Specifications
-
Compatible with ALL vehicles using a 12V battery
-
Solid-state, fuseless design
-
Reverse polarity and transient protection
-
Standby current at 12V: less than 1 mA
-
Operating temp: -40°C to +80°C (-40°F to +176°F)
-
Unit size: 59 x 35 x 17 mm (2.3 x 1.4 x 0.7 inches)
-
Waterproof (IP68)
4.
Included items
-
TB module with main wiring
-
for TB-U01:
one set of quick connect terminals
-
for TB-U02:
two sets of quick connect terminals
-
1pc 15cm / 5” control wire with bullet connector
-
1pc wire tap connector, gel-filled
-
2pcs HealTech sticker sets
5.
Operation modes
The ThunderBox can operate in three different modes. Depending of the connection of the
WHITE control wire
the following modes can be acquired:
› Automatic mode:
The White control wire is left disconnected/unused.
When the engine is started and runs evenly, the TB switches the power outputs ON.
When the engine is stopped, after a few seconds the TB switches the outputs OFF.
› Ignition-controlled mode:
The White control wire is connected to an ignition key sw12V power source, e.g.
to the hot wire of the number plate light or running light.
The TB will switch the outputs ON/OFF (with a few seconds delay) following the ignition
key switch position. This mode is recommended if you intend to connect a battery charger
without disconnecting/removing the battery from the bike.
› Stay-off mode:
The White control wire is connected to the TB’s Black wire terminal block.
The TB will keep the outputs OFF. If you normally use the Automatic mode, connect the
White wire to the Black (you may do so via a switch), before connecting a battery charger.
6.
Power management
› Delayed ON
When the power-up conditions are met, the TB delays power output for about two seconds.
Indicated with a rapidly flashing green light.
› Delayed OFF
When the ignition key is turned off, the TB turns the outputs OFF after about five seconds.
Indicated with the green light blinking slowly.
› Overload management
The intelligent overload management allows inductive loads such as halogen bulbs to be
lit/turned on. The TB allows overloading its circuit(s) for 200 milliseconds.
If the overload (greater than 16A) duration exceeds 200 milliseconds, the TB will turn the
power output OFF.