Hearth & Home Technologies  •  Heat-Zone-240V Air Duct Kit  •  299-900D  •  7/10

4

Figure 8

Figure 9

Figure 7

Operation

1.  Start the heater per instructions and allow it to warm 

up. 

2.  Turn the wall switch "ON" to start air fl ow at the air duct 

register or use RC300 remote to turn on blower.

Maintenance

1.  Service and maintain the gas heater per instructions.

2.  Keep the air register(s) clean and free of any blockage. 

3.  Reference IPI Plus instructions with remote control for 

fan auxiliary control.

STUD

BROWN HOT 

BROWN 

BLUE NEUTRAL

BLUE

YELLOW / GREEN

GROUND

GROUND

SWITCH 

JUNCTION BOX

FAN

JUNCTION BOX

FAN

BLUE

BROWN

AUX1= 3 FAN SPEEDS
AUX2= ON/OFF CONTROL HIGH ONLY

GREEN/

YELLOW

BROWN

BLUE

GREEN/YELLOW

BLUE

WHITE

FAN

BROWN

BLACK

AUX1

AUX2

FAN

JUNCTION BOX 

2166-191 JUMPER

APPLIANCE

JUNCTION BOX 

BLUE

BROWN

GREEN/

YELLOW

JUNCTION BOX AND 

CONNECTION WIRE SUPPLIED 

BY INSTALLATION 

PROFESSIONAL

FAN HOUSING

ADAPTER FRAME

1/2 in.

(13 mm)

REGISTER

Isolated ON/OFF control wall switch

IPI Plus with auxiliary control

Содержание Heat-Zone-240V Air Duct Kit

Страница 1: ...rs Introduction The HEAT ZONE 240V accessory kit conveys warm air from the heater through air duct s to remote locations in the same room or other rooms of the building See Figures 1 and 2 One or two HEAT ZONE 240V kits can be installed on the heater Preliminary Preparation 1 Contents of kit 6 meters of 152 mm round duct Fan housing assembly Junction box Air register Register adapter frame Heater ...

Страница 2: ...person All relevant codes and regulations laid down by the gas piping authorities municipal building regulations electrical wiring regula tions and the requirements of the AS5601 Gas Instal lation code must be observed 4 Plan the location of the heater and the warm air duct run s MAXIMUM Duct Run 6 M for useful heat output MINIMUM Duct Run NA for runs out from the heater to adjacent room OR down t...

Страница 3: ...52 mm oval duct to the adapter Complete the duct run and attach the oval duct to the fan housing NOTE 152 mm metal oval air duct is NOT provided with this kit but can be purchased from a heating or air conditioning ventilation supplier ROUND and OVAL DUCT Acombination of 152 mm round and 152 mm oval air duct can be used in the duct run Oval duct components must be purchased from a heating or air c...

Страница 4: ...ckage 3 Reference IPI Plus instructions with remote control for fan auxiliary control STUD BROWN HOT BROWN BLUE NEUTRAL BLUE YELLOW GREEN GROUND GROUND SWITCH JUNCTION BOX FAN JUNCTION BOX FAN BLUE BROWN AUX1 3 FAN SPEEDS AUX2 ON OFF CONTROL HIGH ONLY GREEN YELLOW BROWN BLUE GREEN YELLOW BLUE WHITE FAN BROWN BLACK AUX1 AUX2 FAN JUNCTION BOX 2166 191 JUMPER APPLIANCE JUNCTION BOX BLUE BROWN GREEN Y...

Отзывы: