Hearth & Home Technologies  •  GFK-210-C Blower System Instructions  2201-938 Rev. F  •  1/13

Figure 1. Carton Contents - GFK-210-C

GFK-210-C Blower System

- Installation and Operating Instructions -

1.0 INTRODUCTION

The GFK-210-C Blower System has been designed to 
circulate room air through the fi replace to enhance heat 
output. The GFK-210-C blower system operates on 120 
VAC, 60 Hz power. This is available through a receptacle 
in the factory installed power cord assembly. The power 
cord is located in the controls compartment of the fi replace. 

An optional variable speed control is available for use  
with the blower system to provide quiet forced air fl ow at 
the desired speeds. A temperature sensor switch, which 
automatically turns the blower ON/OFF, is also provided 
with this kit.  See Figure 2 and Section 8.0.

NOTICE:  The variable speed control and temperature 
sensor switch are not used with some remote control 
systems.

3.0 INSTALLATION PRECAUTIONS

The GFK-210-C Blower Kit is tested and safe when installed 
in accordance with this installation manual. It is your respon-
sibility to read all instructions before starting installation and 
to follow these instructions carefully during installation to 
assure maximum benefi t from, and safe operation of, the 
blower.

This blower is carefully engineered and must be installed 
only as specifi ed. If you modify it or any of its components, 
you may cause a fi re hazard and will void the WARRANTY. 
In addition, such action may void the coverage provided 
by the owner's home insurance.

CAUTION:  All wiring should be done by a qualifi ed electri-
cian and shall be in compliance with local codes and with 
the National Electric Code ANSI/NFPA NO. 70-current (in 
the United States), or with the current CSA C22.1 Canadian 
Electric Code (in Canada).

CAUTION! DO NOT connect 110-120 VAC wiring to the 
gas control valve of the fi replace. 

WARNING!  Risk of Shock! Turn electrical power off at 
the circuit breaker before beginning this installation.

CAUTION! Do not install a damaged blower kit.

VARIABLE SPEED CONTROL

WING

NUT

CONTROL

KNOB

CONTROL

NUT

TEMPERATURE

SENSOR

SWITCH

OPTIONAL

RHEOSTAT/TEMPERATURE 

SENSOR ASSEMBLY

Figure 2. Carton Contents - SRV2206-800

BLOWER CORD

FAN 

BRACKETS

2.0 CHECK CONTENTS OF SHIPPING CARTON

Compare CONTENTS OF CARTON in Figure 1 with the 
actual parts received. If any parts are missing or damaged, 
contact your dealer before starting installation. 

Содержание GFK-210-C

Страница 1: ...ns before starting installation and to follow these instructions carefully during installation to assure maximum benefit from and safe operation of the blower This blower is carefully engineered and m...

Страница 2: ...ly used for the FireBrick inserts See Figure 3 2 Remove appliance from wall 3 Remove access panel by removing screws See Figure 4 Note 35 inch models have two more screws than 30 inch models 4 Screw b...

Страница 3: ...and keep them away from the blower wheel fan blades See Figure 7 Detail A 5 Turn the 110 120 VAC service ON at the circuit breaker 6 0 RECOMMENDED OPERATING PROCE DURES WHEN VARIABLE SPEED CONTROLAND...

Страница 4: ...BLK GRN BLK WHT GRN BLK BLK GRN WHT BLK BLK BLK BLK PLUG INTO 120V EXISTING OUTLET TEMPERATURE SENSOR SWITCH VARIABLE SPEED CONTROL DC REGULATOR RECEPTACLE BLOWER CORD POWER CORD PLUG 120V EXISTING O...

Страница 5: ...and sensor switch NOTICE Fan speed and operation are controlled by the remote control The sensor switch and rheostat are no longer needed NOTE USE ZIP TIES TO RESTRAIN THE LOOSE WIRES UNDERNEATH THE A...

Страница 6: ...12 Connect the fuse wire assembly in series between black wires of blower wire assembly and each blower See Figure 12 5 Route blower plug assembly through back of appliance to right side of appliance...

Страница 7: ...n Wiring Diagram FireBrick Inserts Note if any of the original wire as supplied with the appliance must be replaced it must be replaced with type 105 C rated wire Note use zip ties to restrain the loo...

Отзывы: