Run 2.xlsm
Client:
Job #:
Model:
Tracking #:
Run #:
Technician:
Date:
Elapsed
Time (min)
Gas Meter
(ft
3
)
Sample
Rate (cfm)
Orifice dH
(in H
2
O)
Meter
Temp (°F)
Meter
Vacuum
(in Hg)
Pro. Rate
(%)
Filter (
°
F)
Flue Draft
(in H
2
O)
CO
2
(%)
CO (%)
Flue Gas Data
Particulate Sampling Data
5/13/2021
100
BOX B TEST DATA - ASTM E2780 / ASTM E2515
21-661
SJB
HHT
Expedition 1
2
32
7.003
0.218
1.90
83
-3
100
89
-0.100
12.48
0.42
33
7.221
0.218
1.89
83
-3
100
89
-0.100
12.58
0.39
34
7.438
0.217
1.89
83
-3
99
89
-0.100
12.60
0.40
35
7.654
0.216
1.89
83
-3
99
89
-0.100
12.72
0.44
36
7.870
0.216
1.89
83
-3
101
89
-0.100
12.74
0.50
37
8.087
0.217
1.89
83
-3
99
88
-0.090
12.66
0.54
38
8.305
0.218
1.89
83
-3
100
88
-0.090
12.16
0.56
39
8.521
0.216
1.89
83
-3
99
88
-0.090
11.46
0.33
40
8.738
0.217
1.89
84
-3
102
88
-0.090
10.73
0.16
41
8.954
0.216
1.89
84
-3
99
88
-0.090
10.06
0.10
42
9.170
0.216
1.89
84
-3
98
88
-0.090
9.31
0.10
43
9.388
0.218
1.89
84
-3
99
88
-0.080
8.68
0.13
44
9.605
0.217
1.89
84
-3
99
87
-0.080
8.15
0.09
45
9.822
0.217
1.89
84
-3
99
87
-0.080
7.55
0.11
46
10.038
0.216
1.89
84
-3
98
87
-0.080
7.03
0.10
47
10.255
0.217
1.89
84
-3
98
87
-0.080
6.65
0.12
48
10.472
0.217
1.90
84
-3
98
87
-0.070
6.49
0.11
49
10.691
0.219
1.89
84
-3
99
87
-0.070
6.30
0.14
50
10.907
0.216
1.89
84
-3
98
86
-0.070
6.02
0.18
51
11.124
0.217
1.89
84
-3
98
86
-0.070
5.87
0.20
52
11.341
0.217
1.89
84
-3
98
86
-0.070
5.71
0.23
53
11.558
0.217
1.89
84
-3
98
86
-0.070
5.62
0.26
54
11.776
0.218
1.89
84
-3
98
86
-0.070
5.60
0.29
55
11.994
0.218
1.89
84
-3
98
85
-0.070
5.56
0.31
56
12.212
0.218
1.90
84
-3
98
85
-0.060
5.55
0.32
57
12.429
0.217
1.90
84
-3
98
85
-0.060
5.53
0.34
58
12.646
0.217
1.90
84
-3
98
85
-0.060
5.49
0.38
59
12.863
0.217
1.90
84
-3
98
85
-0.060
5.43
0.40
60
13.081
0.218
1.90
84
-3
98
85
-0.060
5.48
0.40
61
13.300
0.219
1.90
84
-3
99
86
-0.060
5.49
0.39
62
13.518
0.218
1.90
84
-3
98
86
-0.060
5.53
0.40
63
13.736
0.218
1.90
84
-3
98
86
-0.060
5.54
0.41
PFS-TECO
Page 13 of 19
Содержание Expedition-I
Страница 2: ...Project 21 661 Model Expedition I Page 1 This page intentionally left blank ...
Страница 12: ...Project 21 661 Model Expedition I Page 11 Firebox Volume ...
Страница 13: ...Project 21 661 Model Expedition I Page 12 Appliance Front Appliance Left ...
Страница 14: ...Project 21 661 Model Expedition I Page 13 Appliance Right Appliance Rear ...
Страница 18: ...Project 21 661 Model Expedition I Page 17 Sealed Unit ...
Страница 62: ......
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 106: ...25 04 21 7094 802A C Service and Maintenance Log Date of Service Performed By Description of Service ...
Страница 107: ...26 04 21 7094 802A Date of Service Performed By Description of Service ...
Страница 108: ...27 04 21 7094 802A D Accessories ...
Страница 109: ...28 04 21 7094 802A ...
Страница 110: ...29 04 21 7094 802A ...
Страница 133: ...22 7094 803A 04 21 Date of Service Performed By Description of Service ...
Страница 134: ...23 7094 803A 04 21 B Service Parts List ...
Страница 135: ...24 7094 803A 04 21 ...
Страница 136: ...25 7094 803A 04 21 ...
Страница 137: ...26 7094 803A 04 21 ...
Страница 138: ...27 7094 803A 04 21 ...
Страница 146: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 159: ......
Страница 161: ......
Страница 166: ......
Страница 167: ......