HearthRite HB20MN-1 Скачать руководство пользователя страница 8

8

INSTALLATION

Figure 11 - Mounting  Heater  Onto
Mounting  Bracket

Figure 9 - Folding  Anchor

Figure 10 - Popping  Open  Anchor
Wing  For  Thin Walls

Attaching  Mounting  Bracket  to
Wall
Note: 
 Wall  anchors,  mounting
screws,  and  spacers  are  in
hardware  package.  The
hardware  package  is  provided
with  heater.
Attaching  To  Wal l Stud  Method

For  attaching  mounting  bracket
to  wall  studs

1.   Drill  holes  at  marked  locations
      using  9/64

"

  drill  bit.

2.   Place  mounting  bracket  onto
      wall. Line up last hole on each
      end of bracket with holes drilled
      in wall.
3.   Insert mounting screws  through
      bracket and into wall studs.
4.   Tighten screws until mounting
      bracket is firmly fastened to
      wall studs.
Attaching  To  Wall  Anchor Method
For  attaching  mounting  bracket to
hollow  walls  (wall  areas between
studs) or solid  walls (concrete or
masonry)
1.   Drill holes at marked  locations
      using  5/16

"

 drill bit.  For  solid

      walls  (concrete  or masonry),
      drill  at  least 1

"

  deep.

2.   Fold wall  anchor as  shown in
      Figure 9  below.

3.    Insert  wall  anchor  (wings
       first) into hole. Tap  anchor
       flush  to  wall.
4.    For  thin  walls (1/2

"

  or  less),

       insert  red  key  into  wall
       anchor.  Push  red  key  to
       

"

pop

"

  open  anchor  wings.

      (see  Figure  10).

           IMPORTANT:  Do  not
hammer    key!   For thick walls
(over  1/2

"

  thick)  or  solid  walls,

do  not  pop  open wings.

5.   Place  mounting  bracket  onto
       wall.  Line  up  last  hole  on
       each end  of  bracket  with wall
       anchors.
6.   Insert  mounting  screws through
      bracket  and  into  wall anchors.
7.   Tighten  screws  until  mounting
      bracket  is  firmly  fastened  to
      wall.

Placing  Heater  On  Mounting

Bracket

1.   Locate  two  horizontal   slots  on
    back  panel  of  heater (see
      Figure 11).
2.  Place  heater  onto  mounting
     bracket.  Slide  horizontal  slots
    onto   stand-out    tabs    on
      mounting  bracket.

Installing  Bottom  Mounting
Screws
1.   Locate  two  bottom  mounting
      holes. These  holes  are  near
       bottom    on      back     panel   of
        heater(see Figure 12).

2.   Mark       screw     locations     on
      wall.
3.   Remove   heater   from   mounting
      bracket.
4.  If  installing  bottom  mounting
       screws into   hollow  or  solid  wall,
      install  wall anchors.  Follow  steps
      1  through  4   under   

Attaching  To

      Wall  Anchor  Method

.  If  installing

       bottom     mounting     screw    into
        wall  stud,   drill   holes   at   marked
      locations  using  9/64

"

  drill  bit.

5.   Replace  heater  onto  mounting
      bracket.
6.  Place        spacers       between
      bottom     mounting     holes    and
    wall anchor  or  drilled  holes.
7.    Hold  spacer  in  place  with       one
     hand. With  other  hand,  insert
       mounting         screw         through
     bottom    mounting   hole   and
     spacer.  Place tip  of  screw  in
       opening          of        wall      anchor
      or  drilled  holes.
8.   Tighten  both  screws  until heater
      i s     f i r m l y       s e c u r e d       t o
      wall. Do not over  tighten.

 

Note:  Do  not  replace  front panel

    at  this  time. Replace  front
      panel      after      making      gas
     connections  and  checking  for
       leaks (see  pages  8 and 9).

Figure 12 - Installing Bottom
Mounting Screws

Содержание HB20MN-1

Страница 1: ...upplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or gas supplier ImportantSafetyInformation 2 Product Features 3 Proper Ventilation FreshAir 4 Installation 6 OperatingYour Heater 10 Cleaning Maintenance 13 Trouble Shooting 14 Specifications 17 Parts List 19 WarrantyInformation 22...

Страница 2: ...s Surface of heater becomes very hot when running heater Keep children and adults away from hot surface to avoid burns or clothing ignition Heater will remain hot for a time after shuting down Allow surface to cool before touching Carefully supervise young children when they are in the same room with heater Make sure grill guard is in place before running heater 8 Turn heater off before using furn...

Страница 3: ...eater from carton 2 Remove all protective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater QUALIFIED INSTALLING AGENCY Installation and replacement of gas piping gas uti lization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency The term qual...

Страница 4: ...tion air by one of the methods described in the National Fuel Gas Code ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction l you must provide additional fresh air Unusually tight construction is defined as constructio...

Страница 5: ...in the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used Btu Hr maximum the s...

Страница 6: ...t shutoff valve ground joint union test gauge connection sediment trap tee joint pipe wrench A CSA AGA design certified equip ment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CSA AGA design certified equip ment shutoff valve from your dealer LOCATING HEATER This heater is designed to be mounted on a wall You can locate heater on floor away from...

Страница 7: ...ard then down see Figure 7 Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall These two holes are 16 inches apart from center Attach mounting bracket to wall o n l y i n o n e o f t w o w a y s 1 Attaching to wall stud 2 Attaching to wall anchor Attaching To Wall Stud This method provides the strongest hold Insert mounting sc...

Страница 8: ...lace mounting bracket onto wall Line up last hole on each end of bracket with wall anchors 6 Insert mounting screws through bracket and into wall anchors 7 Tighten screws until mounting bracket is firmly fastened to wall Placing Heater On Mounting Bracket 1 Locate two horizontal slots on back panel of heater see Figure 11 2 Place heater onto mounting bracket Slide horizontal slots onto stand out t...

Страница 9: ...union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 13 A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CSA AGA design certified equipment shutoff valve from your dealer IMPORTANT Install an equipment shutoff valve in an accessible locat...

Страница 10: ...om equipment shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operating Heater pages 10 and 11 for thermostat models or page 12 for non thermostat models Check the rest of the intemal joints for leaks 7 Turn off heater see To Turn Off Gas to Appliance page 11 for thermostat m...

Страница 11: ...e lighting pilot again 8 Turn control knob counterclockwise to desired heating Level The main burner should light Set control knob to any heat level between HI and LO THERMOSTAT CONTROL OPERATION The thermostatic control used on these models differs from standard thermostats Standard thermostats simply turn on and off the burner The thermostat used on this heater senses the room temperature The th...

Страница 12: ... press in control turn control knob clockwise to the PILOT position Figure 18 Control Knob In The OFF Position Figure 19 Pilot 1 STOP Read the safety information on the side of heater 2 Make sure equipment shutoff valve is fully open 3 Push in control knob slightly and turn clockwise to the OFF position see Figure 18 4 Wait five minutes to clear out any gas Then smell for gas including near the fl...

Страница 13: ...the pilot flame comes out of the pilot assembly see Figure 24 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if com pressed air is not available Figure 24 Pilot Inlet Air Hole CLEANING HEATER CABINET Air Passageways Use a vacuum cleaner or pressurized air to clean Exterior Use a soft cloth dampened with a mild soap and water mixture Wipe the cab...

Страница 14: ...pment shutoff valve is not fully open 4 Thermocouple connection loose at control valve 5 Pilot flame is not touching thermo couple This allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor 2 Replace ignit...

Страница 15: ... expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance Page 13 or replace burner orifice 2 Replace burner orifice 3 Contact local natural gas company 1 Contact local natural gas company 2 Clean burner see Cleaning and Maintenance Page 13 or...

Страница 16: ... from paint hair spray glues etc See IMPORTANT statement above 2 G a s l e a k S e e W a r n i n g statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning Statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning Statement at top of page 1 Metal expandi...

Страница 17: ...ies from your local dealer If they can not supply these accessories contact HearthRite for information You can also write to the address listed on the front of this manual OptionalFANKit The optional fan kit part HAB01 fits all models noted in this manual The fan has 3 settings ON OFF Auto The thermostatically controlled HAB01 improves heater efficiency and in cludes installation and operating ins...

Страница 18: ...1 8 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS HB20TN HB30TN ...

Страница 19: ...etainer Lower Glass Retainer Self Tapping Screw Thermostat Valve Assembly Screws Thermosstat Valve Base Assembly Ignitor Assembly Ignitor Line Pressure Regulator Washer Self Locking Screw Main Inlet Tube Assembly ODS Line Assembly Burner inlet Tube Assembly Burner Burner Connector Injector Left Burner Support Bracket Right Burner Support Bracket ODS Thermocouple Ignitor Electrode ODS Upper Deflect...

Страница 20: ...2 0 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MODELS HB20MN HB30MN ...

Страница 21: ...f Tapping Screw Control valve Ignitor Line Control Knob Assembly Control Valve Fixed Nut Pressure Regulator Washer Self Locking Screw Main Inlet Tube Assembly ODS Line Assembly Lower Gas Outline Tube Assembly Medium Gas Outline Tube Assembly High Gas Outline Tube Assembly 4 Way Connector Burner Inlet Tube Assembly Burner Burner Connector Injector Left Burner Support Bracket Right Burner Support Br...

Страница 22: ...2 2 ...

Страница 23: ......

Страница 24: ......