background image

User Manual 

SB-DN-SEC250K 

 

 

Advanced Security Controller – User Manual                                                                                                     

2

 

1.3 Device Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Safety Instructions 

 

The screw down strength should not exceed 0.4Nm.   

 

Do not make wrong connection on Bus interface, it will damage the Bus interface of 

this module. 

 

Never let liquids get into this module, it will damage this device. 

 

Do not get AC220V voltage into Bus wire, it will damage all devices in the system. 

 

Ensure good ventilation. 

 

Avoid contact with liquids and corrosive gases.

 

 

 

 

a . LED Indicator 

b . Programming button 

c . HDL Buspro 

 

 

Содержание Buspro HDL-MSM.431

Страница 1: ...hdlautomation com User Manual Manual describes the snapshots taken in the previous version of the module and using older HBST program In HBST2 the graphic appearance is slightly different but the functions remain the same Usable for also HDL MSM 431 ...

Страница 2: ...ID 6 5 1 2 Date Setting for Timer 6 5 1 3 History Log 6 5 2 Basic Setting 7 5 3 Auto Dial Out 10 5 4 Arming Settings 12 5 5 Alarm Commands 13 5 6 Vacation Settings 13 5 7 Bypass Settings 14 5 7 1 Alarm Bypass 14 5 7 2 Arming Settings 14 5 8 Advanced Security 15 5 9 Arm Flow 16 5 9 1 Vacation Away Mode 17 5 9 2 Day Night Night_Guest Mode 18 5 10 Alarm Flow 19 5 10 1General flow 19 5 10 2 Vacation A...

Страница 3: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 6 2 Sensor Settings 28 6 3 Vacation Settings 30 7 Note 36 ...

Страница 4: ...g and alarm Up to 32 sensors can be used to detect in each area Normally use DLP panel TouchLife and iLife to arm and diasarm the system 1 1 2 Mounting DB Box installation 1 2 Functionalities Description Manage 8 independent areas Multiple security modes Vacation Away Night Day etc Multiple alarm modes Panic Gas Fire Temperature Emergency etc Multi Level security protection Arm and alarm log Sends...

Страница 5: ... Do not make wrong connection on Bus interface it will damage the Bus interface of this module Never let liquids get into this module it will damage this device Do not get AC220V voltage into Bus wire it will damage all devices in the system Ensure good ventilation Avoid contact with liquids and corrosive gases a LED Indicator b Programming button c HDL Buspro ...

Страница 6: ...00s about 2hours 50mins Program number Max 50 Signal type DMX512 1990 HMI 128x64 raster graphic LCD 6 soft touch buttons Environmental Conditions Working temperature 0 45 Working relative humidity Up to 90 Storage temperature 20 60 Storage relative humidity Up to 93 Approved CE RoHS Production Information Dimensions 72 90 66 mm Housing material Nylon PC Installation 35mm DIN rail installation Prot...

Страница 7: ... Manual 4 4 Installation 4 1 Wiring 4 2 System Connection Security module should work in conjunction with other products to make up a system Security Module LCD Panel Relay Module Dimmer Module Dry Contact Z Audio Module SMS Module PIR Sensor Air Quality Sensor ...

Страница 8: ...ct the Modify address when device button is pressed it will show a window like this d click the Indicate initial address then it will show the ID of this device If you want to modify the address fill in the new address and click the Modify initial address Click the Add button the device will be add in ON line devices list Method Two a open the HDL BUS Pro Setup tool b click the search button it wi...

Страница 9: ...t Date and Time manually or read it from PC It broadcasts the time to system by default It supports Daylight Saving Time function some countries like EU countries Australia need to use it then can set the start time and end time here according to different places 5 1 3 History Log Ready history Enter the start time and end time so you can view arm disarm and alarm log during this time period Clear...

Страница 10: ...in When the delay time elapses it will restart into the monitoring state if there are more triggers it will trigger the buzzer siren alarm and so on then realize that monitor and alarm circularly Entry Delay 10 180S The delay time for entering the door Under arming it will trigger the ENTER BUZZER ON targets when entry If disarmed during the delay time the ENTER BUZZER OFF targets will be triggere...

Страница 11: ...han the exit delay then it will countdown the Entry Delay time and trigger the corresponding targets ENTER BUZZER ON The actions when entering the door the targets can be a voice hint from music player or a buzzer on controlled by relay module ENTER BUZZER OFF The setting targets will be triggered if disarm is not happened after the Entry Delay time elapses Suggest to shutdown the same controlled ...

Страница 12: ...udio to play the 21st voice hint the voice hint can be it s raining outside do not forget to take the umbrella with you It will trigger the Beep Tone targets firstly later trigger the EXIT BUZZER ON targets when leaving the house EXIT BUZZER ON The actions when leaving the house the targets can be a voice hint from music player or a buzzer on controlled by relay module EXIT BUZZER 5S LEFT The acti...

Страница 13: ...When disarmed it will trigger these OFF targets FIRE SIREN ON These targets will be triggered if there is a fire alarm they can be a alarm speaker and so on FIRE SIREN OFF When disarmed it will trigger the FIRE SIREN OFF targets Recommendation the above mentioned OFF and ON targets should be the same otherwise there will be some of them can not be turned off after you disarm the system 5 3 Auto Di...

Страница 14: ... alarm modes can be set All these 13 kinds of alarm modes are independent it will trigger the GPRS module to send out messages during different time period for each mode Message No Please enable the message number each alarm mode can send out up to 4 kinds of alarm information the alarm information can be set in the GPRS module Time Period During the alarm time period if there is an alarm occurrin...

Страница 15: ...he targets after the Exit Delay time Arming Modes There are 6 arming modes can be set respectively they are VACATION ARM AWAYARM NIGHT ARM NIGHT_G ARM DAY ARM DISARM ARM Each mode can control up to 32 targets Auto arming and disarming 1 Auto Arming If the conditions are met enable auto arming and within the set time then it will automatically work under the arming mode 2 Auto Disarming If the cond...

Страница 16: ...tely Each mode can control up to 32 targets 5 6 Vacation Settings It s mainly for setting some targets in the vacation mode so it could simulate scenarios such as turn on off lights by timer function in the house to give the illegal invaders a warning that somebody is at home Can set the control targets in ON and OFF windows independently When reach the start time point it will trigger the ON wind...

Страница 17: ...le s ID in the sensor also when the status of it has changed under arming mode it will send out commands to the security module then the security module will trigger corresponding targets to protect the system for details of these settings please check the 6 Application below 5 7 2 Arming Settings Authorize some user interfaces to arm and disarm the system e g DLP TouchLife iLife iRidium and so on...

Страница 18: ... time when panic alarm 24 Hours Active mode it will trigger these 9th targets which can be set in the right side window The time unit is second 10th line of Defence Activate after Alarm M Set the delay time for the 10th line defence after the delay time when normal alarm it will trigger these 10th targets which can be set in the right side window The time unit is minute Can select this 10th line d...

Страница 19: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 16 5 9Arm Flow ...

Страница 20: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 17 5 9 1 Vacation Away Mode ...

Страница 21: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 18 5 9 2 Day Night Night_Guest Mode ...

Страница 22: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 19 5 10Alarm Flow 5 10 1General flow ...

Страница 23: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 20 5 10 2 Vacation Away Night for Guest Day Mode ...

Страница 24: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 21 5 10 3Night Mode ...

Страница 25: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 22 5 10 4 Fire Mode ...

Страница 26: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 23 5 10 5 Gas leakage ...

Страница 27: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 24 5 10 6 Silent panic ...

Страница 28: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 25 5 10 7POWER TEMP Emergency Current ...

Страница 29: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 26 5 10 8 Panic ...

Страница 30: ... arm vacation mode disarm and alarm 6 1 Panel Settings a Authorize the HDL MPL8 48 to arm and disarm the system in Arming Settings window of in Bypass Settings page Subnet Device ID is 1 8 b Go to HDL MPL8 48 panel configure button 1 to arm for vacation mode key mode is single on Subnet Device ID is 1 3 key type is security module parameter1 area No is 1 and parameter2 is vacation ...

Страница 31: ... and select area 1 b Go to security module s Bypass Settings page enable the alarm for index 1 2 3 input the 8in1 sensor s ID here is 1 77 and channel 1 2 3 the index No in 8in1 sensor Close the doors and make sure there is no movement in the detection range of 8in1 then refresh this page you will be able to get the normal status of these three channels in the Status column here channel1 channel2 ...

Страница 32: ...or then can select its entry delay time is two four times of Entry Delay then save e When press the arm button the senor will start to detect the status of these three channels to check whether they are in normal states or not If all of them are Close then the security will start to arm after Exit Delay If one of them is not in the normal state e g channel 1 shows OFF status the main door is still...

Страница 33: ...el inside the room 6 3 Vacation Settings 1 Before leave for vacation press the vacation mode button turn off AC and light the music player will play a voice hint After 20s Exit Delay the security module starts to arm the house a Set 20s for Exit Delay b Turn off channel 1 of relay Subnet Device ID is 1 5 and AC which is controlled by HDL MPL8 48 Subnet Device ID is 1 8 in EXIT BUZZER ON window use...

Страница 34: ...ION ARM window need to set three commands here Check the universal switch list of Z Audio 1 send universal switch 208 ON Select Audio source SD Card 2 send universal switch 150 ON Select List 150 is reserved for folder special 3 send universal switch 1 149 ON Select the number that at front of voice Here the voice hint for vacation is 001Vacation then set three commands to trigger it The ID of Z A...

Страница 35: ... morning and turn on at 20 00 turn off at 23 00 in the evening a Enable index 1 set the Start Time is 6 00 and the End Time is 7 00 b Select ON in the right side setup to turn on channel1 of relay ID is 1 5 When the time reaches 6 00 it will turn on it c Select OFF in the right side setup to turn off channel1 of relay ID is 1 5 When the ...

Страница 36: ... lights at 20 00 turn off at 23 00 in the evening 3 When there is someone opening the door then 8in1 sensor s detected status will change no movement movement dry contact connected disconnected it will report to the security module then security module will trigger to the Z Audio to play welcome home voice hint a Make sure there is one voice hint for come back in special folder of SD Card Here it ...

Страница 37: ...ess it to control 5 If it s not the house owner after 20s Entry Delay will turn to alarm After 5 minutes of alarm still not disarm stop alarm When there are more triggers from 8in1 sensor it will start to alarm again and that cycle repeats a Set 20s for Entry Delay 15s for Siren Delay 5 minutes for Reset after Alarm b Can set to trigger the alarm buzzer after 20s e g the alarm buzzer is connected ...

Страница 38: ... Delay here it s 15s if still not disarm it will trigger the targets in INDOOR SIREN ON and OUTDOOR SIREN ON After 5 minutes it will restart into the monitoring state if there are more triggers it will trigger the buzzer siren alarm and so on then realize that monitor and alarm circularly ...

Страница 39: ...SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS ...

Отзывы: