CASTILE INS
NOTE:
The volt meter must have one lead connected to the white neutral wire from the power supply to be able to
read the correct voltage at the snap disc.
6
Convection Blower
ARE FUSES
GOOD?
ARE THE WIRE
CONNECTIONS
GOOD?
PLUG IN STOVE
IS THEIR
POWER PRESENT
ON BOTH SIDES?
IS THE BLOWER
RUNNING?
YES
NO
SYSTEM IS
REPAIRED
CHECK VOLTS
TO BLOWER. IS
THERE 95 VAC
OR HIGHER?
REPLACE THE WIRE
HARNESS
REPLACE THE
CONVECTION
BLOWER
YES
YES
YES
YES
NO
NO
NO
NO
REPLACE THE FUSES
REPLACE THE
CONTROL BOX
TECH TIP
INSTALLING A JUMPER
WIRE ON THE #1 SNAP
DISC PURPLE WIRES AND
THEN PLUGGING IN THE
APPLIANCE WILL TURN
ON THE BLOWER