2

Hearth & Home Technologies  •  

HZLIN-ADP 

Instructions  •  2600-972   •  5/19

 

Figure 4   Assemble the Heat-Zone

®

-Gas Components

Fan Housing

Round to Oval Adapter

6 in. Insulated

Round Air Duct

***DAMPER

DUCT COLLAR

**ATTACH WITH 

   ZIP TIE AT 

   DAMPER

 **USE THE INCLUDED ZIP TIE TO ATTACH THE FLEX

    DUCT TO THE DAMPER

***VERIFY DAMPER IS OPERATIONAL AND NO OBSTRUCTIONS, 

    SUCH AS SCREWS, ARE PRESENT

CRIMPED SIDE UP

4.  Center the duct collar, included with the Heat-Zone

®

-

Gas kit, around the open hole and attach it to the 

appliance with 3 screws included in the Heat-Zone

®

-Gas  

kit.  See Figure 4.

5.  Attach damper to the Heat-Zone

®

-Gas duct collar with 

three screws.  Install damper with the crimped side up.  

See Figure 4.

CAUTION!  Risk of Overheating! Risk of Burns! 

Damper 

must be installed.  Register will become hot in absence 

of damper.

NOTICE:  

Damper must be installed correctly or it will not 

function properly. 

6.  Verify the damper opens and closes properly. 
7.  Attach six inch duct to the damper using a zip tie.  See 

Figure 4.

8.  Use the power cord supplied with the Heat-Zone

®

-Gas 

kit  to plug the Heat-Zone

®

-Gas into the fan port on the 

auxiliary control module (ACM).  See Figure 5.

Refer to the Heat-Zone

®

-Gas Kit instructions for the

remaining installation steps.

Figure 3   Install Collar

3.  Place the collar, included with the HZLIN-ADP kit, into 

the opening as shown in Figure 3.