Hearthstone Quality Home Heating Products, Inc
®
Craftsbury (Model 8392)
10
C
OMBUSTIBLE
S
URFACE
R
EQUIRED
C
LEARANCES
Note: Dimensions shown in the following figures are from the furthest point on cast body of the stove unless otherwise
indicated.
It is very important to follow minimum clearances for chimney connectors to combustibles such as walls and
ceilings when installing the stove near combustible surfaces.
Figure 4
– Clearance to Combustibles
Parallel
Corner
Corner
Clearances
A
B
C
D
E
F
Single wall Connector
–
Inc. Rear Heat Shield
14
”-36cm 13-3/4”-35cm
18-3/4
”-
48cm
25-7/8
”-
66cm
7
”-18cm
17.25
”-44cm
Single Wall Connector
–
With Blower Kit Shield
14”-36cm 13-3/4”-35cm
18-3/4
”-
48cm
25-7/8
”-
66cm
7”-18cm
17.25”-44cm
Double Wall Connector
–
Inc. Rear Heat Shield
14”-36cm 9-3/4”-25cm
14-3/4
”-
38cm
25-7/8
”-
66cm
7”-18cm
17.25”-44cm
Double Wall Connector
–
With Blower Kit Shield
14”-36cm 9-3/4”-25cm
14-3/4
”-
38cm
25-7/8
”-
66cm
7”-18cm
17.25”-44cm
Single Wall Connector
–
No Rear Heat Shield
14”-36cm 16”-41cm
21”-54cm
25-7/8
”-
66cm
14
”-36cm
25-1/2
”-65cm
Alcove W/Sngl or Dbl Wall Conn
–
Inc. Rear Heat
Shield
14”-36cm 13-3/4”-35cm
18-3/4-
48cm
25-7/8
”-
66cm
See NFPA-211
Alcove W/Sngl or Dbl Wall Conn
–
With Blower Kit
Shield
14”-36cm 13-3/4”-35cm
18-3/4-
48cm
25-7/8
”-
66cm
See NFPA-211
Alcove Clearances (inches)
Unprotected Surfaces Protected Surfaces (NFPA-211)
Minimum alcove width
51-3/4
” – 132cm
See NFPA-211
Min. Alcove ceiling from floor with single wall connector
56” – 142.3cm
See NFPA-211
Min. Alcove ceiling from floor with double wall connector
56” – 142.3cm
See NFPA-211
FOR
BLOWER
KIT,
USE
KIT
#96-57400