2
The HCC16-28 cabinet is designed to house the following
filters:
• HCF16-11
• HCXF16-11
• HCF16-13
• HCF16-16
• HCXF16-16
The HCC20-28 cabinet is designed to house the following
filters:
• HCF20-11
• HCXF20-11
• HCF20-13
• HCF20-16
• HCXF20-16
Healthy Climate box cabinets and filters (box or expandable
media) are purchased separately.
*MERV rating is determined by testing according to
ASHRAE standard 52.2.
Required Tools
The following tools are required to attach the filter cabinet to
the furnace/air handler:
• Electric drill
• 1/4” (6mm) hex head tool
• Tin snips
• Screwdriver
• Rule/tape measure
• Gloves for sharp edge protection
• Foil tape
Rules for Safe Installation
1.
Read this Owners Manual and Rules for Safe Operation
carefully. Failure to follow these rules and instructions
could cause a malfunction of filter or unsatisfactory
service.
2.
Follow a regular service and maintenance schedule for
efficient operation.
3.
Maximum static weight for cabinet - 400 lbs. (181 kg.)
Dimensions
Table 1. Dimensions - inches (mm)
Model#
X
Y
Y1
Z
Z1
HCC14-23
7
(179)
21-1/4
(540)
18-3/4
(476)
23
(584)
18-1/2
(470)
HCC16-28
7
(179)
17-1/4
(438)
14-3/4
(375)
28-1/2
(724)
24
(610)
HCC20-28
7
(179)
21
(533)
18-1/2
(470)
28-1/2
(724)
24
(610)
Dimenions subject to change without notice.
Figure 1. Dimensions
Unpacking
The cabinet must be unpacked and assembled prior to use.
Refer to the following figure to ensure all the necessary
components are included before assembling.
Component List
A 1 - Rear Frame
B 1 - Front Frame
C 1 - Door
D 2 - Side Rail
E 2 - Side Panel
B
C
D
E
A
Figure 2. Unpack