background image

16

Condition (at time of power failure)

Result

The wall switch is in ON mode with the main fl ame on and it has 
battery backup

The fi replace will stay on and the main burner will turn to HIGH, 
the FOL* (Flame on a Log) will also have fl ame.  The display 
lights in the wall switch will be off and the fi replace can be turned 
on and off by pressing the mode button.

If the main fl ame is on when the power is restored to the system, 
it will return to the ON  mode and the display lights in the wall 
switch will come back on.

If the main fl ame is off when the power is restored to the system, 
it will go to OFF mode and the display lights in the wall switch will 
come back on.

*Not all units using this system have a FOL (Flame on a Log) 
feature.

The wall switch is in OFF mode with the main fl ame off and it has 
battery backup.

The fi replace main burner will stay off.  The display lights in the 
wall switch will be off and the fi replace can be turned on and off 
by pressing the MODE button.

If the main fl ame is on when the power is restored to the system, 
it will return to the ON mode and the display lights in the wall 
switch will come back on.

If the main fl ame is off when the power is restored to the system, 
it will go to OFF mode and the display lights in the wall switch will 
come back on.

TROUBLESHOOTING

 (

continued

)

The operating characteristics of your fi replace may vary during a power failure or power outage.  the options listed below 
will help determine the current state of your system.

SERVICE PARTS

DESCRIPTION

PART NUMBER

Wall Switch Wire

2095-550

Solenoid, Hi/Lo Flame

2101-029

Wall Control Assembly

2106-072

Control Box Assembly
(includes 1 cord assembly and 1 cable assembly)

2106-025

Содержание Multifunction Wall Control WSK300

Страница 1: ...nder it unusable and may lead to possible electrical shock Fire Hazard Modification of any parts or installation of dama ged components will void the warranty and you may possibly cause a fire hazard...

Страница 2: ...and blue and red plungers from the side of the flame control sole noid Place washer on flame control solenoid 4 Insert correct plunger blue natural gas red pro pane into the flame control solenoid Thr...

Страница 3: ...PILOT DEXEN IPI VALVE CONTROL MODULE SOLENOID J BOX 110V FAN WALL SWITCH BACK VIEW CORD ASSEMBLY 2 GRN BLK BLK JUMPER DETAIL B B FOR B VENT APPLIANCES BLU SEE DETAIL B B FOR B VENT APPLIANCES HIGH LI...

Страница 4: ...unit as close to the louvers or decorative front as possible and to either the left or right side 2 Connect the red yellow or white and green wires to the appropriate labeled terminals on the control...

Страница 5: ...o pilot functions PILOT ON will always be highlighted on display for cold climate pilot operation PILOT OFF will be displayed when in normal pilot operation for three seconds Use AUX button to toggle...

Страница 6: ...ntrol Specifications 6 Function CONTINUOUS DISPLAY SCREEN 4 2 34 4 0 4 4 2 3 4 2 4 0 6 4 2 3 4 54054 0 4 58 3 4 2 4 0 6 4 2 3 4 54054 0 4 At a continuous display mode LCD will only display the room te...

Страница 7: ...ivate the temperature scale change Fahrenheit icon will appear with the temperature level Press both arrow buttons for three seconds to change temperature scale between F and C 3 4 2 4 0 6 4 2 3 4 540...

Страница 8: ...ws to turn flame HI or LO Pressing the UP or DOWN arrow while the continuous display screen is shown will display the current flame size Wall Control HI Flame LO Flame Adjusting Flame Size Pressing UP...

Страница 9: ...ay Pilot flame will stay lit continuously 0 4 Press PILOT button 3 4 2 4 0 6 4 2 3 4 54054 0 4 PILOT icons will display Press button until OFF setting is highlighted Normal display will have no PILOT...

Страница 10: ...o lock any button press from changing the state of the fireplace or its features To cancel the Child Lockout Feature press and hold the button again for 3 seconds The control will beep twice again and...

Страница 11: ...to a maximum of 180 minutes Press DOWN arrow to decrease TIMER setting in 15 minute decrements to a minimum of 15 minutes To change TIMER settings while the TIMER is active press button twice Then Pre...

Страница 12: ...ode will automatically adjust fireplace Flame Size and Fan Speed based on the desired room temperature If AUX 1 Fan is pressed AUT will display on the screen When the control is first powered the THER...

Страница 13: ...ing THERMOSTAT mode This mode activates a FAN cool down feature that will continue to operate the fan until all remaining heat has been blown into the room Auxiliary A1 FAN may not be operated in the...

Страница 14: ...the line voltage power supply and then removing the batteries from the battery backup kit if it is at tached After one minute restore the line voltage power supply and the batteries The wall control s...

Страница 15: ...all switch will come back on the pilot will stay on and the fireplace will stay off The wall switch is in OFF mode with the main flame off and has no battery backup or has dead batteries The fireplace...

Страница 16: ...itch is in OFF mode with the main flame off and it has battery backup The fireplace main burner will stay off The display lights in the wall switch will be off and the fireplace can be turned on and o...

Отзывы: