background image

Page 

15

  of 

24

 

 

SSD data and power connector will stick out a bit of the HDD rack for SATA cable 
easy access. 

 

If you are using HDPLEX 400W NanoATX Combo power supply, we recommend 
using 50mm length copper stud 

G

 to install the HDD rack. You could install two 

SSD and one 3.5

 HDD on top of 400W DC-ATX converter and two SSD on top of 

400W AC-DC adapter with HDD rack reversed. 
 

 

If you have a long video card or is using H5.TODD, you could double stack the 
second HDD rack with 3.5HDD on top of the first rack using 10mm copper stud. 

 

 

Содержание 2nd Gen H5 Fanless

Страница 1: ...Page 1 of 24 2nd Gen H5 Fanless HTPC Chassis Installation Guide V 2 0 ...

Страница 2: ...ü fterloses Gehä use gekauft haben egal wo kö nnen eine 30USD Rü ckerstattung Belohnung erhalten Es ist sehr einfach diese Rü ckerstattung Belohnung zu bekommen 2 oder 3 Bilder mit etwas Text Kritik Vorschlä gen den Sie in einem beliebigen ö ffentlichen Forum Facebook Blog posten reicht dafü r aus Senden Sie den Link an reward hdplex com und erfreuen sich an einer unmittelbaren Paypal Rü ckerstatt...

Страница 3: ...5 Accessories Multipurpose HDD Rack x 2 ATX SFX FlexPower Supply Rack x 1 Internal USB 3 1 Type C Cable x1 Internal AC Extension Cord x 1 HEX Screw Driver and Allen Wrench DC Socket Adapter Plate x 1 AC Socket Adapter Plate x 1 PCI Cover Bracket x 4 Low Profile x 1 Installation Screw Kit Cable Organizer Aluminum Power Button w Cable x 1 Front Handle x 2 Installation Screw List A M3 6mm Round Head ...

Страница 4: ...5 Flat Head Screw Black 18pcs For SSD mounting AC IEC installation E 7mm Hexagonal Copper Stud for Motherboard Installation 12pcs F 6 32 Thread 6mm Screw Silver 8pcs For 3 5 HDD Installation G Hexagonal Copper Stud for HDD Rack 10mm 4pcs 30mm 8pcs 50mm 8pcs J M3 Self Tightening Nut Silver 20pcs K M3 Round Head 8mm Screw 8pcs ...

Страница 5: ...m plate back side using 4pcs C Install Hexagonal Copper Stud 7mm E to the bottom plate matching your motherboard installation position Install J to the back side of the H5 bottom plate lock the copper stud M3 exposed thread Install the aluminum power button on the right panel using lock ring from the ...

Страница 6: ...2pcs C When installed correctly the mounting ear should face forward with power button above the heatpipe groove H5 CPU Heatsink System Installation CPU Heatsink Installation Kit List H 1 M3 4mm Flat Head Silver 8pcs H 2 M3 10mm CUP Head HEX Screw Silver 8pcs H 3 M 3 35mm Round Head Screw Silver 4pcs H 4 M3 14mm Flat Head Screw Black 16pcs H 5 Intel and AMD CPU Bottom Rack 4pcs H 6 Intel CPU LGA11...

Страница 7: ...ction of part H 8 is correct Install 4pcs H 3 into the H 8 holder Apply a thin layer of thermal paste to the copper base plate Warning Do not over apply thermal paste as it will decrease heat transfer efficiency Put the Intel CPU Bottom Rack H 6 on the back side of the motherboard Intel CPU socket LGA1151 1155 1150 or use 4pcs white double tape to paste the four bottom holder H 7 to the back of th...

Страница 8: ... onto the motherboard Please make sure heatpipe slot direction is vertical to the side panel Tighten the four H 3 screws in even fashion Do NOT over tighten the H 3 screw or apply too much torque Avoid put too much pressure on the CPU top plate For the latest AM4 Ryzen socket see below for correct rack installation position ...

Страница 9: ...Install the copper heatsink block using 4 H 3 Apply thermal paste to the heatpipe groove on both side panels using the dumbbell shaped tool Apply a thin layer of thermal paste to the copper plate groove using the dumbbell tool Warning Do not over apply thermal paste as it will decrease heat transfer efficiency ...

Страница 10: ...Page 10 of 24 Install heatpipe 1 and 2 Install heatpipe 3 and 4 ...

Страница 11: ...6 Install heatpipe 7 and 8 Tighten the H 9 to the side panel using H 4 which goes through the hole on the side panel from outside of the H5 chassis H 9 is NOT square shape and needs to be in the correct direction to match the mounting hole ...

Страница 12: ...oove on the aluminum top plate and install the aluminum top plate using 8pcs H 2 Power Supply Installation HDPLEX 400W AC DC 400W DC ATX NanoATX Combo HDPLEX 400W AC DC is back mounted on the H5 bottom plate via the M2 5 screws come with the HDPLEX 400W AC DC package HDPLEX 400W AC DC optional mounting ears are NOT used for H5 installation ...

Страница 13: ...3 holes in the center on the back of the 400W AC DC adapter are not used for H5 mounting HDPLEX 400W DC ATX is front mounted using M3 screws One 24PIN extension cable is included in the H5 package For ITX motherboard the 400W DC ATX can be installed on the same side as 400W AC DC adapter and in front the ITX motherboard ...

Страница 14: ...board attach the universal rack to the power supply using 2pcs A first Plug the AC extension cord to the power supply and install them to the PSU rack mounting hole on the top left of the H5 bottom plate using 2pcs D Hard Drive Installation Install 3 5 HDD using F and 2 5 HDD SSD using D to the hard drive rack ...

Страница 15: ...ly we recommend using 50mm length copper stud G to install the HDD rack You could install two SSD and one 3 5 HDD on top of 400W DC ATX converter and two SSD on top of 400W AC DC adapter with HDD rack reversed If you have a long video card or is using H5 TODD you could double stack the second HDD rack with 3 5HDD on top of the first rack using 10mm copper stud ...

Страница 16: ... stud and J lock the copper stud exposed M3 thread on the outside of the HDPLEX bottom plate Backplate and PCI E Card Installation If you are using the H5 backplate with dual full height horizontal PCI E slot and a low profile expansion card on the first slot without riser please install this card on the motherboard before you install this H5 back plate ...

Страница 17: ...f the backplate and AC C14 connector using 2pcs D If you are using 7 4 5 0mm self lock connector please install the DC Adapter Plate using 2pcs A to the AC adapter plate HDPLEX ATX Modular Bridge Input Board This product is included with 500W ATX linear PSU and could also be purchased separately Install 4pcs 4mm copper post comes with the ATX Modular board onto the H5 back plate Install the ATX mo...

Страница 18: ...hed motherboard I O shield plate to the H5 back plate and install the back plate using 4pcs B to two side panel and two pcs C to the bottom plate Lock the half height card using 1pcs A on the M3 thread hole If you are using H5 backplate with seven low profile slots please install the power adapter plate IEC C14 AC input and PCI cover bracket first Lock the PCI cover brackets and power adapter plat...

Страница 19: ...fter everything is in place you can lock the top of low profile PCI E expansion card using A GPU Heatsink System Installation First please connect the PCIEx16 riser card to your video card and turn on PC to test If test fine and PCIEx16 card is showing the correct PCIE version 3 0 and speed x16 under benchmark or load test disconnect everything HDPLEX GPU heatsink system parts list Eight 6mm OD Co...

Страница 20: ... 3 M2 5 7mm screws w spring 4pcs Uninstall the original heatsink from the video card and install the copper plate using 4pcs V 3 Please make sure the copper base slot facing the correct direction Apply a very thin layer of thermal paste between copper base plate and GPU top plate ...

Страница 21: ...o the H5 back plate Slide the dual bracket tip inside and using 1pcs A firmly attach the video card bracket to H5 back plate Apply thin layer of thermal paste to the side panel groove and install eight heatpipes following the below pattern ...

Страница 22: ...uminum plate on the side panel using V 1 first and aluminum top cover using 8pcs V 2 Faceplate Installation If you don t need front handle just mount the faceplate using 4 HEX Socket Cap Head M5 12mm B to the two H5 side heatsink panel ...

Страница 23: ...from the back Use M5 HEX key Allen wrench to tighten it Test PC thoroughly and make sure heatsink system functions well Close the H5 top plate using 6pcs C If the distance between two side panels is too tight for the top plate to fit in please first loosen the screws in the red circle below then insert the top plate half way tighten the screws for the heatsink system aluminum top plate insert the ...

Страница 24: ...nless chassis please visit our community at https www hdplex com forum Copyright 2019 2020 HDPLEX LTD All rights reserved All trademarks are the property of their respective owners Reproduction in whole or in part without written permission is prohibited ...

Отзывы: