- 17 -
The LCD Screen Partially
Displays
The connection between the
Circuit Board and the LCD
Screen Membrane is
Misaligned. If this is the
problem you might be able to
see that the LCD Screen is on
a slight angle and NOT inline
or parallel with the Computer
Case.
Open the Computer Case,
remove the Circuit Board
Screws, gently remove the
Circuit Board, reassemble the
LCD Screen and/or the
Membrane taking care not to
bump or knock the Membrane
out of alignment before the
Circuit Board Screws are tight.
Do NOT over tighten the
screws in the circuit board.
The Computer is faulty.
Replace the Computer by
contacting your dealer.
No Hand Pulse Signal or
incorrect Hand Pulse Signal
The Computer is NOT
receiving a pulse Signal.
Check that the Hand Pulse
Plugs are FIRMLY inserted
into the sockets.
The Computer is receiving a
faint of Intermittent Pulse
Signal.
(1)The Hand Pulse Sensors
will NOT operate correctly if
your skin is extremely dry
moisten your hands with a little
water and try again
(2)The Hand Pulse Sensors
are designed to be held firmly.
If you move your hands while
exercising then the Computer
may receive an Intermittent
Pulse Signal. Avoid moving
your hands while exercising
and hold the Hand Pulse
Sensors firmly while
exercising. If you do move
your hands while exercising
give the Computer a few
seconds to resample and
display your correct Pulse
Heart Rate.
(3)Clean the Hand Pulse
Sensors to ensure a good
contact between your body
and the Pulse Sensors.
(4)Remove the Hand Pulse
Sensors in order to check that
the Spade Terminals are
correctly attached.
*After completing all of the
above checks, If the problem
still exists then please contact
your dealer.
The Computer is faulty.
Replace the Computer by
contacting your dealer.
Содержание PhysioStep HXT