background image

10

Figure 12.  Standing Pilot Ignition Wiring Diagram

Figure 11.  Intermittent Pilot Ignition (IPI) Wiring Diagram

BLACK S2

ON

OFF

ON/OFF

SWITCH

WHITE T2

RED T1

THERMOPILE

GAS VALUE

BLACK S1

3/16” PIGGYBACK CONNECTOR

THERMOCOUPLE

REMOTE SWITCH

PIGTAIL

OPTIONAL WALL SWITCH,

THERMOSTAT OR REMOTE

IGNITION MODULE

3 VAC

TRANSFORMER

3 VAC

GR

N

OR

G

INTERMITTENT

PILOT

IGNITOR

IGNITION

MODULE

(3V)

ON/OFF

WALL

SWITCH

LOW VOLTAGE

PLUG-IN

3V TRANSFORMER

NEUTRAL

HOT

GROUND

FLAME SPARKER/

SENSOR

REMOTE

CONTROL

SEE NOTE 1

ORG

WHT

VALVE

PIGGYBACK

ON/OFF SWITCH

WHITE WIRE

CAN BE

PLUGGED

INTO ANY

OF #1-#5

LOCATIONS

ON THE

NEUTRAL SIDE

BLACK WIRE CAN BE

PLUGGED INTO ANY OF

#1 - #5 LOCATIONS

ON THE HOT SIDE

BR

N

BR

N

VALVE

PLUG IN

GROUND TO
FIREPLACE
CHASSIS

S

I

Содержание RCT-MLT-II

Страница 1: ...e done by a qualified service technician NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are desi...

Страница 2: ...the valve Adding Optional Fan Blower Plug 2 prong fan cord directly into the 3 prong polarized plug on the back of the receiver see Figure 3 This receptacle output is 110 120 VAC 3 AMP Wire Colors Ga...

Страница 3: ...damage may occur Wiring the Flame Controller 1 Connect the two leads from the flame control solenoid to the orange leads from the receiver 2 Install a manometer into the pressure tap 3 Plug the remot...

Страница 4: ...nsmitter is activated from a very cold condition it may be necessary to allow the transmitter to stabilize to room temperature could take up to 15 min utes before accurate room temperatures are displa...

Страница 5: ...CURRENT room temperature 8 F Indicates degrees Fahrenheit C indicates degrees Celsius 9 FAN Indicates fan is on or programmed to come on Three speed settings are available Transmitter Settings Flip o...

Страница 6: ...e kept away from direct sources of heat such as fire places incandescent lighting and direct sunlight Leaving the transmitter in direct sunlight for example will cause it to read the room temperature...

Страница 7: ...RATING MODES the transmitter sends a signal every fifteen 15 minutes to the receiver indicat ing that the transmitter is within the normal operating range of 20 feet Should the receiver NOT receive a...

Страница 8: ...n error whether performed by a contractor service company or owner is not covered by this warranty Seller will not be responsible for labor charges and or damage incurred in installation Timer Operati...

Страница 9: ...iring Diagram TRANSFORMER 3 VAC PLUG IN RED BATTERY PACK THERMOSTAT WIRE ASSEMBLY JUMPER WIRE TO BROWN ORANGE GREEN VALVE GROUND TO FIREPLACE CHASSIS WHITE ORANGE IGNITION MODULE 3 VAC INTERMITTENT PI...

Страница 10: ...THERMOSTAT OR REMOTE IGNITION MODULE 3 VAC TRANSFORMER 3 VAC GRN ORG INTERMITTENT PILOT IGNITOR IGNITION MODULE 3V ON OFF WALL SWITCH LOW VOLTAGE PLUG IN 3V TRANSFORMER NEUTRAL HOT GROUND FLAME SPARKE...

Страница 11: ...nition IPI Wiring Diagram Remote Control Wiring Diagrams VALVE GREEN ORANGE JUMPER WIRE TO BROWN PLUG IN TRANSFORMER 3 VAC BLACK RED GROUND TO FIREPLACE CHASSIS WHITE ORANGE INTERMITTENT PILOT IGNITOR...