SPECIFICATIONS

TEST VOLTAGE:

500VDC or 5,000VDC nominal

TEST CURRENT:

100 microamps indicated on 5,000VDC range and
1,000 microamps indicated on 500VDC range,
2,000 microamps maximum.

BATTERY:

9V lithium or alkaline

IMPORTANT SAFETY INFORMATION 

Read and understand these instructions prior to use. These operating instructions are not
a substitute for proper training in the use of this equipment. High voltage systems present
serious hazards, including the risk of death or serious injury due to arcing, thermal burns
and electrocution. HD Electric’s products are intended solely for use by professionals with
knowledge, training and experience in the use of the equipment and its accessories in and
around high voltage systems. 

All applicable federal, state, company and OSHA work practices must be followed. If you are
unfamiliar with the work practices required, DO NOT PROCEED. Call HD Electric Company if
you have any questions regarding this equipment. 

Important labels are affixed to the
products. Read and understand each
of them before proceeding. 

The users of this device should always be
equipped with personal protective equipment
including high voltage gloves, flame retardant
clothing and eye and face protection. Some
applications may require additional protective
equipment. 

Failure to follow these and other warnings
and safety precautions may result in severe
injury or death. 

NOTICES

- This product is designed for use by professionals trained in its use and application

in and around high voltage electrical equipment. If you are not trained in the work methods
required for safe operation, do not proceed until you obtain the training. 

CAUTIONS

- This product was tested before leaving the factory but it must be inspected prior

to and after each use for proper working condition. If any defect or condition is noted, do not
use this product. Remove from service and arrange for repair. 

WARNINGS

- Rigorous hot stick work precautions and all OSHA and company work

practices must be followed. Always wear approved cover-up and safety equipment.
Read and understand instructions prior to use. Misuse and abuse of this product can
lead to severe injury or death.

Содержание PT-5000W

Страница 1: ...Operating Instruction Manual PT 5000W PORTABLE DUAL HIGH VOLTAGE TESTER 1475 Lakeside Drive Waukegan Illinois 60085 U S A 847 473 4980 fax 847 473 4981 website www HDElectricCompany com ...

Страница 2: ...er selectable 500VDC or 5 000VDC The output is current limited to two milliamps maximum for safety The tester is turned on by pressing and holding a single pushbutton for 500VDC or two buttons for 5 000VDC The buttons are mechanically guarded to prevent accidental operation The front panel has indicators for each voltage range When only the left button is pressed an amber light turns on indicating...

Страница 3: ...either 100 or 1 000 microamps depending on the voltage range selected Equipment with a substantial capacitance such as long cables or power factor correction capacitors may indicate leakage current when first energized If the equipment is in good condition these leakage current indications will disappear as the equipment is charged APPLICATIONS The PT 5000W is a general purpose insulation tester f...

Страница 4: ...4 from primaries to secondaries primary to ground on two bushing transformer secondaries to ground center tap must be ungrounded one bushing to ground across two bushings one bushing ...

Страница 5: ...of the built in 30 second time limit capacitors tested in this manner can only be charged up to 500VDC and should only be tested with the 500VDC range Remember that the tester requires up to 2 minutes to fully discharge a charged capacitor and should remain connected for that time UndergroundApplications Underground insulation systems include a wide variety of cable and equipment and almost any in...

Страница 6: ...elsareaffixedtothe products Readandunderstandeach ofthembeforeproceeding Theusersofthisdeviceshouldalwaysbe equippedwithpersonalprotectiveequipment includinghighvoltagegloves flameretardant clothingandeyeandfaceprotection Some applicationsmayrequireadditionalprotective equipment Failuretofollowtheseandotherwarnings andsafetyprecautionsmayresultinsevere injuryordeath NOTICES Thisproductisdesignedfo...

Страница 7: ...7 ...

Страница 8: ...ete unavailable over time end of life In the event that a Product cannot be repaired or replaced due to unavailability of parts HD Electric Company will use commercially reasonable efforts to obtain substitute parts or conduct work around design but cannot guarantee its ability to do so Items not found defective will be returned at your expense or failing receipt of instruction from you on return ...

Отзывы: