background image

-3-

206443-01

Motion

 Least Sensitive 

Most Sensitive

Sensor

Motion

The sensor is less sensitive to motion directly to-
wards it, most sensitive to motion across its field 
of view.

 

Maximum Range 

Maximum  

 

 

 

Coverage Angle

8 ft. 

(2.4m)

70 ft. (21m)

TEST AND ADJUSTMENT

1. 

Turn on the circuit breaker and light switch.

NOTE:  Sensor  has  a  1 

1

/

2

  minute  calibration 

period before it will detect motion. When 
first turned on, wait 1 

1

/

2

 minutes.

2.  Turn the RANGE control to the mid position and 

the ON-TIME control to the TEST position.

10 5 1 TEST

ON-TIME

Bottom of Sensor

 

Avoid aiming the control at:

•  Objects that change temperature rapidly, such 

as 

heating vents and air conditioners. These 

heat sources could cause false triggering.

•  Areas  where 

pets or traffic  may  trigger  the 

control.

•  

Nearby large, light-colored objects reflecting 
light may trigger the shut-off feature. Do not point 
other lights at the sensor.

180°

3.  Loosen  the  clamp  screw 

in the sensor ball joint and 
gently rotate the sensor.

4.  Walk  through  the  cover-

age  area  noting  where 
you  are  when  the  lights 
turn on (also, the LED will 
flash  several  times  when 
motion is detected). Move 
the sensor head up, down, 
or sideways to change the 
coverage area. 

Keep the 

sensor at least 1" (2.5 cm) 
away from the lamps.

5.  Adjust  the  RANGE  as 

needed.  RANGE  set  too 
high  may  increase  false 
triggering.

6. 

Secure the sensor head 
by tightening the clamp screw.
 Do not over-
tighten the screw.

7.  Set the amount of TIME you want the lights to stay 

on after motion is detected (1, 5, or 10 minutes).

 WARNING: Risk of fire. Do not aim the lamps 

at a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Range . . . . . . . . . . . . . .  Up to 70 ft. (21 m) [varies with 

surrounding temperature].

Sensing Angle . . . . . . . .  Up to 180°
Electrical Load . . . . . . . .  Up to 500 Watt (4.2A) Maximum 

Incandescent [Up to 250 Watt 
maximum each lamp holder.]

Power Requirements . . .  120 VAC, 60 Hz
Operating Modes . . . . . .  TEST,  AUTO  and  MANUAL 

MODE

Time Delay  . . . . . . . . . .  1, 5, 10 minutes
Range . . . . . . . . . . . . . .  Adjustable 
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without 
incurring any obligation to incorporate new features in 
products previously sold.

RANGE

MIN 

MAX

Clamp 
Screw

Ball 
Joint

Aim Sensor 

Down for Short 

Coverage

Aim Sensor 

Higher for Long 

Coverage

Отзывы: