HearthStone Champlain 8301 Скачать руководство пользователя страница 25

 

P

ARTS 

L

IST

 

 

 
PART # 

DESCRIPTION PART 

DESCRIPTION 

2310-020 BRICK

 

PANEL

 

FRONT 

5301-050 HEATSHIELD:

 

REAR,

 

RIGHT,

 

CHA/SAN 

23X0-440 FRONT

  

 5301-060 

RESTRICTOR

 

PLATE

 

ASSEMBLY 

23X0-845 TOP

 

GRILL 5301-070 

SHUTTLE

 

POSITION

 

INDICATOR 

2310-850 HEAT

 

EXCHANGER

 

BASE 5301-080 

OUTLET

 

RESTRICTOR

 

CLIP 

2310-860 HEAT

 

EXCHANGER 5701-925H 

STARTER

 

COLLAR 

2310-240 EXHAUST

 

BAFFLE 7200-349 

ORIFICE:

 

BURNER,

 

LP,

 

#49

 

SPUD 

3030-028 GLASS

 

 7211-390 

3-WAY

 

PILOT

 

HOOD

 

(W/

 

CLIP) 

3110-057 LOW

 

DENSITY

 

DOOR

 

ROPE

 

3/8" 7211-009 

PILOT

 

GAS

 

TUBE 

3160-075 HEAT

 

EXCHANGER

 

FLAT

 

ROPE

 

1/4” 7211-320 

VALVE

 

(NG) 

3160-080 GLASS

 

TAPE

 

3/4"

 

 7211-370 

PILOT

 

ASSEMBLY

 

(NG) 

3160-150 FIREBOX/AIR

 

HEAT

 

EXCHANGER

 

GASKET 7210-103 PIEZO

 

IGNITER 

3160-152 PILOT

 

GASKET 7211-017 

GAS

 

LINE

 

3/8

 

DIAMETER 

3160-157 GASKET

 

6"

 

 7211-221 

BURNER

 

ASSEMBLY 

3160-300 PRIMARY

 

AIR

 

CONTROL

 

GASKET 7211-430 

IGNITER

 

ELECTRODE 

3170-150 

PLATINUM BRIGHT EMBERS 

7211-470 THERMOCOUPLE 

5300-066 PIEZO

 

BRACKET 

7211-601 

BOTTOM RIGHT LOG 

5300-090 SECONDARY

 

AIR

 

PLENUM 

7211-602 REAR 

RIGHT 

LOG 

5300-112 RESTRICTOR

 

PLATE 

7211-603 

FRONT CENTER LOG 

5300-114 RESTRICTOR

 

PLATE

 

ROD 

7211-604 

BOTTOM LEFT LOG 

5301-010 FIREBOX:

 

CHA/SAN 

7211-605 

REAR TOP LOG 

5301-030 CONTROL:

 

PRIMARY

 

AIR

 

ASSEMBLY 7211-606 

FRONT 

TOP 

LOG 

5301-040 HEATSHIELD:

 

REAR,

 

LEFT,

 

CHA/SAN 

7211-517 EMBERS:

 

PYROTEK,

 

4

 

OZ. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accessories available

:

 

 

BLOWER

 

KIT

 

# (93-57010) 

REMOTE

 

CONTROL

 

ON/OFF

 

#

 

(90-56912) 

REMOTE

 

CONTROL

 

THERMOSTAT

 

#

 

(90-56914) 

 

 

WARNING!

 

DO NOT SUBSTITUTE MATERIALS.   

 

For replacement parts, or for information about parts or service, contact your authorized Hearthstone retailer. 
For the name of the authorized retailer nearest to you, visit our website at 

www.hearthstonestoves.com

 

24 

07044-2 

Содержание Champlain 8301

Страница 1: ...er service agency or gas supplier must perform installation and service of this appliance In the Commonwealth of Massachusetts all installation of gas lines and gas fittings must be performed by a lic...

Страница 2: ...Intentionally Blank Page 1 of 30...

Страница 3: ...pt in a safe place as proof of purchase Serial Number Fuel type Natural Gas Liquid Propane Sold by Date of Purchase Address Phone E mail Website Installed by Date of Installation Address Phone E mail...

Страница 4: ...ON 9 CLEARANCES TO COMBUSTIBLES 9 HEARTH REQUIREMENT FLOOR PROTECTION 9 VENTING INFORMATION 11 VENTING COMPONENTS CONFIGURATION 11 VENT CONNECTION 11 ACCEPTABLE DIRECT VENT TERMINATION CAP ROOF LOCATI...

Страница 5: ...MATERIAL PETS ETC IT IS IMPERATIVE THAT THE CONTROL COMPARTMENTS BURNERS AND CIRCULATING AIR PASSAGES OF THE APPLIANCE ARE KEPT CLEAN AND FREE OF OBSTRUCTIONS S ASSURER QUE LE BR LEUR ET LE COMPARTIME...

Страница 6: ...Warranted by Hearthstone Quality Home Heating Products Inc 317 Stafford Ave Morrisville VT 05661 8695 USA www hearthstonestoves com Figure 1 Champlain DV Dimensions Specification NG LP Input rating Bt...

Страница 7: ...of the Champlain will reach high temperatures during normal operation Clearances to combustibles must be maintained as specified in the Clearances To Combustibles section of this manual Due to high t...

Страница 8: ...ontrol valve access door 10 Plug in the blower accessory if so equipped 11 Set thermostat to ON and set the desired temperature setting Normally if the T STAT position was selected the main burner is...

Страница 9: ...st equip pour des altitudes compries entre 0 et 2000 pieds 0 610 m seulement UNPACKING AND INSPECTION Unpack and Inspect for Damage Hearthstone packages the Champlain to withstand normal shipment with...

Страница 10: ...ve these two screws and replace them with the two decorative caps provided with the unit 6 To re install reverse the outlined steps above ITEMS REQUIRED FOR INSTALLATION External regulator for LP Phil...

Страница 11: ...BY LOCAL CODES THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED KIT IS USED AVAILABLE TH...

Страница 12: ...her direction for installation please refer to the venting instructions provided with the venting components VENT CONNECTION The Champlain Direct Vent Model 8301 is approved for installation only with...

Страница 13: ...recommend 12 inches particularly where strong winds prevail H Not to be installed within 15 feet 4 5m above a meter regulator assembly within 3 feet 91cm horizontally from the center line of the regu...

Страница 14: ...e elbow so that the twist lock end is pointing straight up Install the 2 pipe section into this elbow by fully inserting it and turning approximately turn clockwise until the two sections are fully lo...

Страница 15: ...ll thickness for this configuration is 3 min to 9 max II FIREPLACE VENTING INSTALLATIONS 40 maximum system height without offsets 14 maximum offset refer to Figures 10 12 Maximum rise to run 1 to 5 re...

Страница 16: ...to run 1 to 5 The termination must meet the requirements outlined in Figure 8 9 Use a vinyl siding Stand off when installing against vinyl siding Horizontal sections require a 1 4 rise every 12 of ho...

Страница 17: ...8301 Figure 13 Venting Configuration and Restrictor Settings VENT RESTRICTOR To adjust your restrictor for maximum flame appearance loosen the phillips head screw and spin the locator found on the re...

Страница 18: ...ressure and manifold gas pressure must be tested The gas control valve has built in pressure taps for test gauge connections The supply line pressure must be tested to ensure it meets the minimum pres...

Страница 19: ...nd stove parts reduced efficiency and high levels of carbon monoxide If the log set does not fit into the firebox exactly as outlined contact your dealer for assistance INSTALLATION OF THE LOG SET CAU...

Страница 20: ...e embers into the burner holes Locate and open the bag of Platinum Bright Embers Pull apart small pieces of the wool and sprinkle over the Charcoal Embers randomly This wool will glow brightly once th...

Страница 21: ...r all around the appliance area to check for gas leaks Be sure to test near the floor because some gases LPG are heavier than air and will settle on the floor If you detect gas check for leaks WARNING...

Страница 22: ...ONLY A QUALIFIED GAS TECHNICIAN SHOULD DO THE CONVERSION For checking and properly adjusting the manifold pressure refer to the Gas Connection section on page 17 of this manual Leak test before and af...

Страница 23: ...he thermocouple and thermopile Turn the unit off by setting the switch to Off and turning off the gas control valve Allow the unit to cool Check and clean any burner ports that are not burning or not...

Страница 24: ...ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING ATTENTION AU MOMENT DE L ENTRETIEN DES COMMAN...

Страница 25: ...TER 3160 157 GASKET 6 7211 221 BURNER ASSEMBLY 3160 300 PRIMARY AIR CONTROL GASKET 7211 430 IGNITER ELECTRODE 3170 150 PLATINUM BRIGHT EMBERS 7211 470 THERMOCOUPLE 5300 066 PIEZO BRACKET 7211 601 BOTT...

Страница 26: ...3 57010 This appliance is only for use with the type of gas indicated on this rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by l...

Страница 27: ...embly may be dirty E Clean or replace the pilot assembly 2 Pilot will not stay lit after carefully following lighting instructions A Low or too high gas pressure A Check for proper inlet pressure for...

Страница 28: ...er does not come on replace the gas valve C Plugged burner orifice C Remove and check burner orifice clean or replace Note do not use any metal cleaning device as this may damage the orifice 4 Pilot a...

Страница 29: ...f gas pressures are correct and the flames stay the same adjust the air shutter for a proper burn 9 Burner flashback Air gas mixture ignites inside the burner near the orifice usually creating a roari...

Страница 30: ...ed and signed Warranty Registration Form which is enclosed in the Gas Stove warranty packet to the following address Hearthstone Quality Home Heating Products Inc Warranty Department 317 Stafford Aven...

Отзывы: