background image

3

Hearth & Home Technologies  •  Pilot/Burner Conversion Instructions  •  2205-937 Rev. C  •  4/15

Explosion Risk
•  Pilot must be reattached to pilot bracket.

WARNING

•  Delayed ignition or an explosion may occur if the pilot is 

not attached to the pilot bracket.

27.  Use two screws to secure the pilot assembly on top of 

the pilot bracket located on the burner.  See Figure 4. 

28.  Reinstall base pan and grate assembly.  Reinstall 

refractory if previously installed.

29.  Reinstall logs by following log placement instructions 

located in the appliance installation manual.

19. Turn on 

fi

 replace with the green wire disconnected 

from the valve.  See Figure 3.

20. Use a commercially available, noncorrosive leak check 

solution to test for leaks around the pilot. Be sure to 
rinse off all leak check solution following testing. See 
Figure 5 for leak check points. Extinguish the pilot.

21.   Bend pilot shield.  See Figure 9 and Figure 10.
22.  Install the new pilot shield around the pilot assembly.  

Fasten with a screw in the existing left hole.  Be sure 
to use a screw to 

fi

 ll the unused hole to the right of the 

pilot assembly.  Use the existing valve plate screw to 
secure the right side.  See Figure 9 and Figure 10.

23. 

NDI30 and NDI35 Only: 

 Remove pilot bracket from 

the existing burner and discard.  Install the new pilot 
bracket.  See Figure 7 and Figure 8.  

24.  After pilot shield has been removed, replace open holes 

with screws.  There should be no pilot shield put in place 
on the GRAND-I35-C (LP).  See Figure 9.

25. See chart below for air shutter settings.  More informa-

tion regarding air shutter settings is available in the 
appliance installation manual.

Figure 7. New Pilot Bracket

NDI30/NDI35  ONLY

Figure 8.  New Pilot Bracket Installed

Figure 10.  Pilot Shield Top View 

Figure 9.  Pilot Shield Front View

FILL 

FILL OPEN HOLE 

OPEN HOLE 

WITH SCREW 

WITH SCREW 

PILOT 

PILOT 
SHIELD

SHIELD

BEND 

BEND TO 90 

TO 90 

DEGREES

DEGREES

NDI30/NDI35  ONLY

PILOT BRACKET 

SCREWS

30.  Reinstall the glass and the doors.
31.  Reconnect the green wire to the valve. See Figure 3.
32. Turn the 

fi

 replace “On” and use a commercially avail-

able, non-corrosive leak check solution to test for leaks 
around the pilot tube/

fi

 tting and valve.  Be sure to rinse 

off all leak check solution following testing and prior to 
placing the appliance into operation.  Turn the 

fi

 replace 

“Off” to extinguish pilot and main burner 

fl

 ame.

33. Reinstall the control panel.  See Figure 2.

USE 

USE EXISTING 

EXISTING 

HOLE

HOLE

EXISTING 

EXISTING 

VALVE 

VALVE 

PLATE SCREW

PLATE SCREW

Air Shutter Settings

NG

LP

3/8 in.

1/2 in.

26. Install the new burner so that the back of the burner 

slides under the pilot sensor rod and the burner ori

fi

 ce 

is surrounded by the burner tube.  Secure burner with 
one screw in the back right corner as shown in Figure 4.  

Содержание GRAND-I35-PILOT

Страница 1: ...cket NDI30 NDI35 Only Burner Neck Gasket NDI30 NDI35 Only Grommet LP Pilot Orifice Base Pan Pilot Shield Burner Not included with NDI30 NDI35 CAUTION THE GAS SUPPLY SHALL BE SHUT OFF PRIOR TO DISCONNECTING THE ELECTRICAL POW ER BEFORE PROCEEDING WITH THE CONVERSION Procedure for conversion 1 INTELLIFIRE PLUS MODELS ONLY This step is not applicable for NDI30 NDI35 Switch control module to OFF mode ...

Страница 2: ... Unscrew the pilot tube fitting on the new pilot and replace the orifice spud with the similar one included in the conversion kit See Figure 5 Figure 6 Proper Pilot Tube Bend Radius No Sharp Bends GREEN GREEN WIRE WIRE NOTE NOTE APPEARANCE APPEARANCE OF VALVE MAY VARY OF VALVE MAY VARY 14 Connect pilot tube to the valve assembly See Figure 3 Keep the pilot tube clear of the fan blades and ensure t...

Страница 3: ...he new pilot bracket See Figure 7 and Figure 8 24 After pilot shield has been removed replace open holes with screws There should be no pilot shield put in place on the GRAND I35 C LP See Figure 9 25 See chart below for air shutter settings More informa tion regarding air shutter settings is available in the appliance installation manual Figure 7 New Pilot Bracket NDI30 NDI35 ONLY Figure 8 New Pil...

Страница 4: ...rner should shut OFF 5 Turn fireplace OFF Reattach green wire to valve Turn fireplace ON Pilot and main burner should turn on 6 With the main burner ON remove orange wire con nected to the valve The pilot and burner should go out and the pilot will start to spark 7 Turn fireplace OFF and reattach orange wire to the valve Please contact your Hearth Home Technologies dealer with any questions or con...