contact your dealer immediately.  

Read this chapter to obtain a sound understanding 
of how to properly install your stove. 

I

NSTALLING 

Y

OUR 

S

TOVE

 

First, you must decide where your stove will reside.  
After choosing an appropriate spot, inspect this 
location to make sure that the stove will have 
enough clearance to combustible materials that 
would surround the stove.  These combustibles can 
include walls, floor, ceiling, fireplace, and chimney.  
You must carefully consider the clearances to all of 
these combustibles before actually connecting your 
stove.  When considering these clearances, also 
decide the kind of floor the stove will rest on.  The 
Heritage  8022  must be installed on a non-
combustible surface, use floor protection if 
necessary.   

Use this chapter  to plan how to install  your  stove in 
your particular location.  Consider both the 
clearances of the stovepipe and the stove itself to 
the surrounding combustibles.  Also consider access 
to the side door. 

If you use a close clearance connector pipe, it must 
be tested to UL standards and listed. Check the 
listing of your  pipe for actual clearances.  The 
diagrams in this manual represent typical 
installations, but are specific to the Simpson Dura-
Vent DVL brand.  Clearances cannot be reduced 
without the use of close clearance connector pipe 
and/or by protecting the surfaces per NFPA 211 
standards. 

Locate the stove centrally in your living area to allow 
the heat to travel naturally to distant rooms. It is not 
recommended that you locate your stove in an un-
insulated basement. The amount of radiant energy 
required to heat concrete basement walls is so great 
that most of the usable heat is absorbed by them 
and lost. 

Clearances to NFPA 211 Protected 
Surfaces 

You can reduce the clearances to combustible 
surfaces by using any National Fire Protection 
Agency (NFPA) approved wall protection system.  
Please refer to NFPA 211 for specifications and 
complete  details.  You can obtain this information 
directly from NFPA. 

 

 

National Fire Protection Agency 

 

Batterymarch Park 

 

Quincy, MA  02269 

 

1-800-344-3555 or 1-617-770-3000 

 

www.nfpa.org 

H

EARTH 

R

EQUIREMENTS 

A

ND 

F

LOOR 

P

ROTECTION

 

Combustible flooring must be protected with a 
covering of noncombustible material (slate, marble 
tiles, or other noncombustible material can be used 
for this purpose).  The floor protection must extend 
beyond 

the body

  of the stove at the minimum as 

follows: 

 

LEFT SIDE 16” (41 cm)* 

 

RIGHT SIDE 5” (13 cm) 

 

REAR 2” (5 cm)** 

 

FRONT 16” (41 cm)* 

 

*   Installations in Canada require 18” (46 cm) of floor protection 
on the left side and front. 
** Rear clearance required only if stovepipe runs horizontally back 
from the top or rear of the stove. 
 

 

Figure 4 – Hearth Pad Dimensions 

Note:

  Dimensions shown in figure above are measured from the 

body

 of the stove, not the legs. 

Minimum hearth pad dimensions can be reduced by 
installing the Side Door Lock Kit (Kit  90-70210). 

Hearthstone Quality Home Heating Products, Inc. 

®                                                                                                                                                                     Heritage Model 8022 

 

  Page 8 of 30 

Содержание Heritage 8022

Страница 1: ...e risk of fire follow the installation instructions Failure to follow these instructions may result in property damage bodily injury or even death SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CONTACT...

Страница 2: ...Intentionally Blank Hearthstone Quality Home Heating Products Inc Heritage Model 8022 Page 2 of 30...

Страница 3: ...SYSTEM 12 INSTALLING A VENTING SYSTEM 12 CONNECTING YOUR WOOD STOVE 13 INSTALLING IN A MOBILE HOME 17 OPERATION 18 CONTROLS AND FEATURES 18 CHOOSING FIREWOOD 19 WOOD HEAT VALUE 19 BUILDING A FIRE 20...

Страница 4: ...n death Locate your stove in a safe convenient open area away from traffic flow doors and hallways and near a chimney and chimney connector Review the proper clearance measurements from combustible su...

Страница 5: ...himney connector and chimney as recommended Follow these safety precautions Never modify this stove in any way especially the primary air control system Never burn kiln dried wood painted or treated w...

Страница 6: ...is new technology will not corrode rust dissolve or lose its strength however it is vulnerable to puncture or cracking due to rough handling PLEASE EXERCISE CARE WHEN LOADING WOOD OR CLEANING YOUR STO...

Страница 7: ...wide x 11 high 46 x 28 cm Side Door Size 10 5 wide x 8 5 high 31 8 x 21 6 cm Stovepipe Size 6 152 mm diameter Metal Chimney 6 152 mm inside diameter Masonry Chimney 6 15 2cm inside diameter round flu...

Страница 8: ...fic to the Simpson Dura Vent DVL brand Clearances cannot be reduced without the use of close clearance connector pipe and or by protecting the surfaces per NFPA 211 standards Locate the stove centrall...

Страница 9: ...rticularly air tight house The outside air kit for this stove allows for the direct connection of the stove s air intake to a minimum 3 76 mm diameter duct supplied by others which leads to the outsid...

Страница 10: ...es inches Unprotected Surfaces Protected Surfaces NFPA 211 Minimum alcove width 61 49 Maximum alcove depth 48 48 Alcove ceiling above stove top 57 24 If you use a rear heat shield to obtain reduced cl...

Страница 11: ...Figure 9 Mantle Clearances Side View Figure 8 Mantle Clearances Front View Hearthstone Quality Home Heating Products Inc Heritage Model 8022 Page 11 of 30...

Страница 12: ...bustibles discussed earlier to install your stove safely To protect against the possibility of a house fire you must properly install and constantly maintain the venting system Upon inspection immedia...

Страница 13: ...6 152 mm inside diameter flue for new installations A 6 diameter flue provides adequate draft and performance You can use an 8 203 mm diameter existing flue with a reducer An oversized flue contribute...

Страница 14: ...d chimney liner system meeting type HT requirements or other approved material Interior chimney requirements At least 2 51 mm clearance to combustible structure Fire stops must be installed at the spa...

Страница 15: ...rom combustibles by a minimum of 6in of glass fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge in thickness D Solid insulated listed factory...

Страница 16: ...Figure 11 Typical Venting Configurations Hearthstone Quality Home Heating Products Inc Heritage Model 8022 Page 16 of 30...

Страница 17: ...96N 7DP MH 7 Diameter S N 9196N 8DP MH 8 Diameter S N 9296N Each kit includes Stainless spark arrester cap storm collar Adjustable vented flashing 0 12 6 12 Two 24 Dura Plus chimney pipes 24 support b...

Страница 18: ...andle is located on the front lower left of the stove just under the ash lip The primary air control allows you to regulate the amount of air entering the firebox Generally the more air allowed into t...

Страница 19: ...igh Beech European 3 757 24 Maple Sugar 3 757 24 Oak Red 3 757 24 Ash White 3 689 23 6 Birch Yellow 3 689 23 6 Medium Juniper Rocky Mtn 3 150 21 8 Elm Red 3 112 21 6 Coffeetree Kentucky 3 112 21 6 Hac...

Страница 20: ...odors by opening a few windows or otherwise creating additional ventilation around your stove If any odor persists contact your dealer or an authorized service technician If you adhere to the followi...

Страница 21: ...m the glass in front in order for the air wash system to work properly Keep the front door and ash door closed while the stove is in use 6 Once the fire is burning well use the primary air control to...

Страница 22: ...sposing of ashes Ashes may be removed from the firebox with an ash shovel and placed into a suitable container The optional ash pan and ash pan access door are located under the ash lip The ash pan co...

Страница 23: ...heck the chimney at the top where it is coolest as well as from the bottom near the stove Accumulated creosote should be removed with a cleaning brush specifically designed for the type of chimney in...

Страница 24: ...et Apply the new gasket to the doorframe as illustrated 6 Place the gasketed glass onto the door Place a new clips and gasket squares around the glass and over the screw holes in the clip 7 Screw the...

Страница 25: ...s been used Such changes are normal and do not affect the operation or the integrity of the stove and do not require replacement If you observe a completely broken stone contact your dealer for servic...

Страница 26: ...our home is super insulated or especially well sealed the infiltration air supply to the interior of the house may be inadequate This phenomenon of air starvation within the building can be exacerbate...

Страница 27: ...ash grate Close the door tightly or replace the gaskets Slide ash grate to closed position Excessive Draft Check the installation Operate at LOW BURN Install stovepipe damper Deteriorated Cement Seal...

Страница 28: ...CONTROL HER1 TRI 2010 282 PLATE FLUE HER 1 MCR CAS MISC 2010 285 COLLAR FLUE MATTE HER 1 TRI MCR CAS 6400 40490 OWNER S MANUAL 2010 287 PLENUM SEC AIR BOT HER2 90 58210 COMPLETE GASKET KIT 2010 289 P...

Страница 29: ...Safety Rating Label Hearthstone Quality Home Heating Products Inc Heritage Model 8022 Page 29 of 30...

Страница 30: ...urces warranty registration Hearthstone Quality Home Heating Products Inc Warranty Department 317 Stafford Avenue Morrisville VT 05661 NOTE COMPLETING THE WARRANTY REGISTRATION FORM IS NOT REQUIRED AS...

Отзывы: