25
©HBS Bolzenschweiss-Systeme GmbH & Co. KG
All rights reserved – Reprinting, in whole or in part, only with the approval of the manufacturer
13 Maintenance and Care
13.2 Inspection and Tests
Inspect the chuck before every use.
Replace the chuck if you discover signs of burning on the welding element and/or
on the chuck.
Work here in accordance with
point 10.1 „Mounting the chuck“
in this manual.
Before every use, inspect the bellows on the front part of the stud welding gun for
proper seating and/or damage.
Never work with damaged or incorrectly seated bellows
.
This will contribute to a long service life of your stud welding gun.
Inform your dealer or maintenance department if you discover any dama-
ge.
Before every use, check that the type designations and adjustment aids on the
stud welding gun are still legible.
Clean the type plates in the event of soiling.
Replace any type plates that are damaged or no longer legible.