6
Hearth & Home Technologies • GFK-210 Blower System Instructions 2206-938 Rev. H • 7/11
Figure 8. Remove Access Panel
10.0 INSTALLING THE BLOWER (FireBrick Inserts)
1. Remove appliance from wall.
2. Disconnect power by shutting off circuit breaker or
unplugging appliance power cord from its receptacle.
3. Remove access panel from lower rear of the fi replace
insert. See Figure 8.
4. Attach blower to base with two screws. See Figure
9. Connect white and green wires from blower wire
assembly to each blower. See Figure 9. Connect the
fuse wire assembly in series between black wires of
blower wire assembly and each blower. See Figure
10.
5. Insert plug from blower cable assembly into AUX300
receptacle. See Figure 10.
6. Bundle and zip tie loose wires to keep them from con-
tacting blower impeller blades
7. Position the right and left blower assembly into the rear
opening. Take care to ensure that blower housing or its
motor is clear of any adjacent metal. This will ensure
that no undue noise occurs during blower operation.
8. Reinstall access panel.
9. Reconnect power to the insert and install into wall.
Figure 9. Attach Blower to Base
POWER CORD
BLOWER
ACCESS PANEL