Hearth & Home Technologies  •  GFK-210 Blower System Instructions  2206-938 Rev. H  •  7/11

Figure 1

GFK-210 Blower System

- Installation and Operating Instructions -

1.0 INTRODUCTION

The GFK-210 Blower System has been designed to circu-
late room air through the fi replace to enhance heat output. 
The GFK-210 blower system operates on 120 VAC, 60 Hz 
power. This is available through a receptacle in the factory 
installed power cord assembly. The power cord is located 
in the controls compartment of the fi replace. 

A variable speed control is provided with the blower system 
to provide quiet forced air fl ow at the desired speeds. A 
temperature sensor switch, which automatically turns the 
blower ON/OFF, is also provided with this kit.

NOTICE:  The variable speed control and temperature 
sensor switch are not used with some remote control 
systems.

2.0 CHECK CONTENTS OF SHIPPING CARTON

Compare CONTENTS OF CARTON in Figure 1 with the 
actual parts received. If any parts are missing or damaged, 
contact your dealer before starting installation. Do not install 
a damaged blower kit.

3.0 INSTALLATION PRECAUTIONS

The GFK-210 Blower Kit is tested and safe when installed in 
accordance with this installation manual. It is your responsi-
bility to read all instructions before starting installation and to 
follow these instructions carefully during installation to assure 
maximum benefi t from, and safe operation of, the blower.

CONTROL

NUT

060-814

CONTROL

KNOB

100-512

WING

NUT

060-872

TEMPERATURE

SENSOR

SWITCH

046-018A

VARIABLE SPEED CONTROL

2206-800

BLOWER CORD

2206-068

NOTE:  Install the blower using the access panel located on 
the back side of the appliance.

4.0 INSTALLING THE BLOWER (Metal Inserts)

1.  Remove factory-installed blower brackets by removing 

four screws.  Brackets are only used for the FireBrick 
inserts.  See Figure 2.

2.  Remove appliance from wall.

3.  Remove access panel by removing four screws.  See 

Figure 3.  

4.  Screw blowers to access panel on rear of insert with 

four screws.  See Figure 4.

5.  Plug the blower cord into the blower receptacle.  Con-

nect the white, black, and green spade connectors 
from blower cord harness to each blower.  See Figure 
1 and Figure 6.

6.  Bundle and zip tie any wires to keep them from contact-

ing the fan blades.  See Figure 6, Detail A.

7.  Reinstall access panel.

This blower is carefully engineered and must be installed 
only as specifi ed. If you modify it or any of its components, 
you may cause a fi re hazard and will void the WARRANTY. 
In addition, such action may void the coverage provided 
by the owner's home insurance.

CAUTION:  All wiring should be done by a qualifi ed electri-
cian and shall be in compliance with local codes and with 
the National Electric Code ANSI/NFPA NO. 70-current (in 
the United States), or with the current CSA C22.1 Canadian 
Electric Code (in Canada).

CAUTION! DO NOT connect 110-120 VAC wiring to the 
gas control valve of the fi replace. 

WARNING!  Risk of Shock! Turn electrical power off at 
the circuit breaker before beginning this installation.

Figure 2  Remove Blower Brackets

Содержание GFK-210

Страница 1: ...NTROL NUT 060 814 CONTROL KNOB 100 512 WING NUT 060 872 TEMPERATURE SENSOR SWITCH 046 018A VARIABLE SPEED CONTROL 2206 800 BLOWER CORD 2206 068 NOTE Install the blower using the access panel located o...

Страница 2: ...2 Hearth Home Technologies GFK 210 Blower System Instructions 2206 938 Rev H 7 11 Figure 3 Remove Access Cover Figure 4 Attach Blowers to Access Cover...

Страница 3: ...and use the zip ties to restrain them and keep them away from the blower wheel fan blades See Figure 6 Detail A 5 Turn the 110 120 VAC service ON at the circuit breaker 6 0 RECOMMENDED OPERATING PROC...

Страница 4: ...BLK GRN BLK WHT GRN BLK BLK GRN WHT BLK BLK BLK BLK PLUG INTO 120V EXISTING OUTLET TEMPERATURE SENSOR SWITCH VARIABLE SPEED CONTROL DC REGULATOR RECEPTACLE BLOWER CORD POWER CORD PLUG 120V EXISTING OU...

Страница 5: ...nd sensor switch NOTICE Fan speed and operation are controlled by the remote control The sensor switch and rheostat are no longer needed NOTE USE ZIP TIES TO RESTRAIN THE LOOSE WIRES UNDERNEATH THE AP...

Страница 6: ...bly to each blower See Figure 9 Connect the fuse wire assembly in series between black wires of blower wire assembly and each blower See Figure 10 5 Insert plug from blower cable assembly into AUX300...

Страница 7: ...Wiring Diagram FireBrick Inserts Note if any of the original wire as supplied with the appliance must be replaced it must be replaced with type 105 C rated wire BLOWERS GROUND TO VALVE BRACKET GREEN T...

Отзывы: