HearthStone Bristol DX Скачать руководство пользователя страница 32

Hearthstone Quality Home Heating Products, Inc.

                                                   

          

Bristol Model 8762  

 

 

 

32 

Some  conditions  cannot  be  corrected  through  air 
shutter  adjustment; an adjustment must be made to 
the  gas  supply  pressure  or  by  changing  the 
restriction  plate  setting.  Qualified  service  personnel 
must  perform  supply  line/manifold  gas  line  pressure 
adjustments and restrictor plate adjustments. Do not 
attempt  to  complete  any  part  of  the  installation  or 
adjustment of this unit unless technically qualified. 

Air Shutter Adjustments 

 

WARNING: THE ADJUSTING STUDS ARE HOT!  

 

 

WARNING:  THE  AIR  SHUTTERS  ARE  FACTORY 
SET  AND  ONLY  A  QUALIFIED  GAS  TECHNICIAN 
SHOULD MAKE ADJUSTMENTS.  

The  air  shutters  are  adjustable  while  the  stove  is 
burning.  Move  the  shutter  left  or  right  to  adjust  the 
flame  pattern. 

See  Figures  30  and  31.

  Move  the 

shutter towards the valve to open the air shutter, and 
away to close the shutter.  When the flame pattern is 
correct, tighten the set nut without letting the shutter 
move.   

 

Figure 29 - Air Shutters Closed 

 

Figure 30 - Air Shutters Opened 

Note: 

Very little movement is needed to substantially 

change  the  burn  and  flame  patterns.  Some 
conditions  cannot  be  corrected  through  air  shutter 
adjustment; an adjustment must be made to the gas 
supply  pressure.  Supply  line/manifold  gas  line 
pressure  adjustments  must  be  performed  by 
qualified  service  personnel.    Do  not  attempt  to 
complete any part of the installation or adjustment of 
this unit unless technically qualified to do so. 

Burner Flame Appearance 

Once  the  unit  is  lit,  observe  the  flame  pattern  and 
adjust as necessary.  Also, a periodic visual check of 
the  burner  flame  should  be  performed.  The  burner 
flames can be adjusted by means of the air shutter.  
To  determine  if  the  burner  flame  needs  adjustment, 
it  is  necessary  to  view  the  flame  pattern  with  the 
valve  output  at  its  highest  setting.  Allow  the  unit  to 
operate  for  10  minutes  enabling  the  entire  unit  to 
reach  temperature  and  for  the  flame  pattern  to 
stabilize.  The  flame  pattern  should  be  similar  to  the 
one shown in Photo 9. There are several guidelines 
to aid in determining if the flame pattern is correct: 

1.  The  flame  should  not  be  dirty,  smoky,  sooty,  or 

lick the top of the stove. 

2.  The  flame  should  not  rise  off  the  burner;  this  is 

called “lifting”. 

3.  Flames  should  not  impinge  heavily  on  the  log 

set.  They  sho

uld  “fit”  through  the  pre-formed 

spaces designed in the log set. 

 

 

 

Photo 9 

– Typical Burner Flame Appearance 

Daily Operation 

Your Bristol gas-fired heater is easily operated once 
installed 

and 

adjusted 

by 

qualified 

service 

personnel. 

The 

unit 

is 

controlled 

via 

the 

Содержание Bristol DX

Страница 1: ...ent or 911 A qualified installer service agency or gas supplier must perform installation and service of this appliance In the Commonwealth of Massachusetts all installation of gas lines and gas fitti...

Страница 2: ...Intentionally Blank...

Страница 3: ...y Keep your original receipt in a safe place as proof of purchase Serial Number Fuel type Natural Gas Liquid Propane Sold by Date of Purchase Address Phone E mail Website Installed by Date of Installa...

Страница 4: ...tibles 16 Hearth Requirement Floor Protection 16 VENTING INFORMATION 18 Venting Components 18 Minimum Venting Installation Instructions 22 ELECTRICAL SYSTEM INFORMATION 25 GAS SUPPLY CONNECTIONS 26 Ga...

Страница 5: ...backup for functionality during power outages 6 Blower Assembly 7 Optional Screen Kit The Proflame GTMFS System Features 1 Thermostatic Remote Control a Six 6 flame levels adjustable via the remote b...

Страница 6: ...m furniture draperies clothing and flammable material Vent Only to the Outside Never vent the gas heater to other rooms or buildings Service Caution If you believe your Bristol is not in any way perfo...

Страница 7: ...OUND UNDER AND BEHIND THE UNIT ON A REGULAR BASIS TO PREVENT THE ACCUMULATION OF DUST AND LINT Ceramic Logs Burner If the decorative ceramic log or burner material supplied with the Bristol is damaged...

Страница 8: ...all functional abilities as well as a childproof lockout and low battery indicator It displays room temperature readout set temperature readout and function status The remote transmitter is powered b...

Страница 9: ...mode Smart mode means that as the room temperature approaches the limit set for shut down the valve will automatically gradually step down the flame height The reverse happens when the room cools the...

Страница 10: ...I Using the IPI mode is a more efficient use of fuel as the pilot only ignites when the thermostat calls for heat To switch back and forth between the two pilot modes 1 Press the OFF button on the rem...

Страница 11: ...er the Manual or Smart thermostatic control UP Down Arrow Key Adjusts the thermostat temperature range flame settings split flow and fan speed Mode Key Toggles through the component to be controlled s...

Страница 12: ...Street Room 1511 Boston MA 02202 www mass gov Figure 8 Model 8762 Dimensions Inches Specification NG LP INPUT RATING Btu hr 0 2000 ft 0 610 m 36 000 33 000 INPUT RATING Btu hr 2000 4500 ft 610 1370 m...

Страница 13: ...S SE SERVIR DE CET APPAREIL S IL A T PLONG DANS L EAU COMPL TEMENT OU EN PARTIE APPELER UN TECHNICIEN QUALIFI POUR INSPECTOR L APPAREIL ET REMPLACER TOUTE PARTIE DU SYST ME DE CONTR LE ET TOUTE COMMAN...

Страница 14: ...accessory boxes removed and set aside remove the 4 lag bolts and clips that fasten the unit to the pallet see figure 10 Take care not to mar or chip the stove s finish Have someone help lift the stov...

Страница 15: ...Slots 3 If installed remove the front screen by lifting it off the glass frame 4 Pull forward and disengage the spring clips securing the top of the glass frame See Figure 14 Tilt the top of the glass...

Страница 16: ...ipe Ensure you consider the need for access to the gas control valve access door on the front of the unit as well as full access for periodic cleaning and servicing Also consider clearance for the blo...

Страница 17: ...hstone Quality Home Heating Products Inc Bristol DX Model 8762 17 The corner clearance for the Bristol 8762 is 11 measured from the edge of the top castings to the adjacent wall Figure 16 Corner Clear...

Страница 18: ...Configurations WARNING IN HIGH WIND AREAS AND PARTICULARLY COLD CLIMATES IT MAY BE NECESSARY TO HEAT YOUR VENT SYSTEM WITH THE PILOT PRIOR TO IGNITION OF THE MAIN BURNER IN THESE INSTANCES IT IS RECOM...

Страница 19: ...himneys The following installation requirements must be followed The termination must fall within the chart shown in Figure 24 In a masonry chimney a fireclay liner or listed steel liner must be prese...

Страница 20: ...sitioned to maintain 2 minimum clearance at the top A 1 minimum clearance must be maintained to combustible materials around the other sides All horizontal terminations must also comply with the clear...

Страница 21: ...m CAN We strongly recommend 12 inches particularly where strong winds prevail H Not to be installed within 15 feet 4 5m above a meter regulator assembly within 3 feet 91cm horizontally from the center...

Страница 22: ...of the retaining straps extend through interior wall thimble Before attaching the vent termination to the outside of the house run a bead of non hardening mastic around its outside edges so as to mak...

Страница 23: ...sition The restrictor plate is factory set in the fully opened position for shipping This ensures proper flames for a wide variety of vent configurations and efficiency The restrictor consists of a sl...

Страница 24: ...Hearthstone Quality Home Heating Products Inc Bristol DX Model 8762 24 Figure 23 Venting Termination Diagram...

Страница 25: ...G ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING ATTENTION AU MOMENT DE L ENTRETIEN DES COMMANDES TIQUETEZ TOUS LES FILS AVANT LE D BRANCHEMENT DES ERREURS D...

Страница 26: ...LEAK TEST THE UNIT BEFORE IT IS APPROVED FOR USE CONSULT ALL CODES WARNING THE UNIT MUST BE INSTALLED AND CONNECTED IN ACCORDANCE WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WITH THE MOST CURREN...

Страница 27: ...nnected to the gas supply the supply line and manifold gas pressures must be tested The supply line pressure is tested to ensure it meets the minimum gas supply pressure as listed in the specification...

Страница 28: ...d to rough or improper handling Exact positioning of the log set is required in order to obtain a pleasing flame pattern and efficient combustion Incorrect log placement may cause carbon build up exce...

Страница 29: ...reen by its folded lip on top of each glass frame Removal of Log Set CAUTION THE LOG SET BURNER AND EMBERS RETAIN HEAT AND CAN BE VERY HOT ALLOW 2 TO 3 HOURS TO COOL AFTER PILOT LIGHT IS TURNED OFF FO...

Страница 30: ...electrical circuit that has a dimmer switch anywhere in it fan speed modulation will be affected 1 Open the gas supply to the valve 2 Slide the ON REMOTE OFF switch to the ON position 3 Switch the pil...

Страница 31: ...of the pilot light adjustment screw located on the gas control valve Controlling the Bristol may become erratic nonexistent or the unit may go out if the pilot flame is too small or misdirected away...

Страница 32: ...n adjustment must be made to the gas supply pressure Supply line manifold gas line pressure adjustments must be performed by qualified service personnel Do not attempt to complete any part of the inst...

Страница 33: ...from the pilot is not wasted When putting the unit back into service replace any batteries with fresh ones and refer to the lighting instructions on page 30 Note the unit will produce odors for a shor...

Страница 34: ...per the instructions provided in the venting section of this manual Annually Clean Firebox Pilot Burner Assembly The firebox requires periodic cleaning to prevent the accumulation of dust lint and ot...

Страница 35: ...nize with the Remote Control 3 Install three AAA batteries in the Remote Control and push the ON button The Receiver will beep four times to indicate the Remote s command is accepted and is set to the...

Страница 36: ...avoid bending the frame or breaking the glass 7 Remove the existing gasket from each piece of glass by grasping one end and pulling firmly Clean off as much of the hanging fiber hairs as possible 8 L...

Страница 37: ...p 7211 125 IFC Wire Harness User 3160 105 Delayed Ignition Relief Gasket Rear 7211 126 IFC Wire Harness Valve 3160 081 x 1 8 Gasket Tape 7211 127 IFC Wire Harness Splitflow 3170 150 Platinum Bright Em...

Страница 38: ...roper inlet pressure for the fuel gas in use B Check connections on the valve C Clean or replace the pilot assembly 3 Pilot burning no gas to one or both burners ON REMOTE OFF switch in the ON positio...

Страница 39: ...rate at which the combustion air is delivered Poor draft results in insufficient air delivery or a restricted exhaust Correct air intake exhaust flow system B1 Clear ports B2 Clear obstructions B3 Cle...

Страница 40: ...Hearthstone Quality Home Heating Products Inc Bristol Model 8762 40 Rating Label...

Страница 41: ...stoves com or send a completed and signed Warranty Registration Form which is enclosed in the Gas Stove warranty packet to the following address Hearthstone Quality Home Heating Products Inc Warranty...

Отзывы: