2. SPECIFICATION
2.1 Performance data of Swimming Pool Heat Pump Unit
**** REFRIGERANT: R410A
UNIT
PASHW030-P
PASHW045-P
Heating Capacity
Kw
14.7
23.4
Btu/h
50 000
80 000
Heating Power Input
kw
2.1
3.6
Running Current
A
10.2
16
Power Supply
208-230V-/60Hz
208-230V-60Hz
Compressor Quantity
1
1
Compressor
Rotary
Scroll
Fan Number
1
1
Fan Power Input
W
120
180
Fan Rotate Speed
RPM
850
850
Fan Direction
Horizontal
Horizontal
Noise
dB(A)
54
56
Water Connection
inch
1
1.5
Water Flow Volume
gal/min
30
36
Water Pressure Drop (max)
kPa
10
10
Unit Net Dimensions (L/W/H)
inch
See the drawing of the unit
Unit Ship Dimensions (L/W/H)
inch
See package label
Net Weight
See nameplate
Shipping Weight
See package label
Heating : Ambient temp. (DB/WB) : 80.6°F / 71.2°F, Inlet water temp: 80°F
Heating mode : Ambient temp. Operating envelope 45°F - 95°F
2