Health O Meter 2101KL Скачать руководство пользователя страница 5

CERTIFICATIONS / CONNECTIVITY / DISPOSAL 

 
 

Certification Descriptions 

 

 
 

2101KL Scale Connectivity Information 

 

To enable reliable transmission of weight, height, and Body Mass Index (BMI) data, this scale is 
designed to connect to a computer, monitor, or other electronic device via a built-in USB port. 
This connectivity helps minimize a source of potential medical errors caused by incorrectly 
copying and then recording patient data.   

 

This scale is EMR-EHR compatible. For more information regarding how to connect this scale to 
other electronic devices, please contact Health o meter® Professional Scales Technical 
Support, available during normal business hours at 1-800-638-3722. 

 

2101KL Scale Disposal 

 

 

 

This Health o meter® Professional scale must be disposed of properly as electronic waste.  
Follow the national, regional or local regulations which apply to you for disposal of electronic 
waste or batteries.  Do not dispose of this device in the domestic waste stream.  

 

 

 

 

 

Pelstar, LLC has been officially certified as the manufacturer 
of Health o meter® Professional medical devices. The Pelstar, 
LLC quality assurance system covers the development, 
production, sales and service of medical scales and 
measuring systems. 

 

 

This product is tested to and meets the requirements of: 

1. UL60601-1 First Edition: Safety for Medical Electrical 
Equipment 

2. CSA C22.2 No. 601-1 M90: Medical Electrical Equipment 

Содержание 2101KL

Страница 1: ...1 Model 2101KL Digital Handrail Scale User Instructions P N UM2101KL Rev20170306...

Страница 2: ...s Scale 4 Certifications Connectivity Disposal 5 Assembly Instructions 2101KL Scale 6 Setup Batteries 12 Operating Instructions 13 Maintenance 17 Calibration 18 Troubleshooting 19 Warranty 20 Note Thi...

Страница 3: ...come in contact with liquids excessive temperature or excessive humidity Operating this scale at voltages and frequencies other than specified can damage the equipment and will void the warranty Do no...

Страница 4: ...for patient comfort and safety It also has a 180 swivel display head for privacy and easy operator reading from either side of the scale This scale has 2 wheels built in for easy mobility This scale...

Страница 5: ...cales Technical Support available during normal business hours at 1 800 638 3722 2101KL Scale Disposal This Health o meter Professional scale must be disposed of properly as electronic waste Follow th...

Страница 6: ...h assembly from the carton and unwrap the packing materials Set the carton aside for storage To avoid damaging the scale parts when unpacking do not use a box cutter knife scissors or any sharp object...

Страница 7: ...and lightly tighten see Figure 2 8 Pull forward on the side handrails to tip the scale and gently place it face down on the floor 9 Grasp the load cell cable protruding from the bottom of the platfor...

Страница 8: ...to the center handrail using 2 8 x sheet metal screws D Use Phillips head screwdriver to tighten the screws see Figures 1 2 18 Connect the AC adapter to the power port in the display Do not plug the s...

Страница 9: ...9 2101KL ASSEMBLY INSTRUCTIONS CONTINUED Figure 1 Figure 2...

Страница 10: ...10 2101KL ASSEMBLY INSTRUCTIONS CONTINUED Figure 3 Figure 4 Load cell cable Scale platform Holes arrays Center handrail...

Страница 11: ...11 2101KL ASSEMBLY INSTRUCTIONS CONTINUED Figure 5 Figure 6 Load cell port Cable connector Protective metal shield...

Страница 12: ...ery operation see Battery Installation below Battery Installation 1 If connected unplug the AC adapter from the power source 2 Use a Phillips head screwdriver to remove the battery cover on the side o...

Страница 13: ...to calculate patient s Body Mass Index BMI RECALL Recalls the previous weight TARE PRETARE TARE Tares out weight of an object on the platform PRETARE Prompts entry of a tare value that will be deducte...

Страница 14: ...KG and LB Weighing a Patient 1 Make sure there is nothing on the weighing platform 2 Press the ON OFF button to turn on the scale 3 Wait until the 0 0 LB or 0 0 KG appears on the display 4 Ask the pat...

Страница 15: ...splay 3 Place the object to be tared on the scale The display will show the object s weight 4 Press the TARE button The scale will zero out and the word TARE will appear at the bottom center of the di...

Страница 16: ...lue for the parent s weight 5 Ask the parent to step off of the scale Once the parent is off of the scale the display will show a negative weight equal to the parent s weight 6 Ask the parent to step...

Страница 17: ...pect the AC adapter for cord cracking or fraying or for broken bent prongs Note This scale is an extremely sensitive weighing device If the auto off function is disabled battery power will be consumed...

Страница 18: ...pear next to U followed by 4 5 characters U XX followed by a 4 5 digit idle scale count number 2 Press the ENTER button CAL 3 Make sure there is nothing on the scale then press the ENTER button again...

Страница 19: ...not placed on a level floor 3 Place the scale on a level floor and begin weighing process again 4 Scale is out of calibration 4 Check weight with known weight value 5 Improper Tare 5 Place the item to...

Страница 20: ...or current use contrary to the operating instructions abuse including tampering damage in transit or unauthorized repair or alternations Further the warranty does not cover natural disasters such as f...