Hearth & Home Technologies • IFT-RC400 & IFT-ACM Installation Instructions • 2326-982 Rev. Q • 4/21
2
Figure 1 Connect IFT-RFM to IFT-ECM
Figure 2 IFT-ECM
7. The IFT-ACM can provide power to HHT approved kits
including fan, lights and power vent.
•
To connect a fan kit to the IFT-ACM, insert the
three prong male plug from the fan into the re-
ceptacle located on the right side of the IFT-ACM.
See Figure 4.
•
To connect a light kit to the IFT-ACM, remove pro
-
tective rubber cap labeled ‘LIGHTS’ and connect
to the female cord that was supplied in your lights
kit into the three male pins on the IFT-ACM. See
Figure 4.
•
To connect a power vent kit to the IFT-ACM, re
-
move protective rubber cap labeled ‘AUX’ and
connect to the female cord that was supplied in
your power vent kit into the three male pins on the
IFT-ACM. See Figure 4.
6. Connect the IFT-ACM to the IFT-ECM by aligning the
pins and tabs and pushing the IFT-ACM onto the IFT-
ECM until both tabs latch in place. Ensure the IFT-
ECM and IFT-ACM are aligned with each other and
fastened securely. See Figure 3.
Figure 3 Connecting IFT-ACM and IFT-ECM
WARNING! Risk of Shock! DO NOT
touch male pins.
Leave rubber cap on all ports unless port is being con-
nected to an accessory kit.
Figure 4 Fan, Lights and Power Vent Connection
4. Remove protective rubber cap from connector on the
top of the IFT-ECM. See Figure 2.
‘OFF’ POSITION
WARNING! Risk of Shock! DO NOT
touch male pins.
Leave rubber cap on all ports unless port is being con-
nected to an accessory kit.
POWER CORD
POWER CORD
FAN
FAN
POWER
POWER
VENT
VENT
LIGHTS
LIGHTS
5. Attach velcro included with the IFT-ACM to the bottom
of the ACM. See Figure 3.
ATTACH VELCRO