Healthrider HETL09910 Скачать руководство пользователя страница 5

5

24

Congratulations for purchasing the SOFTSTRIDER
S300i™ treadmill by HealthRider

®

. The SOFTSTRIDER

S300i offers an impressive array of features to help
you achieve your fitness goals in the convenience of
your home. From the advanced console to the cush-
ioned walking belt, the SOFTSTRIDER S300i is de-
signed to make each workout more effective and en-
joyable. And when you’re not exercising, the SOFT-
STRIDER S300i can be folded away, taking less than
half the floor space of conventional treadmills.    

For your benefit, read this manual carefully before
using the treadmill. 
If you have additional questions,
please call our our Customer Service Department at
08457-089009. To help us assist you, please note the
product model number and serial number before call-
ing. The model number is HETL09910. The serial
number can be found on a decal attached to the tread-
mill (see the front cover of this manual for the location).

Before reading further, please familiarise yourself with
the parts that are labelled in the drawing below.

BEFORE YOU BEGIN

Handrail

Lock Knob

Console

Book Holder

Hand Weights

Water Bottle Holder*

Chest Pulse Sensor Holder

*Water bottle is not included.

Key/Clip

Circuit

Breaker

On/Off
Switch

Walking Belt

Foot Rail

Cushioned
Walking Platform

Power 

Cord

BACK

RIGHT SIDE

Rear Roller  
Adjustment Bolts

PROBLEM

SOLUTION

a. If the walking belt has shifted to the

left, first remove the key and UNPLUG
THE POWER CORD
. Using the allen
wrench, turn the left rear roller adjustment
bolt clockwise, and the right bolt counter-
clockwise, 1/4 of a turn each. Be careful
not to overtighten the walking belt. Plug in
the power cord, insert the key and run the
treadmill for a few minutes. Repeat until the walking belt is centred.    

b. If the walking belt has shifted to the

right, first remove the key and UNPLUG
THE POWER CORD
. Using the allen
wrench, turn the left rear roller adjustment
bolt counterclockwise, and the right bolt
clockwise, 1/4 of a turn each. Be careful
not to overtighten the walking belt. Plug in
the power cord, insert the key and run the
treadmill for a few minutes. Repeat until the walking belt is centred.

c.  If the walking belt slips when walked

on, first remove the key and UNPLUG
THE POWER CORD
. Using the allen
wrench, turn both rear roller adjustment
bolts clockwise, 1/4 of a turn. When the
walking belt is correctly tightened, you
should be able to lift the edges of the
walking belt 7 to 10 cm (3 to 4 in.) off the
walking platform. Be careful to keep the walking belt centred. Plug in the power
cord, insert the key and run the treadmill for a few minutes. Repeat until the walk-
ing belt is properly tightened.

a. Remove the key from the console and UN-

PLUG THE POWER CORD. Next, remove
the screws from the hood and carefully re-
move the hood. Locate the Reed Switch
(26) and the Magnet (85) on the left side of
the Pulley (28). Turn the Pulley until the
Magnet is aligned with the Reed Switch.
Make sure that the gap between the
Magnet and the Reed Switch is about 
3 mm (1/8 in.). 
If necessary, loosen the
Reed Switch Screw (20) and move the Reed Switch slightly. Retighten the Screw. 

Re-attach the hood, and run the treadmill for a few minutes to check for a correct
speed reading.

a. Due to variations in humidity and temperature, there is a possibility that 

bubbles may form in the walking belt. Although the bubbles will disappear with
time, you may unplug the power cord, carefully insert a needle into the bubbles,
and push the air out of the bubbles.

a

b

c

4. The walking belt is 

off-centre or slips 
when walked on

5. The displays of the

console do not func-
tion properly

6. Bubbles form in the

walking belt 

85

26

20

Top 

View

3 mm

28

a

Содержание HETL09910

Страница 1: ...state Revie Road Beeston Leeds LS11 8JG UK email csuk iconeurope com HOW TO ORDER REPLACEMENT PARTS To order replacement parts contact the ICON Health Fitness Ltd office or write ICON Health Fitness L...

Страница 2: ...7 1 Ground Screw 108 1 Ground Washer 109 1 Ground Nut 110 2 Motor Pivot Bushing 111 2 Endcap Insert 112 1 Motor Pivot Spacer 113 1 Filter 114 1 Splitter 115 1 Power Cord Set 116 1 Audio Wire Nut 117 1...

Страница 3: ...from damage place a mat under the treadmill 4 When choosing a location for the treadmill make sure that the location and position per mit access to a plug 5 Keep the treadmill indoors away from mois t...

Страница 4: ...your body uses easily accessible carbohydrate calories for en ergy Only after the first few minutes does your body begin to use stored fat calories for energy If your goal is to burn fat adjust the s...

Страница 5: ...s centred b If the walking belt has shifted to the right first remove the key and UNPLUG THE POWER CORD Using the allen wrench turn the left rear roller adjustment bolt counterclockwise and the right...

Страница 6: ...8 If an extension cord is needed use only a 3 conductor 1mm2 14 gauge cord that is no longer than 1 5 m 5 ft Important The treadmill is not compatible with GFCI equipped outlets b Make sure that the...

Страница 7: ...e other end of the chest strap to the sensor unit Adjust the length of the chest strap if neces sary The chest pulse sensor should be under your clothing tight against your skin and as high under the...

Страница 8: ...on mode also al lows you to switch the console from miles per hour to kilometres per hour In addition the information mode allows you to turn on and turn off the demo mode To select the information mo...

Страница 9: ...ction of programs that interactively con trol your treadmill to help you achieve your specific ex ercise goals In addition you can play iFIT com audio and video programs directly from the internet To...

Страница 10: ...the walking belt will slow to a stop and the displays will be reset Q Mode indicators These indicators show whether the manual mode a preset program a pulse pro gram or an iFIT com program is selecte...

Страница 11: ...lance Exercises using hand weights should be attempted only by ex perienced users If you have heart problems or if you are over 60 years of age and have been inactive do not use the pulse programs If...

Страница 12: ...ss one of the Stop but tons and adjust the incline of the treadmill to the minimum setting The incline must be at the min imum setting when the treadmill is raised to the storage position or the tread...

Страница 13: ...e Cross Training Indicator in the Time Segment Time display will peri odically flash Whilst the indicator is flashing use the included hand weights for upper body exercise as you walk on the treadmill...

Страница 14: ...nter your age When a pulse program is se lected an age setting will begin to flash in the Calories Watts Pulse display If you have already entered your age simply press the Enter button To enter your...

Страница 15: ...5 6 3 4 62 51 10 11 10 50 49 95 105 3 4 105 16 31 30 28 24 47 83 35 35 3 4 3 4 3 4 38 56 111 92 92 92 92 54 54 85 93 2 87 64 8 8 21 21 113 35 112 110 110 106 106 116 101 EXPLODED DRAWING Model No HETL...

Страница 16: ...92 96 93 91 92 20 94 96 95 94 102 91 72 71 69 68 70 67 65 66 66 65 79 73 63 6 63 6 80 74 74 74 76 75 76 76 76 76 76 81 82 83 103 90 89 84 76 86 88 78 77 97 97 17 48 25 119 115 107 108 109 48 41 114 97...

Отзывы: