Hearth Sense VF18LA-2 Скачать руководство пользователя страница 1

AMBILOG VENT-FREE GAS LOG HEATER

PFS

®

US

 

WARNING: If the information in this manual is not 

followed exactly, a fire or explosion may result causing 

property damage, personal injury or loss of life.
—  Do not store or use gasoline or other  flammable va-

pors and liquids in the  vicinity of this or any other 

appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do not use any 

phone in your building.

•  Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

—  Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

Questions, problems, missing parts?

 Before returning to your retailer, call 

our customer service department at 1-866-573-0674, 8:00 am - 4:30 pm CST, 

Monday through Friday or email

 [email protected]

MODELS

VF18NA-2

VF18LA-2

VF24NA-2

VF24LA-2

Содержание VF18LA-2

Страница 1: ...in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and serv...

Страница 2: ...n and Ventilation section on page 6 of this manual WARNING Improper installation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in s...

Страница 3: ...igns the heater may not be working properly Get fresh air at once Have heater serviced Some people are more affected by carbon monoxide than oth ers These include pregnant women people with heart or l...

Страница 4: ...ass doors closed If you operate heater with doors closed heat will build up inside fireplace and cause glass to burst If fireplace opening has vents at the bottom you must open the vents before operat...

Страница 5: ...rchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts the gas cock must be a T handle type The State of Massachusetts requires that a flexible appliance connector cannot exc...

Страница 6: ...y for the application including ample combustion air and circulation air 2 If high humidity is experienced a dehu midifier may be used to help lower the water vapor content of the air 3 Do not use an...

Страница 7: ...Maximum Btu Hr the space can support Example 2560 cu ft 72 49 m3 volume of space x 20 51 200 maximum Btu Hr the space can support Unusually Tight Construction The air that leaks around doors and windo...

Страница 8: ...l Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic ha...

Страница 9: ...re place If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper WARNING Never install the heater in a bedroom or bathroom in a recreational vehi...

Страница 10: ...SIZING REQUIREMENTS Minimum Firebox Size 18 Log Set Height 20 Depth 13 Front Width 26 Rear Width 20 24 Log Set Height 20 1 2 Depth 14 Front Width 30 Rear Width 22 Minimum Clearances For Side Combusti...

Страница 11: ...is less than 12 you must install the fireplace hood accessory Even if noncombustible material is more than 12 you may need the hood accessory to deflect heat away from your mantel shelf See Figures 5...

Страница 12: ...not permit vent free operation 3 You prefer vented operation If reasons number 1 or 2 above apply you must permanently open chimney flue damper You must install the damper clamp accessory not provided...

Страница 13: ...ly to fitting threads Connect approved flexible gas hose to gas regulator of heater see Figure 11 Note Never apply pipe sealant to flare fitting threads Hold gas regulator with a wrench when connectin...

Страница 14: ...eptable al ternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING A qualified ser vice technician must connect heater to gas sup...

Страница 15: ...4 WC If you do not reduce incom ing gas pressure heater regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 14 Pointing the vent down protects it fro...

Страница 16: ...ts for Natural Gas Gas Meter WARNING Testallgaspiping and connections internal and external to unit for leaks after installing or servicing Correct all leaks at once WARNING Neveruseanopen flame to ch...

Страница 17: ...MILLIVOLT CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous opera tion Verify proper operation after servicing Note The millivolt v...

Страница 18: ...s number will help you to identify the logs when installing After installing logs add decorative cinders around the grate base do not place any decorative cinders on logs or burner 1 Insert log 1 into...

Страница 19: ...mproper burning will result During manufacturing fabricating and ship ping various components of this appliance are treated with certain oils films or bonding agents These chemicals are not harmful bu...

Страница 20: ...his heater has a safety in terlock system Wait one 1 minute before lighting pilot again 8 Turn control knob counterclockwise to the ON position The main burner should light Set control knob to the de...

Страница 21: ...e REMOTE position Note The burner may light if hand held re mote was on when selector switch was last turned off You can now turn the burner on and off with the hand held remote control unit IMPORTANT...

Страница 22: ...se the thermocouple to cool which shuts the heater off If pilot flame pattern is incorrect as shown in Figure 27 or 29 turn heater off see To Turn Off Gas to Ap pliance page 20 see Troubleshooting pag...

Страница 23: ...t assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner pilot and primary air inlet holes on injector for dust and dirt see Figure 32 3 B...

Страница 24: ...tor button is pressed in there is no spark at ODS pilot 1 Ignitor electrode is posi tioned wrong Ignitor elec trode is broken 2 Ignitor electrode is not con nected to ignitor cable 3 Ignitor cable is...

Страница 25: ...rner orifice is clogged 2 Burner orifice diameter is too small 3 Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 23 or replace burner orifice 2 Replace burner orific...

Страница 26: ...lls or furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar produ...

Страница 27: ...nty coverage for parts replaced under warranty PARTS UNDER WARRANTY PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call Customer S...

Страница 28: ...www usaprocom com 200067 01A 28 PARTS MODELS VF18NA 2 VF18LA 2 VF24NA 2 AND VF24LA 2 5 3 2 1 12 13 8 7 6 4 10 11 9 5 14 8 1 14 1 14 3 14 5 14 6 14 7 14 2 14 4 14 8 2 14 8 3 14 8 4 14 8 5 14 8 6...

Страница 29: ...Pilot 1 8 RV81FI 3 RV81FI 3 Gas Pressure Regulator 1 9 PIMSC1 01 PIMSC1 01 PIMSC1 01 PIMSC1 01 Electronic Piezo Ignitor 1 10 RG01 1L RG01 1L RG01 1L RG01 1L Ambiance LightAssembly 1 11 RG01 1L B RG01...

Страница 30: ..._________ ________________________________________________________________________ ________________________________________________________________________ ____________________________________________...

Страница 31: ..._________ ________________________________________________________________________ ________________________________________________________________________ ____________________________________________...

Страница 32: ...ller in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERED This warranty does not apply to parts that are not in original condition because of normal wear and...

Отзывы: