Opening the 2600KL Scale 

 

1. From its upright folded position, gently lower the scale onto its feet. Use the scale 
handles, located on the front of the platform (see Figure 10). 

2. Loosen all four of the handrail locking pin assemblies by turning the locking pins 
counterclockwise (see Figure 8).   

Note:

 The assemblies are spring loaded, and will pop out when completely loosened. 

3. Grasp the center handrail near the display assembly, and lift the handrail to an upright 
position.   

4. Lock the center handrail in the upright position by tightening the two upper handrail 
locking pin assemblies.  In addition, to avoid damage to the pin assemblies, tighten the two 
lower locking pin assemblies as well. 

 

 

Preparing the 2500KL / 2600KL Scale for Use 

 

1. Remove the protective plastic film covering the display (the film says “FACTORY 
CALIBRATED”). 

2. Place batteries into the battery holder (see “Replacing / Inserting Batteries” information 
below). 

3. Connect the AC adapter into the adaptor jack on the display assembly. 

4. Plug the scale’s AC adapter into the power source. 

5. Ensure all objects are removed from the scale’s platform.  Press the 

ON/OFF

 button to 

turn the scale on. The display will show “Start”, then “0.0LB” or “0.0KG”.   

6. Press the 

UNIT

 button to select the weight mode (lb or kg).  

Note:

 These scales will always default to the settings and units last used (lb or kg). 

7. When you disconnect the scale’s AC adapter from the power source, the scale will switch 
to battery power if batteries are installed.  

Note:

 If the setup procedure failed, refer to the troubleshooting instructions. If the problem is 

not corrected, refer to qualified service personnel.  

 

Содержание 2500KL

Страница 1: ...Model 2500KL 2600KL Digital Patient Wheelchair Scales User Instructions P N UM2500KL 2600KL Rev 2 031913 1...

Страница 2: ...NTENTS Caution and Warning 3 Specifications for These Scales 4 Certifications Connectivity Disposal 5 Assembly Instructions 2500KL Scale 6 Assembly Instructions 2600KL Scale 14 Setup Batteries 19 Quic...

Страница 3: ...contact with liquids excessive temperature or excessive humidity Operating these scales at voltages and frequencies other than specified can damage the equipment and will void the warranty Do not tra...

Страница 4: ...ty the 2500KL Scale has 2 built in wheels along with the 2600KL Scale with 4 built in wheels Each scale can be powered using an AC adapter included or by 6 AA batteries not included 2500KL 2600KL Spec...

Страница 5: ...Equipment 2500KL 2600KL Scale Connectivity Information To enable reliable transmission of weight height and Body Mass Index BMI data these scales are designed to connect to a computer monitor or othe...

Страница 6: ...remove each assembly from the carton and unwrap the packing materials Set the carton aside for storage To avoid damaging the scale parts when unpacking do not use a box cutter knife scissors or any s...

Страница 7: ...he load cell cable protruding from the bottom of the platform and feed it through the protective metal shield Plug the cable s load cell connector into the load cell port see Figure 4 9 Pull the exces...

Страница 8: ...4 Phillips pan head 5 x 3 8 screws see Figure 1 16 Attach the adapter holder to the left side of the handrail using the 2 8 x sheet metal screws see Figure 1 17 Connect the AC adapter to the power po...

Страница 9: ...f the platform Use the appropriate mounting holes see Figure 2 6 Loosen the screws holding each ramp holder to the platform 7 Remove the ramp from the ramp holders Remove the ramp holders by pulling o...

Страница 10: ...2500KL ASSEMBLY INSTRUCTIONS CONTINUED Figure 1 Figure 2 10...

Страница 11: ...2500KL ASSEMBLY INSTRUCTIONS CONTINUED 11 Handrail Mounting Holes Left Right Guardrail Figure 3 Load Cell Port Shield Figure 4...

Страница 12: ...2500KL ASSEMBLY INSTRUCTIONS CONTINUED Figure 5 Figure 6 12...

Страница 13: ...2500KL ASSEMBLY INSTRUCTIONS CONTINUED Figure 7 13...

Страница 14: ...ng any components carefully remove each assembly from the carton and unwrap the packing materials Set the carton aside for storage To avoid damaging the scale parts when unpacking do not use a box cut...

Страница 15: ...cell cable connector to the load cell port located on the back of the display assembly The port is labeled LOAD CELL see Figure 7 Note Do not attach the AC adapter power cord into the back of the dis...

Страница 16: ...of the platform Use the appropriate mounting holes see Figure 10 6 Loosen the screws holding each ramp holder to the platform 7 Remove the ramp from the ramp holders Remove the ramp holders by pulling...

Страница 17: ...2600KL ASSEMBLY INSTRUCTIONS CONTINUED Figure 8 Figure 9 17...

Страница 18: ...2600KL ASSEMBLY INSTRUCTIONS CONTINUED Figure 10 Load Cell Port 18...

Страница 19: ...2500KL 2600KL Scale for Use 1 Remove the protective plastic film covering the display the film says FACTORY CALIBRATED 2 Place batteries into the battery holder see Replacing Inserting Batteries info...

Страница 20: ...he batteries with new units Health o meter recommends using an alkaline or lithium battery rated for 130 F 54 C operation Do not use Zinc Carbon batteries 4 Re attach the battery cover to the display...

Страница 21: ...ta to calculate patient s Body Mass Index BMI RECALL Recalls the previous weight TARE PRETARE TARE Tares out weight of an object on the platform PRETARE Prompts entry of a tare value that will be dedu...

Страница 22: ...ight equal to the weight of the wheelchair 6 Place the patient and wheelchair on the scale The scale will automatically deduct the tare weight of the wheelchair from the gross weight of the patient an...

Страница 23: ...cale will begin to display weight information and will lock on the patient s weight when the stable weight of the patient is determined Depending on the movement of the patient on the scale it may tak...

Страница 24: ...t information and will lock on the patient s weight when the stable weight of the patient is determined Depending on the movement of the patient on the scale it may take several seconds for the scale...

Страница 25: ...arance of the total scale for any obvious damage wear and tear 2 Inspect the AC adapter for cord cracking or fraying or for broken bent prongs Cleaning Proper care and cleaning is essential to ensure...

Страница 26: ...count number 2 Press the ENTER button CAL 3 Make sure there is nothing on the scale then press the ENTER button again Clear followed by 0400 0LB 4 Use the and buttons to set the calibration weight to...

Страница 27: ...ot placed on a level floor 3 Place the scale on a level floor and begin weighing process again 4 Scale is out of calibration 4 Check weight with known weight value 5 Improper Tare 5 Place the item to...

Страница 28: ...e the terms and conditions of this warranty What is Excluded Your warranty does not cover normal wear of parts or damage resulting from any of the following negligent use or misuse of the product use...

Отзывы: