background image

HearthStone Quality Home Heating Products Inc 

®

 

                                                                                     

 Model  8220

          

14

 
Install the stove as close as practical to the 
chimney, while maintaining all proper 
clearances.  Install stovepipe that is as short and 
as straight as possible.  Horizontal runs

 of 

stovepipe should always rise away from the 
stove a minimum of 1/4" per foot (21mm/m). 
 

Long runs of stovepipe to increase heat 
dispersal are not recommended

.  Using longer 

lengths of stovepipe or more connecting elbows 
than necessary increase the chances of draft 
resistance and the accumulation of creosote 
buildup. 
 
In general, you do not need to install a stovepipe 
damper with the Deva.  Some installations, 
however, could benefit from a stovepipe 
damper, such as a tall chimney which can create 
a higher than normal draft.  In such cases, a 
damper can help regulate the draft.  The Deva 
requires a draft between 0.06" w.c. and 0.1" w.c.  
For drafts above 0.1" w.c, install a stovepipe 
damper. Locate your local HearthStone dealer to 
purchase a draft gauge to measure the draft of 
your chimney and flue system.  
 
Remember, the NFPA has recommended, 
minimum clearances for chimney connectors to 
combustibles such as walls and ceilings.  

 

 

C

ONNECTING 

Y

OUR 

W

OOD

-F

IRED 

C

OOKSTOVE 

 

 

You can install your Deva 100 to a prefabricated 
metal chimney or a masonry chimney. 

 

C

ONNECTING TO A 

P

REFABRICATED 

M

ETAL 

C

HIMNEY

 

 

When connecting the Deva 100 to a 
prefabricated metal chimney, you must follow, 
precisely, the manufacturer's installation 

instructions.  Use only Type HT (2100 deg. F), 
prefabricated metal chimneys listed per UL 103 
or ULC S629 standards. 

 
 

 

WARNING: 

DO NOT CONNECT THE STOVE TO A 
CHIMNEY FLUE SERVING ANOTHER 
APPLIANCE. 

 

Make sure the size of the chimney’s flue is 
appropriate for the Deva 100.  The Deva 100 
requires a 6" (152 mm) inside diameter flue for 
new installations.  A 6” diameter flue provides 
adequate draft and performance.  You can use 
an 8" (203 mm) diameter existing flue with a 
reducer.  An oversized flue contributes to 
creosote accumulation.  (In this case, bigger is 
NOT better.) 

 

When purchasing a prefabricated chimney to 
install with your stove, be sure to also purchase 
from the same manufacturer, the wall pass-
through (or ceiling support package), "T" 
section package, fire-stops (when needed), 
insulation shield, roof flashing, chimney cap, 
and any other needed accessories.  Follow the 
manufacturer’s instructions when installing the 
chimney and accessories.  In addition, be sure to 
maintain all manufacturers’ recommendations 
for the proper clearances to the chimney. 
 
There are two ways to install a prefabricated 
metal chimney: 
 

 

An 

interior

 installation where the chimney 

passes inside the residence through the 
ceiling and roof.

 

 

 

An e

xterior

 installation where the chimney 

passes through the wall behind the stove 
then up the outside of the residence.

  

 

Содержание Deva 100

Страница 1: ...isk of fire follow the installation instructions Failure to follow these instructions may result in property damage bodily injury or even death SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE Deva 100 Model 8220 6400 40460 Revised 10 12 07 CONTACT LOCAL AUTHORITIES HAVING JURISDICTION BUILDING DEPARTMENT or FIRE OFFICIALS ABOUT PERMITS REQUIRED RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA ...

Страница 2: ...HearthStone Quality Home Heating Products Inc 2 Model 8220 ...

Страница 3: ...0 Components of a Venting System 12 Installing a Venting System 13 CONNECTING YOUR WOOD FIRED COOKSTOVE 14 Connecting to a Prefabricated Metal Chimney 14 OPERATING YOUR DEVA 100 WOOD STOVE 19 CONTROLS AND FEATURES 19 CHOOSING FIREWOOD 20 BUILDING A FIRE 21 Building A Fire For Everyday Use 21 Burn Rate 22 Over Fire Caution 22 Removal And Disposal Of Ashes 22 MAINTENANCE 23 Creosote Formation And Ne...

Страница 4: ...e these instructions as well as national state and local building codes to install your cookstove Be sure to maintain the designated stovepipe and cookstove clearances to walls ceilings hearth and other combustible surfaces This will help reduce the risk of fire Failure to follow these instructions can result in property damage bodily injury and even death Locate your cookstove in a safe convenien...

Страница 5: ...ORMATION Read and understand this Owner s Manual thoroughly before installing and using this stove Make sure to install your stove According to the manufacturer s recommendations In accordance with all applicable codes With the proper sized chimney When using your stove Warn children and others unfamiliar with wood fired cookstoves the danger of touching hot radiating surfaces of your stove For yo...

Страница 6: ...urn drip into the firebox will may create an ignition Other safety guidelines Keep all combustible items such as furniture drapes clothing and other items at least 36 0 92 m from the cookstove See page 100 for more clearance to combustible information Install a smoke detector Keep a fire extinguisher handy We recommend the type rated A B C Dispose of ashes properly See page 22 PERIODIC CHECKLIST P...

Страница 7: ...ney fire follow these instructions 1 If the fire is too threatening leave the area and call the fire department immediately If not perform the next three steps 2 Close the primary air control 3 Close the stovepipe damper if present 4 Keep all doors to the stove closed WARNING DO NOT ATTEMPT TO PUT OUT A STOVEPIPE OR CHIMNEY FIRE BY THROWING WATER ONTO THE STOVE STOVEPIPE OR CHIMNEY THE EXTREMELY H...

Страница 8: ...eat Output 46 000 BTUs per hour of cordwood based on independent laboratory test results Maximum Log Length 17 43 cm fuel loading door Height 33 3 4 85 cm Width 40 102 cm Depth 23 3 4 60 cm Fuel loading door dimension 7 x 9 3 4 18 cm x 25 cm Stovepipe Size 6 15 2 cm diameter 2 1 2 23 3 4 33 3 4 40 23 1 4 26 3 4 7 6 33 1 2 6 3 4 6 17 3 4 6 Front ...

Страница 9: ...must carefully consider the clearances to all of these combustibles before actually connecting your cookstove When considering these clearances also decide the kind of floor the stove will rest on Depending on your floor you can install your stove as it is or use a floor protector some types of flooring may require additional floor protection Please use this section to plan how to locate your stov...

Страница 10: ...or s specification to an R value do one of the following If the R value is given use that value no conversion is needed If a K factor is given with a required thickness T in inches use this formula R value 1 K x T If a C factor is given use the formula R value 1 C To determine the R value of the proposed alternate floor protector Use either the K factor or the C factor formula explained above to c...

Страница 11: ... 63 160cm with single wall connector Minimum alcove width is 58 147cm with double wall connector Clearances Single wall connector Double walls connector Top Exit Rear Exit Top Exit Rear Exit in cm in cm in cm in cm A 10 26 4 11 4 11 4 11 B 10 26 4 11 4 11 4 11 C 16 41 16 41 14 36 16 41 D 21 5 55 n a n a 19 5 50 n a n a ALCOVE Top exit connector Clearances Single wall connector Double wall connecto...

Страница 12: ...necessary that if you install all of these components they must remain within the clearances to combustibles discussed earlier to install your stove safely To protect against the possibility of a house fire you must properly install and constantly maintain the venting system Upon inspection immediately replace rusted cracked or broken components The chimney connector is the stovepipe from the wood...

Страница 13: ...through or chimney support package also keeps the walls from igniting You must use one when connecting through a wall or ceiling to a prefabricated chimney Only install this stove to a lined masonry chimney or an approved high temperature prefabricated residential type building heating appliance chimney Do not connect this stove to a chimney serving another appliance you will compromise the safe o...

Страница 14: ...CONNECTING TO A PREFABRICATED METAL CHIMNEY When connecting the Deva 100 to a prefabricated metal chimney you must follow precisely the manufacturer s installation instructions Use only Type HT 2100 deg F prefabricated metal chimneys listed per UL 103 or ULC S629 standards WARNING DO NOT CONNECT THE STOVE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE Make sure the size of the chimney s flue is appro...

Страница 15: ...vepipe Shield Insulation Access door Masonry Chimney Chimney Sections Tee clean out Adjustable Roof Flashing Storm Collar Chimnet Cap Chimney is supported by Tee Support Bracket Chimney is supported by Ceiling Whenever possible choose an interior chimney An interior chimney heats up more quickly and retains its heat thus promotes a better draft and discourages the formation of creosote An exterior...

Страница 16: ...tove until the chimney is safe for use Make sure the chimney s cleanout is complete and working properly To avoid a loss of draft the cleanout must close off completely If allowed to cool your stove will perform poorly and creosote will build up in the chimney Make sure the size of the chimney s flue is appropriate for this stove and that it is not too large Use a masonry chimney with an 8 x 8 203...

Страница 17: ...eet 0 9 m higher than the highest part of the roof opening through which it passes At least 2 feet 0 6 m higher than any part of the roof within 10 feet 3 m measured horizontally from the top of the chimney This stove requires a minimum chimney height of 13 feet 4 m The maximum allowable chimney height is 30 feet 9 m ...

Страница 18: ...HearthStone Quality Home Heating Products Inc Model 8220 18 ...

Страница 19: ...g a fire in a cold Deva 100 you will need to use the flue bypass system This is the handle at the top center of your stove that pushes and pulls in and out To open the bypass pull the handle out This opens a bypass channel that allows the hot gases to heat up the chimney quicker This bypass allows for a direct outlet of the flue gases and smoke With the bypass closed the gases follow the normal ro...

Страница 20: ...OR ANY OTHER MATERIALS AS FUEL THEY ARE NOT SAFE DO NOT BURN GARBAGE The quality of your firewood affects heat output duration of burn and performance of your stove Softwoods generally burn hotter and faster while hardwoods burn longer and produce more coals Density and moisture content are two critical factors to consider when purchasing wood for your stove The following is a list of wood species...

Страница 21: ...to 431 mm long 2 Open the flue bypass system by pulling the handle out completely as described on page 18 3 Fully open the primary air control by pushing the lever toward the left of the stove 4 Light the paper under the kindling Leave the door slightly ajar momentarily until the kindling has started to burn and draft begins to pull 5 Close the door and allow the fire to burn 6 Once the kindling i...

Страница 22: ...al cordwood OPERATOR ERROR Make sure all the gaskets are in good condition Replace worn out or compressed gaskets Do not burn the stove with the fuel loading door or ash pan door in the open position Monitoring the temperature is the best way to determine that the stove is over firing If you suspect that your stove is over firing contact your dealer immediately Damage done by over firing is not co...

Страница 23: ...ccumulated it should be removed to reduce the risk of a chimney fire The venting system must be inspected at the stove connection and at the chimney top Cooler surfaces tend to build creosote deposits quicker so it is important to check the chimney at the top where it is coolest as well as from the bottom near the stove Accumulated creosote should be removed with a cleaning brush specifically desi...

Страница 24: ...If you replace the glass yourself wear work gloves and safety glasses The procedure for the fuel loading door glass and glass gasket replacement is as follows 1 Remove the top hinge straight up and away from the stove 2 Remove the door by pulling it up and away from the stove 2 Place the door face down on a flat smooth surface 3 Apply penetrating oil to the 2 screws in the retention frame Remove t...

Страница 25: ...ys promote a stronger draft Other draft guidelines are as follows AN AIRTIGHT HOUSE If your home is super insulated or especially well sealed the infiltration air supply to the interior of the house may be inadequate This phenomenon of air starvation within the building can be exacerbated if exhaust fans such as clothes dryers bathroom fans or cook stove exhaust fans are in operation within the ho...

Страница 26: ...LLED OR SHORT BURN Unsealed or Open Door Close the door tightly or replace the gaskets Excessive Draft Check the installation Operate at LOW BURN Install stovepipe damper Deteriorated Cement Seals Reseal the stove with furnace cement Extra Long Chimney Shorten the chimney Install stovepipe damper High Winds or Hilltop Location Install a chimney cap Excessive Draft Draft in excess of 0 1 wc should ...

Страница 27: ...S 91 59710 SIDE ASSEBLY 91 58710 TOP GLASS ASSEMBLY 91 58711 OVEN DOOR ASSEMBLY 91 58712 ASH DOOR ASSEMBLY 91 58713 FUEL LOADING DOOR ASSEMBLY HANDLES 2650 016 FLUE COLLAR 91 71710 OVEN DOOR HANDLE 5170 005 HANDLE BAR SUPPORT 91 71711 FIREBOX DOOR HANDLE 5170 007 HANDLE BAR 91 71712 ASH DOOR HANDLE 5170 010 REFRACTORY STONE BRACKET REFRACTORY STONE 3060 432 REFRACTORY BASE 3060 433 LEFT REFRACTORY...

Страница 28: ...TE AND INS TRUCTIONS INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY VENT REQUIREMENTS When installed on a combustible floor minimal hearth protection must be a non combustible material with an R value of at least 0 89 underneath the cookstove that extends 16 US 46cm CAN ear exit of the stove the floor protection must extend und...

Страница 29: ...anniversary of the Purchase Date Ceramic cook top LIMITED ONE YEAR WARRANTY HearthStone warrants the following parts of the wood burning cookstove against the following occurrences that result from defects in material and workmanship Enamel Finish against peeling or fading excluding chipping mechanical abrasion chemical abrasion or crazing Stove cement and all gaskets against breakage or deteriora...

Страница 30: ...TICULAR PURPOSE SHALL APPLY TO THE SUBJECT COOKSTOVE SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU THE WARRANTIES CONTAINED IN THIS DOCUMENT EXTEND ONLY TO THE ORIGINAL PURCHASER OF THE COOKSTOVE WARRANTED HEREUNDER THEY DO NOT EXTEND TO ANY SUBSEQUENT OWNERS UNDER NO CIRCUMSTANCES SHALL HEARTHSTONE BE LIABLE TO THE ORIGINAL...

Страница 31: ...r all shipping costs related to shipping Cookstove parts to and from HearthStone or a Dealer as the case may be Shipping cost for the Cookstove Within the first 1st year after the Purchase Date if the Original Purchaser is instructed to return the Cookstove to HearthStone or a Dealer for repair HearthStone will pay fifty percent 50 and the Original Purchaser will pay fifty percent 50 of the shippi...

Отзывы: