Hearth & Home Technologies • B41L-AU Owner Manual • 2570-981 Rev. B • 5/20
10
Figure 3.3 Good Faith Wall Surface Temperatures Above Appliance
E. Good Faith Wall Surface/TV Guidelines
NOTICE:
Surface temperatures listed above are taken with
a temperature measuring probe as prescribed by the test
standard used for appliance certification. Temperatures
on walls or mantels taken with an infrared thermometer
may yield increased temperatures of up to 30 °F (17 °C)
or
more depending on the thermometer settings and material
characteristics being measured. Use appropriate finishing
materials that are able to withstand these conditions.
For additional finishing guidelines, see Section 10 in the
appliance installation manual.
Figure 3.4 Good Faith Wall Surface Temperatures Above Appliance
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
6 in.
18 in.
24 in.
30 in.
36 in.
48 in.
TO CEILING
42 in.
12 in.
194 °F
APPLIANCE FRONT
FIREPLACE
OPENING
142°F
119°F
110°F
105°F
101°F
98°F
95°F
(90 °C)
(61 °C)
(48 °C)
(43 °C)
(41 °C)
(38 °C)
(37 °C)
(35 °C)
(152 mm)
(305 mm)
(457 mm)
(610 mm)
(762 mm)
(914 mm)
(1067 mm)
(1219 mm)
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
6 in.
18 in.
24 in.
30 in.
36 in.
TO CEILING
12 in.
145°F
APPLIANCE FRONT
FIREPLACE
OPENING
120°F
109°F
104°F
95°F
95°F
OPTIONAL PASSIVE HEAT KIT INSTALLED
(63 °C)
(49 °C)
(43 °C)
(40 °C)
(35 °C)
(35 °C)
(152 mm)
(305 mm)
(305 mm)
(610 mm)
(762 mm)
(914 mm)