Page 1
USER’S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS
505,289M
08/2007
Supersedes 02/2007
KAZ # C.6046
HCWB2 & HCWP2 SERIES
IAQ −− HUMIDIFIERS
Litho U.S.A.
E
2007
Dallas, Texas, USA
Table Of Contents
Introduction
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Humidifier Operation
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Instructions −− Manual Humidistat
2
. . . . . . . .
Operating Instructions −− Universal Humidistat
2
. . . . . .
Operating Instructions (Automatic Mode)
3
. . . . . . . . . .
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
Operating Instructions (Manual Mode)
3
. . . . . . . . . . . .
Effect of Water Characteristics
4
. . . . . . . . . . . . . . . . .
Annual Maintenance
4
. . . . . . . . . . . . . . . . . . . . . . . . . .
Annual Shutdown
4
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dealer Instructions for Preventative Maintenance
4
.
Introduction
This manual includes information that will familiarize you
with your humidifier. It also details routine maintenance
required to keep the humidifier working properly.
Electric shock hazard. Can cause injury
or death. Disconnect all electrical power
supplies before servicing. Shut off water
supply before disconnecting or tapping
into any water supply line.
WARNING
!
Risk of Equipment Damage. After humidifier
installation is completed, turn water supply back
on.
CAUTION
!
Humidifier Operation
This humidifier provides the proper relative humidity (RH)
during the heating season. The humidifier is wired to
operate when the indoor blower motor is on during the
heating mode and the indoor RH is below the selected
comfort level. During a call for humidity, water flows into
the EquaFlo
t
distribution tray, where it is distributed
evenly across the width of the pan. The humidifier pad is
saturated with water. Dry hot air moves through the pad
where evaporation takes place. The humidified air carries
moisture in vapor form throughout the home.
Risk of Equipment Damage. Do not use the saddle
valve to regulate water flow. The valve is designed
to be completely opened or closed.
CAUTION
!