H B X   Z O N - 0 6 0 0   Z o n e   C o n t r o l

V e r s i o n   1 . 0 . 0

 Page 1

 

 

 

RELAYS

240VAC 5A Max

 

INPUT

120VAC 15A Max

ZON-0600

ZONE CONTROLLER

Zone 2

LIVING ROOM

Floor

79°

F

Humidity

30

Target

72°

F

72

.0

°F

10:00

am

Outdoor

10°

F

Zone 1

DHW

Target

130°

F

128

.0

°F

10:00

am

Outdoor

10°

F

100%

9:41 AM

Home

Cabin

10°F

Locations

68

118

°F

°F

DHW

Room Temp

None

Target

45

50

°F

°F

SNOWMELT

Room Temp

MELT

Target

72

74

°F

°F

LIVING ROOM

Room Temp

1

2

3

Target

75

72

°F

°F

BASEMENT

Room Temp

Target

64

65

°F

°F

BEDROOM

Hot Tank

Cold Tank

HBX ZON-0600 ZONE MODULE

HBX Control Systems

 launches the latest generation of 

the Wi-Fi Zoning System: the ZON-0600. This revolutionary 
control allows you to customize exactly your needs and 

wants for any application including radiant floor and 

forced air system control or a combination of both. 

The 

ZON-0600

 can operate zone valves or zone pumps 

the choice is yours. Each module allows control up to 
4 additional zones with the ability of wireless expansion 
between modules. 
Each controller is now Wi-Fi enabled eliminating the 
need to use the an external Wi-Fi module for online 

connection. Each zone can be viewed or configured 

from your smartphone or tablet devices, allowing you 
to control your comfort anytime or anywhere.

There are so many features integrated into the 

ZON-

0600

 which allows for customized options including 

selectable pump and demand outputs, pre and post 
purge run times with exercising options, and the ability 
to tie in an auxiliary thermistor to run a setpoint directly 
off the 

ZON-0600.

 Each ZON-0600 can run one (1) fan 

coil each with humidity.

This control can also function as a stand alone system 

without WiFi capabilities.

FEATURES

•  App for Android or Apple Smartphone/tablet 

device for remote access with alarm email 

notification

•  Control up to four (4) independent zones per 

control plus one Fancoil (W-Y-G) output 

•  Humidity Control (X Output) 

•  Wirelessly expandable to a maximum of twenty 

(20) zones within distance

•  Provides pump, valve or damper control 

•  Three (3) demands outputs (TT1, TT2, TT3)

•  4 pipe geo systems 

Содержание ZON-0600

Страница 1: ...HBX Control Systems Inc Installation Manual ZON 0600 Version 1 0 0 ZON 0600 Zone Control...

Страница 2: ...Table of Contents TABLE OF CONTENTS Introduction 1 3 Description 1 Safety Symbols Warnings 2 Receipt Inspection 2 Technical Data and Dimensions 3 Wiring Installation 4 25 Wiring 4 Installation 5 Main...

Страница 3: ...nal zones with the ability of wireless expansion between modules Each controller is now Wi Fi enabled eliminating the need to use the an external Wi Fi module for online connection Each zone can be vi...

Страница 4: ...e harm For more information go to www P65Warnings ca gov WARNING a Use copper conductors only if the terminal is acceptable only for connections to copper wire b Use aluminum conductors only or use al...

Страница 5: ...AC 5A or 24VAC 5A Input 120VAC 15A Max or 24VAC 5A 2 x Pump Relay 120VAC 5A 1x Auxiliary input 24VAC 2A Thermistor Combined relay power should not exceed 15A Weight 0 75 kg Dimensions 131mm W x 246mm...

Страница 6: ...WER 120 17 N L 16 15 0 4 3 I TT1 0 6 5 I TT2 5 TH1 10 9 6 5 12 11 6 5 14 13 6 5 16 15 6 2 Y G 20 19 2 X 21 2 5A 1 PUMP 1 1 2 1 1 PUMP 2 3 4 1 5A HBX ZON 0600 Zone Control N ZN 1 7 8 H N 9 10 H ZN 2 N...

Страница 7: ...are using a single thermostat ensure it is connected to TH1 on the control It is normal for the thermostat to take up to two 2 minutes to startup The THM 0600 should not be installed in a high humidi...

Страница 8: ...oor Temp or Aux temperature for a displayed only temp When the setpoint is being used the actual temp will be displayed in blue on the left and the target will be on the right When the Auxiliary setpo...

Страница 9: ...he connected thermostat to the associated zone If no thermostat is connected to a zone that zone will not be displayed Secondary Zone Sync code of any LINKED ZON 0600 s to this primary ZON 0600 This w...

Страница 10: ...call DEMAND SELECTIONS HD Low Temp Heat demand low temperature such as radiant in floor HD2 High Temp Heat demand high temperature such as a fancoil or baseboard heaters 2nd stage fan coil AUX Aux Se...

Страница 11: ...be delayed to run after the call associated with it has been activated Pump Exercise Time 0 240 hours the amount of time that need to pass before the pumps will exercise the system pumps 0 no exercisi...

Страница 12: ...input this network exactly how it would appear including spaces numbers capital or lowercase letters and or special characters Wi Fi SSID Scan Pressing this will allow the ZON 0600 to actively scan fo...

Страница 13: ...at Sun Time Zone Select the time zone for your area STANDARD TIMEZONES DAYLIGHT SAVINGS Atlantic Standard Time AST GMT 4 Eastern Standard Time EST GMT 5 Central Standard Time CST GMT 6 Mountain Standa...

Страница 14: ...and then shut off at 124 Priority Shield None 1 7 Priority for this Auxiliary Thermistor Shield not affected by another zones priority None No priority for this zone any other zone with priority will...

Страница 15: ...for the zone outputs to run after the call associated with it has been removed DAMPER COMMUNICATION On Off Communication between ZON 0600 s in respect to dampers associated with one fancoil For exampl...

Страница 16: ...2 stage N O they take over the next zone output for example the THM 1 is set to 2 stage N O then the damper operates on the zone 2 output also the THM 2 thermostat output will switch off and if a ther...

Страница 17: ...stat 1 2 1 1 DO NOT CONNECT POWER HERE INT ROOM EXT ROOM HBX TH TH Fancoil R W Y G C C X Humidity Device System Pump 1 THM 0600 3 COMM 6 5 3 TH 2 TH 4 3 2 Thermostat 1 2 1 1 DO NOT CONNECT POWER HERE...

Страница 18: ...INT ROOM EXT ROOM HBX TH TH THM 0600 3 COMM 6 5 3 TH 2 TH 4 3 2 Thermostat 1 2 1 1 DO NOT CONNECT POWER HERE INT ROOM EXT ROOM HBX TH TH Fancoil R W Y G C DHW Sensor Not included with ZON 0600 can use...

Страница 19: ...ancoil Outputs EXT THM TH2 TH3 TH4 Aux Therm Input Actuators 2 3 4 1 C R L N 120 VAC 24 VAC TT2 Cold Demand TT1 Heat Demand Zone 1 Zone 2 Zone 3 Zone 4 THM 0600 3 COMM 6 5 3 TH 2 TH 4 3 2 Thermostat 1...

Страница 20: ...2 1 1 DO NOT CONNECT POWER HERE INT ROOM EXT ROOM HBX TH TH THM 0600 3 COMM 6 5 3 TH 2 TH 4 3 2 Thermostat 1 2 1 1 DO NOT CONNECT POWER HERE INT ROOM EXT ROOM HBX TH TH Fancoil R W Y G C DO NOT CONNEC...

Страница 21: ...600 3 COMM 6 5 3 TH 2 TH 4 3 2 Thermostat 1 2 1 1 DO NOT CONNECT POWER HERE INT ROOM EXT ROOM HBX TH TH THM 0600 3 COMM 6 5 3 TH 2 TH 4 3 2 Thermostat 1 2 1 1 DO NOT CONNECT POWER HERE INT ROOM EXT RO...

Страница 22: ...ZONE POWER 5A 5A 5A 5A 1 2 1 1 W R Fancoil Outputs 0 8 7 I TT3 Demand Outputs 1 18 17 1 Thermostat Signal Communication Fancoil Outputs EXT THM TH2 TH3 TH4 Aux Therm Input Damper 5 Zone 5 Radiant C R...

Страница 23: ...Humidity Device System Pump 1 THM 0600 3 COMM 6 5 3 TH 2 TH 4 3 2 Thermostat 1 2 1 1 DO NOT CONNECT POWER HERE INT ROOM EXT ROOM HBX TH TH DO NOT CONNECT POWER HERE GR POWER 120 17 N L 16 15 0 4 3 I T...

Страница 24: ...odules are controlling the same system pump then the system pump outputs should be wired in parallel Check priorities settings Fancoil outputs won t turn on Verify wiring Check the demand settings See...

Страница 25: ...ole remedy shall be at HBX s option repair or replacement The foregoing warranties and remedies are exclusive and in lieu of all other warranties expressed or implied either in fact or by operation of...

Страница 26: ...H B X Z O N 0 6 0 0 Z o n e C o n t r o l V e r s i o n 1 0 0 Page 24 NOTES...

Страница 27: ...H B X Z O N 0 6 0 0 Z o n e C o n t r o l V e r s i o n 1 0 0 Page 25 NOTES...

Страница 28: ...ems Inc 2021 Toll Free Technical Support 1 855 410 2341 Phone 1 403 720 0029 Fax 1 403 720 0054 Email info hbxcontrols com Web www hbxcontrols com HBX Control Systems Inc 4516 112th Avenue SE Calgary...

Отзывы: