9.0  Fan Wiring with Remote

This appliance may be used with an RC200 or RC300 

remote control.  See Figure 8.

1. Remove cord assembly spades from rheostat and 

sensor switch.

NOTICE:  Fan speed and operation are controlled by the 
remote control.  The sensor switch and rheostat are no 
longer needed.

NOTE:  

USE ZIP TIES TO RESTRAIN 

THE LOOSE WIRES UNDERNEATH 
THE APPLIANCE AND KEEP THEM 
AWAY FROM THE BLOWER WHEEL 
(FAN BLADES). 

NOTE:

 IF ANY OF THE ORIGINAL 

WIRE  AS SUPPLIED WITH THE 
APPLIANCE MUST BE REPLACED, 
IT MUST BE REPLACED WITH TYPE 
105

0

 C RATED WIRE.

NOTE: 

SENSOR SWITCH AND 

RHEOSTAT SPEED CONTROL MUST 
BE REMOVED FROM CIRCUIT IF 
SYSTEM IS CONTROLLED WITH 
RC200/300 REMOTE.

2.  Plug two cord assembly spade connectors together.

3.  Unplug fan cord assembly from standard cord assembly.

4.  Install fuse wire assembly in series between the black 

lead wires of the fan cord and black lead wire on each 
blower.  See Figure 8.

5.  Plug fan cord assembly into AUX300 module.

6.  Plug AUX300 module into the standard cord assembly.

Содержание GFK-210-C

Страница 1: ...ns before starting installation and to follow these instructions carefully during installation to assure maximum benefit from and safe operation of the blower This blower is carefully engineered and m...

Страница 2: ...ly used for the FireBrick inserts See Figure 3 2 Remove appliance from wall 3 Remove access panel by removing screws See Figure 4 Note 35 inch models have two more screws than 30 inch models 4 Screw b...

Страница 3: ...and keep them away from the blower wheel fan blades See Figure 7 Detail A 5 Turn the 110 120 VAC service ON at the circuit breaker 6 0 RECOMMENDED OPERATING PROCE DURES WHEN VARIABLE SPEED CONTROLAND...

Страница 4: ...BLK GRN BLK WHT GRN BLK BLK GRN WHT BLK BLK BLK BLK PLUG INTO 120V EXISTING OUTLET TEMPERATURE SENSOR SWITCH VARIABLE SPEED CONTROL DC REGULATOR RECEPTACLE BLOWER CORD POWER CORD PLUG 120V EXISTING O...

Страница 5: ...and sensor switch NOTICE Fan speed and operation are controlled by the remote control The sensor switch and rheostat are no longer needed NOTE USE ZIP TIES TO RESTRAIN THE LOOSE WIRES UNDERNEATH THE A...

Страница 6: ...12 Connect the fuse wire assembly in series between black wires of blower wire assembly and each blower See Figure 12 5 Route blower plug assembly through back of appliance to right side of appliance...

Страница 7: ...n Wiring Diagram FireBrick Inserts Note if any of the original wire as supplied with the appliance must be replaced it must be replaced with type 105 C rated wire Note use zip ties to restrain the loo...

Отзывы: