Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07
Figure 5.6
1. Top Vent - Horizontal Termination
- (continued)
Three Elbows
H
2
V
2
H
1
V
1
NOTE: There MUST be a 25%
reduction in total H when using
fl
ex vent except when using the
simple up and out installation
(see Figure 5.3).
Note:
Use SL D- Series
components only.
V Minimum
H
1
Maximum
H
1
+ H
2
Maximum
BE-36-C
NG & LP
BE-36-C
NG
BE-36-C
LP
90 Elbow Only
1-1/2 ft.
457 mm
2 ft.
610 mm
2 ft.
610 mm
1/2 ft.
152 mm
1-1/2 ft.
457 mm
4 ft.
1.2 m
3 ft.
914 mm
1-1/2 ft.
457 mm
3 ft.
914 mm
6 ft.
1.8 m
6 ft.
1.8 m
2-1/2 ft.
762 mm
5 ft.
1.5 m
10 ft.
3.0 m
10 ft.
3.0 m
3-1/2 ft.
1.1 m
7 ft.
2.1 m
14 ft.
4.3 m
14 ft.
4.3 m
4-1/2 ft.
1.4 m
15 ft.
4.6 m
14 ft.
4.3 m
14 ft.
4.3 m
H
1
+ H
2
MAX. =14 FT (4.3 m)
V
1
+ V
2
+ H
1
+ H
2
MAX. = 40 FT (12.2 m)