14
HORIZONTAL VENTING
Kit No.
H Max. Run
DVK-01TRD
24" (610 mm)
Figure 11. Corner Installation
NOTE:
This model is NOT tested and NOT ap-
proved to use 45° elbows in corner installations.
90° elbows may be used in corner installations.
1 2 3 4 5
SETTING
1 2 3 4 5
Figure 10.
5
. Center the Flue Restrictor on vent and secure in
place by using two self-tapping screws on setting
#2 (see Figure 10).
45-DEGREE
ELBOW
90-DEGREE
ELBOWS
H
Figure 9. Flue Restrictor
BREAK
HERE
4.
Break the Flue Restrictor into two pieces. Do this
by bending the part back and forth until it breaks
(see Figure 9). This part is in the instruction bag
provided with the fireplace.
6
. Reinstall the Exhaust Shield.
7
. Reinstall the refractory pieces, installing rear re-
fractory first, then the sides.
NOTE:
Secure in place using #2 hole setting ONLY.
NOTE: There MUST be a 25% reduction in total
H when using flex vent.