background image

Page 1

USER’S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS

505,289M
08/2007
Supersedes 02/2007
KAZ # C.6046

HCWB2 & HCWP2 SERIES

IAQ −− HUMIDIFIERS

Litho U.S.A.

E

 2007

Dallas, Texas, USA

Table Of Contents

Introduction

 1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Humidifier Operation

 1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Operating Instructions −− Manual Humidistat

 2

. . . . . . . . 

Operating Instructions −− Universal Humidistat

 2

. . . . . . 

Operating Instructions (Automatic Mode)

3

. . . . . . . . . . 

RETAIN THESE INSTRUCTIONS

FOR FUTURE REFERENCE

Operating Instructions (Manual Mode)

 3

. . . . . . . . . . . . 

Effect of Water Characteristics

 4

. . . . . . . . . . . . . . . . . 

Annual Maintenance

 4

. . . . . . . . . . . . . . . . . . . . . . . . . . 

Annual Shutdown

 4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Dealer Instructions for Preventative Maintenance

 4

Introduction

This manual includes information that will familiarize you
with your humidifier. It also details routine maintenance
required to keep the humidifier working properly.

Electric shock hazard. Can cause injury
or death. Disconnect all electrical power
supplies before servicing. Shut off water
supply before disconnecting or tapping
into any water supply line.

WARNING

!

Risk of Equipment Damage. After humidifier
installation is completed, turn water supply back
on.

CAUTION

!

Humidifier Operation

This humidifier provides the proper relative humidity (RH)
during the heating season. The humidifier is wired to
operate when the indoor blower motor is on during the
heating mode and the indoor RH is below the selected
comfort level. During a call for humidity, water flows into
the EquaFlo

t

 distribution tray, where it is distributed

evenly across the width of the pan. The humidifier pad is
saturated with water. Dry hot air moves through the pad
where evaporation takes place. The humidified air carries
moisture in vapor form throughout the home.

Risk of Equipment Damage. Do not use the saddle
valve to regulate water flow.  The valve is designed
to be completely opened or closed.

CAUTION

!

Содержание HCWB2 Series

Страница 1: ...use injury or death Disconnect all electrical power supplies before servicing Shut off water supply before disconnecting or tapping into any water supply line WARNING Risk of Equipment Damage After humidifier installation is completed turn water supply back on CAUTION Humidifier Operation This humidifier provides the proper relative humidity RH during the heating season The humidifier is wired to ...

Страница 2: ... KNOB MANUAL HUMIDISTAT TABLE 1 Relative Humidity RH Settings Outside Temperature Fahrenheit Recommended RH 40 45 30 40 20 35 10 30 0 25 10 20 20 15 To check the humidifier operation set the humidistat above the click point make sure that the water saddle valve is open and that there is power to the unit The furnace blower motor must be operating for the humidifier to function After the humidifier...

Страница 3: ...Turn the control dial setting to the OFF position Then slowly turn the dial clockwise until you hear the solenoid valve click on Slowly turn the dial counterclockwise until you hear the solenoid valve click off At this point make note of the dial setting 4 Locate your dial setting on table 3 Follow the dial setting to the right until it intersects with the current outdoor temperature This is the R...

Страница 4: ...ING Annual Maintenance For best performance you should replace the humidifier pad at least annually Call your dealer for preventative maintenance and replacement components Annual Shutdown For the summer humidifier shutdown turn the universal humidistat or manual humidistat to the OFF setting HCWB2 12 17 and 17A and HCWP2 18 and 18A and close the damper HCWB2 12 12A 17 and 17A Maintenance NOTE Ann...

Страница 5: ... 8 Position the pad frame assembly so that the tabs are pointing outward Align the drain extension on the pad assembly with the drain spud in the humidifier base Reinsert the humidifier pad assembly in the base Push the pad assembly in at the top until the assembly snaps into place Replace the front cover Turn the damper handle to the WINTER position 9 Remove the drain hose from the bottom of the ...

Страница 6: ...Snap the distribution tray back into place 9 Position the pad frame assembly so that the tabs are pointing outward Align the drain extension on the pad assembly with the drain spud in the humidifier base Reinsert the humidifier pad assembly in the base Push the pad assembly in at the top until the assembly snaps into place 10 Remove the drain hose from the bottom of the humidifier Bend and flex th...

Отзывы: